It is particularly important to reach operating
temperature as quickly as possible on days
when the flue pipe draught is not ideal due to
unfavourable wind and weather conditions.
Ensure that the fuel ignites as quickly as possible.
Practical tip: Cut the wood into much smaller
pieces and use an additional fire bait.
If the stove has not been used for some time, it is
important to check the flue pipe for obstructions.
6.9 SWITCHING OFF THE STOVE
To turn the stove off, proceed as described below:
STEP
ACTION
Wait for the flame and embers to be
1
completely extinguished
When there is no flame and the bed
2
of embers no longer releases heat,
close the air valve completely
7 MAINTENANCE
7.1 SAFETY WARNINGS FOR
MAINTENANCE
Maintenance of the appliance must be performed
at least once a year and should be planned in
advance with the Technical Assistance Service.
In some conditions, such as turning the stove
on and off or inappropriate use, the combustion
products can contain small soot particles that
build up in the smoke evacuation system. This
can reduce the cross-section of the smoke duct
and pose a fire risk. The smoke evacuation
system must be inspected and cleaned at least
once a year.
The maintenance operations must be carried out
when the stove is cold.
Before completing any maintenance operation,
adopt the following precautions:
• Make sure that all parts of the appliance are
cold.
• Make sure that the ashes are completely cold.
• Always
operate
appropriate for maintenance.
• When maintenance is finished, re-install all
of the dis-assembled parts before restarting
operation.
The quality of the wood, the appliance operating
mode and combustion control can affect
maintenance activity frequency.
7.2 CLEANING
Perform the cleaning operations so as to
guarantee correct appliance operation.
The table below lists the necessary cleaning
operations
required
operation.
PARTS /
FREQUENCY
Combustion
chamber
Grate for ash
Ash drawer
Glass
Extraction duct
In the first periods of use, carry out cleaning
operations frequently to understand the
right frequency of intervention, which varies
depending on the installation, use, wood used,
etc.
The stove can be cleaned with a dry, lint-free
cloth.
Before cleaning and brushing, the smoke baffle
plates must be removed by gently lifting the
plates and removing the pins.
With daily use, make sure the gaskets are intact
and ensure that they are replaced before they
leak.
Always remember to ventilate the room after
repairs to painted surfaces and the use of care
products.
Once a year, or more, according to national and
ENGLISH
with
equipment
that
for
correct
appliance
1
2 -3
60/90
DAY