FORCE W
- Parameters
Each system requires a different parameterization. Follow the access procedure given below.
"Configuration - Parameters Menu"
Check/Change parameter b02 of the "Configuration - Parameters Menu" to 9.
Check/Change parameter b08 of the "Configuration - Parameters Menu" to 1.
Check/Change parameter b04, b05 and b06 of the "Configuration - Parameters Menu" according to the values given
in the table *** 'Configuration - Parameters Menu' on page 232 ***.
- Parameters FZ4B
See relevant manual in Kit.
- Optional functions
As well as the electrical connections of the previous figure (required for this system configuration) there are options that
do not require settings.
Fault indication (voltage-free contact output): the example shows the connection of a lamp at 230Vac
301
Remote reset input (230Vac): the example shows the connection of a double-pole switch at 230Vac, allowing the resetting of a
302
block type fault
Fault indication (230Vac): the example shows the connection of a lamp at 230Vac
357