Télécharger Imprimer la page

Ferroli FORCE W Serie Instructions D'utilisation, D'installation Et D'entretien page 223

Masquer les pouces Voir aussi pour FORCE W Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 254
FORCE W
- Parameters
Each system requires a different parameterization. Follow the access procedure given below.
"Configuration - Parameters Menu"
Check/Change parameter b02 of the "Configuration - Parameters Menu" to 9.
Check/Change parameter b08 of the "Configuration - Parameters Menu" to 1.
Check/Change parameter b04, b05 and b06 of the "Configuration - Parameters Menu" according to the values given
in the table *** 'Configuration - Parameters Menu' on page 232 ***.
- Parameters FZ4B
See relevant manual in Kit.
- Optional functions
As well as the electrical connections of the previous figure (required for this system configuration) there are options that
do not require settings.
Fault indication (voltage-free contact output): the example shows the connection of a lamp at 230Vac
301
Remote reset input (230Vac): the example shows the connection of a double-pole switch at 230Vac, allowing the resetting of a
302
block type fault
Fault indication (230Vac): the example shows the connection of a lamp at 230Vac
357
EN
1
2
3
4
5
6
7
8
L
N
302
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
37 38 39 40 41 42 43 44
cod. 3541Q764 - Rev. 00 - 05/2021
9 10 11 12 13 14 15 16 17 18
301
357
N
fig. 51
L
223

Publicité

loading

Ce manuel est également adapté pour:

Force w 60Force w 80Force w 99Force w 120Force w 150