Télécharger Imprimer la page
Ferroli FORCE W Serie Instructions D'utilisation, D'installation Et D'entretien
Ferroli FORCE W Serie Instructions D'utilisation, D'installation Et D'entretien

Ferroli FORCE W Serie Instructions D'utilisation, D'installation Et D'entretien

Masquer les pouces Voir aussi pour FORCE W Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 254

Liens rapides

FORCE W
ISTRUZIONE PER L'USO L'INSTALLAZIONE E LA MANUTENZIONE
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
INSTRUC IUNI DE UTILIZARE, INSTALARE I ÎNTRETINERE
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
ТЕХНИЧЕСКИЙ ПАСПОРТ ИЗДЕЛИЯ
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ, МОНТАЖУ ИТЕХОБСЛУЖИВАНИЮ
INSTRUKCJA OBS UGI, INSTALACJI I KONSERWACJI
,

Publicité

loading

Sommaire des Matières pour Ferroli FORCE W Serie

  • Page 1 FORCE W ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO INSTRUC IUNI DE UTILIZARE, INSTALARE I ÎNTRETINERE INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN ТЕХНИЧЕСКИЙ ПАСПОРТ ИЗДЕЛИЯ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ, МОНТАЖУ ИТЕХОБСЛУЖИВАНИЮ INSTRUKCJA OBS UGI, INSTALACJI I KONSERWACJI...
  • Page 2 FORCE W • Leggere attentamente le avvertenze contenute in questo li- spetto di quanto sopra può compromettere la sicurezza bretto di istruzioni in quanto forniscono importanti indicazioni dell’apparecchio. riguardanti la sicurezza di installazione, l’uso e la manuten- • Per garantire il buon funzionamento dell’apparecchio è indi- zione.
  • Page 3 FORCE W 1 Istruzioni d’uso ........................4 1.1 Presentazione ............................4 1.2 Pannello comandi........................... 4 1.3 Accensione e spegnimento ........................8 1.4 Regolazioni............................. 9 2 Installazione ........................... 19 2.1 Disposizioni generali ..........................19 2.2 Luogo d’installazione ..........................19 2.3 Collegamenti idraulici ........................... 19 2.4 Collegamento gas ..........................
  • Page 4 1.1 Presentazione Gentile cliente, La ringraziamo di aver scelto FORCE W, una caldaia murale FERROLI di concezione avanzata, tecnologia d’avanguar- dia, elevata affidabilità e qualità costruttiva. La preghiamo di leggere attentamente il presente manuale perchè fornisce importanti indicazioni riguardanti la sicurezza di installazione, uso e manutenzione.
  • Page 5 FORCE W Tasti diretti I tasti diretti (part. 8, 9, 10 - fig. 1) hanno sempre la stessa funzione. Tasti navigazione/menù I tasti navigazione/menù (part. 5, 6, 7, 11, 12, 13 - fig. 1) servono per navigare tra i vari menù implementati nel pannello di controllo.
  • Page 6 FORCE W MANUTENZIONE Vedi fig. 59 Modalità Test Vedi fig. 56 Modalità Test Selezione Tipo Gas Vedi Modalità Test Cascata Vedi “Informazione Service” a pag. 16 Informazione Service Vedi “Data Intervento Service” a pag. 16 Data Intervento Service IMPOSTAZIONI Vedi fig. 7 Lingua Unità...
  • Page 7 FORCE W Esclusione bollitore (economy) Il riscaldamento/mantenimento in temperatura del bollitore può essere escluso dall'utente. In caso di esclusione, non vi sarà erogazione di acqua calda sanitaria. Il bollitore può essere disattivato dall’utente (modalità ECO) premendo il tasto eco/comfort (part. 10 - fig. 1). In modalità ECO il display attiva il simbolo .
  • Page 8 FORCE W 1.3 Accensione e spegnimento Accensione caldaia Premere il tasto d’accensione/spegnimento (part 14 - fig. 1). Display v.0X Centralina Modulo 1 v.XX fig. 7 - Accensione caldaia Premendo il tasto contestuale 1 è possibile scegliere la lingua desiderata e confermarla attraverso il tasto “OK”. Premendo il tasto contestuale 3 è...
  • Page 9 FORCE W Raggiungere la schermata visualizzata in fig. 9 navigando nel menù seguendo il percorso “MENÙ UTENTE “Impos- tazioni” “Impostazione Orario”. Premere i tasti navigazione 5 e 7 per selezionare il valore e modificarlo con i tasti contestuali 1 e 2. Confermare con il tasto OK. Impostazione orario : 59 per selezionare...
  • Page 10 FORCE W Per disattivare la modalità Estate, premere nuovamente il tasto (part. 9 - fig. 1) per 1 secondo. 23°C 32°C Giovedì 9 Gen. 2014 11:33:03 fig. 11 - Estate Regolazione temperatura riscaldamento Accedere al menù “Temp Regolazione” per variare la temperatura da un minimo di 20°C ad un massimo di 80°. Con- fermare con il tasto OK.
  • Page 11 FORCE W Regolazione Riduzione temperatura sanitario (con bollitore opzionale installato) Accedere al menù “Temp Regolazione” per variare la temperatura da un minimo di 10°C ad un massimo di 65°C. Con- fermare con il tasto OK. Temp Regolazione per confermare fig. 14 La caldaia viene venduta con programma orario non attivato.
  • Page 12 FORCE W Programmazione orario La programmazione dell’orario avviene con le stesse modalità sia per il riscaldamento che per il sanitario; i due progra- mmi sono indipendenti. Per la programmazione del Riscaldamento accedere al menù “Programma Orario” seguendo il percorso “MENÙ UTENTE “RISCALDAMENTO”...
  • Page 13 FORCE W Premere il tasto di navigazione 7 per posizionarsi sull’orario di fine della prima fascia oraria (fig. 19) e impostarlo sul valore desiderato tramite i tasti contestuali 1 e 2. Programma Orario 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Page 14 FORCE W Programma Orario 06:00 - 16:00 16:00 - 21:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copia su giorno successivo Salva & Esci per confermare fig. 22 Programma Orario 06:00 - 16:00 16:00 - 21:00 21:00 - 06:00 --:-- - --:-- --:-- - --:--...
  • Page 15 FORCE W Programmazione Legionella (con bollitore opzionale installato) Per abilitare la Funzione Antilegionella è necessario settare il parametro P23, all’interno del “MENÙ TECNICO, su Per programmare la funzione è necessario accedere al menù “Legionella” attraverso il percorso “MENÙ UTENTE “ACQUA CALDA SANITARIA” “Legionella”.
  • Page 16 FORCE W Funzione Vacanze Accedere al menù “FUNZIONE VACANZA” attraverso il percorso “MENÙ UTENTE “FUNZIONE VACANZA” per po- ter impostare: • Data inizio Vacanza. • Data fine Vacanza. Il display può attivare due tipi di icone: • - La funzione Vacanze é programmata ma non ancora attiva. •...
  • Page 17 FORCE W Regolare lo spostamento parallelo delle curve da 20 a 60 °C (fig. 30), attraverso il parametro “Offset1” e confermare con il tasto OK. Offset 1 per confermare fig. 28 - Spostamento parallelo delle curve Se la temperatura ambiente risulta inferiore al valore desiderato si consiglia di impostare una curva di ordine superiore e viceversa.
  • Page 18 FORCE W Regolazioni da cronocomando remoto Se alla caldaia è collegato il Cronocomando Remoto (opzionale), le regolazioni descritte in precedenza ven- gono gestite secondo quanto riportato nella tabella 1. Tabella 1 La regolazione può essere eseguita sia dal menù del Cronocomando Remoto sia dal panne- Regolazione temperatura riscalda- llo comandi caldaia.
  • Page 19 FORCE W 2. Installazione 2.1 Disposizioni generali L'INSTALLAZIONE DELLA CALDAIA DEVE ESSERE EFFETTUATA SOLTANTO DA PERSONALE SPECIALIZZATO E DI SICURA QUALIFICAZIONE, OTTEMPERANDO A TUTTE LE ISTRUZIONI RIPORTATE NEL PRESENTE MA- NUALE TECNICO, ALLE DISPOSIZIONI DI LEGGE VIGENTI, ALLE PRESCRIZIONI DELLE NORME NAZIONALI E LOCALI E SECONDO LE REGOLE DELLA BUONA TECNICA.
  • Page 20 FORCE W Circolatore ad alta efficienza (opzionale) L'impostazione di fabbrica é idonea per tutte le installazioni; tuttavia, è possibile impostare, tramite il selettore di velocità (vedi fig. 32), una strategia di funzionamento diversa in funzione delle caratteristiche dell'impianto. 1 2 3 fig.
  • Page 21 FORCE W Caratteristiche dell’acqua impianto Prima di procedere all'installazione del generatore FORCE W, l'impianto, nuovo o esistente, deve essere opportuna- mente pulito allo scopo di eliminare residui installativi, solventi, fanghi e contaminanti in genere che possano precludere l'efficacia dei trattamenti condizionanti di protezione. Utilizzare prodotti di pulizia neutri non aggressivi verso metalli, gomma e parti in plastica del generatore/impianto.
  • Page 22 FORCE W Verificare sempre la concentrazione di prodotto dopo ogni inserimento e ciclica- mente, almeno una volta all'anno avvalendosi di personale tecnico qualificato qua- le la nostra rete di assistenza tecnica autorizzata. Tabella 2 - Condizionanti chimici dichiarati idonei e disponibili presso la nostra rete di Centri Assis- tenza Tecnica Autorizzata Descrizione Prodotti alternativi tipo Sentinel...
  • Page 23 FORCE W Kit opzionali A richiesta sono disponibili i seguenti kit: cod. 042070X0 - KIT CIRCOLATORE ad ALTA EFFICIENZA - 7m. (A - fig. 36) cod. 042071X0 - KIT CIRCOLATORE ad ALTA EFFICIENZA - 10m. (A - fig. 36) cod. 042072X0 - KIT IDRAULICO Nel Kit 042072X0 sono contenuti: VALVOLA DI NON RITORNO - Femmina 1”1/2 (B - fig.
  • Page 24 FORCE W Esempi circuiti idraulici Negli esempi descritti in seguito potrebbe essere richiesto di verificare/modificare alcuni parametri. Per fare questo è necessario accedere al menù Tecnico. Dalla schermata principale (Home), premere il tasto Menù principale (part. 12 - fig. 1). Accedere al menù...
  • Page 25 FORCE W Due circuiti riscaldamento diretti - Schema di principio fig. 41 - Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 fig.
  • Page 26 FORCE W Legenda (fig. 41 - fig. 42) Termostato ambiente 1a zona (diretta) 1a zona (diretta) Termostato ambiente 2a zona (diretta) 2a zona (diretta) Sonda esterna Mandata Circolatore 1a zona (diretta) Ritorno Circolatore 2a zona (diretta) Dispositivi di sicurezza ISPESL (Quando richiesti - non forniti) Per gestire la temperatura scorrevole è...
  • Page 27 FORCE W Un circuito riscaldamento diretto ed un circuito sanitario con circolatore - Schema di principio fig. 44 - Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44...
  • Page 28 FORCE W Legenda (fig. 44 - fig. 45) Termostato ambiente 1a zona (diretta) 1a zona (diretta) Circolatore bollitore Circuito bollitore Sonda esterna Mandata Sonda bollitore Ritorno Circolatore antilegionella Circolatore 1a zona (diretta) Dispositivi di sicurezza ISPESL (Quando richiesti - non forniti) Per gestire la temperatura scorrevole è...
  • Page 29 FORCE W Un circuito riscaldamento diretto ed un circuito sanitario con valvola deviatrice (a 3 fili) - Schema di principio Utilizzare valvole deviatrici a 3 fili: - FASE APERTURA 230V - FASE CHIUSURA 230V - NEUTRO con tempi di commutazione (da tutto chiuso a tutto aperto) non superiori a 90 secondi. fig.
  • Page 30 FORCE W Legenda (fig. 46 - fig. 47) Circolatore riscaldamento 1a zona (diretta) Termostato ambiente 1a zona (diretta) Circuito bollitore Sonda esterna Mandata Sonda bollitore Ritorno Valvola a 3 vie (a tre fili) A = FASE APERTURA B = NEUTRO C = FASE CHIUSURA Dispositivi di sicurezza ISPESL (Quando richiesti - non forniti) Per gestire la temperatura scorrevole è...
  • Page 31 FORCE W Due circuiti riscaldamento miscelati, un circuito riscaldamento diretto e un circuito sanitario con circolatore - Schema di principio La scheda controllo zone FZ4B può gestire diverse tipologie d’impianto. Quello riportato è un esempio. Utilizzare valvole deviatrici a 3 fili: - FASE APERTURA 230V - FASE CHIUSURA 230V - NEUTRO...
  • Page 32 FORCE W - Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo. fig. 50 Legenda Termostato ambiente 1a zona (miscelata) Termostato di sicurezza 1a zona (miscelata) 317a Termostato ambiente 2a zona (miscelata) Termostato di sicurezza 2a zona (miscelata)
  • Page 33 FORCE W - Parametri Ogni impianto necessita di una diversa parametrizzazione. Seguire la procedura d’accesso riportata di seguito. “Menù Parametri - Configurazione” Verificare/Modificare parametro b02 del “Menù Parametri - Configurazione” a 9. Verificare/Modificare parametro b08 del “Menù Parametri - Configurazione” a 1. Verificare/Modificare parametro b04, b05 e b06 del “Menù...
  • Page 34 FORCE W 2.4 Collegamento gas Prima di effettuare l’allacciamento, verificare che l’apparecchio sia predisposto per il funzionamento con il tipo di combustibile disponibile ed effettuare una accurata pulizia di tutte le tubature gas dell’impianto, per rimuovere eventuali residui che po- trebbero compromettere il buon funzionamento della caldaia.
  • Page 35 FORCE W tuata tramite collegamento diretto dalla rete o tramite pile, a seconda del tipo di dis- positivo. Sonda esterna (optional) Collegare la sonda ai rispettivi morsetti. La massima lunghezza consentita del cavo elettrico di collegamento caldaia – sonda esterna è di 50 m. Può essere usato un comune cavo a 2 conduttori. La sonda esterna va installata preferibil- mente sulla parete Nord, Nord-Ovest o su quella su cui si affaccia la maggioranza del locale principale di soggiorno.
  • Page 36 FORCE W In caso di carichi con assorbimenti maggiori é necessario installare dei relé di appoggio con relative protezioni supplementari. 2.6 Condotti fumo LE CALDAIE DEVONO ESSERE INSTALLATE IN LOCALI CHE RISPONDONO AI REQUISITI DI AEREAZIONE FONDAMENTALI. IN CASO CONTRARIO SUS- SISTE PERICOLO DI ASFISSIA O DI INTOSSICAZIONE.
  • Page 37 FORCE W Tabella 4 Tabella accessori MODELLI FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 Massima prevalenza consentita (Pa) TUBO 1 M m/f 11,9 16,0 24,5 TUBO 0.5 M m/f 12,3 CURVA 90° Ø80 CURVA 45°...
  • Page 38 FORCE W 2.7 Collegamento scarico condensa AVVERTENZE La caldaia è dotata di sifone per lo scarico condensa. Seguire le seguenti istruzioni per effettuare il montaggio. 1. Fissare il sifone. 2. Prima di collegare il tubo flessibile all’impianto di scarico, riempire il sifone con dell’acqua. 3.
  • Page 39 Personale Qualificato e di sicura qualificazione (in possesso dei requisiti tecnici professionali previsti dalla normativa vigente) come il personale del Servizio Tecnico Assistenza Clienti di Zona. FERROLI declina ogni responsabilità per danni a cose e/o persone derivanti dalla manomissione dell’apparecchio da parte di persone non qualificate e non autorizzate.
  • Page 40 FORCE W fig. 57 - Modelli FORCE W 60 e FORCE W 80 fig. 58 - Modelli FORCE W 99, FORCE W 120 e FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 41 FORCE W Attivazione modalità TEST Raggiungere la schermata visualizzata in fig. 59 navigando nel menù seguendo il percorso “MENÙ UTENTE nutenzione Modalità Test Modalità test”. La caldaia si accende raggiungendo il massimo della potenza di riscaldamento (Range Rated), impostata come al pa- ragrafo successivo, in maniera graduale.
  • Page 42 FORCE W Diagramma regolazione portata termica A = kW - B = Parametro Scheda Elettronica fig. 60 MENÙ TECNICO L’ACCESSO AL MENÙ SERVICE E LA MODIFICA DEI PARAMETRI PUÒ ESSERE EFFETTUATA SOLO DA PER- SONALE QUALIFICATO. L’accesso al Menù Tecnico è possibile solo dopo aver digitato il codice 4 1 8. Ed è valido per 15 minuti. Menù...
  • Page 43 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Parametro Descrizione Range OFF=Disattivato, Sensore fumi ON=Abilitato Non implementato Massima Temperatura Fumi 0-125 °C Selezione tipo ventilatore Tempo funzionamento antiblocco 0-20 secondi pompa Note 1. I parametri che presentano più di una descrizione variano il proprio funzionamento e/o range in relazione all’impos- tazione del parametro riportato tra parentesi.
  • Page 44 FORCE W FORCE W FORCE W FORCE FORCE W FORCE Parametro Descrizione Range W 99 W 150 Con B02 = 7 - Non implementato Con B02 = 8 - Set point primario 70° ÷ 85° 80° 80° 80° 80° 80° Con B02 = 9 - Set point primario 70°...
  • Page 45 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Parametro Descrizione Range Funzione caricamento impianto OFF = Disabilitato, ON = Abilitato P.10 2/3 = 2 o 3 fili Selezione valvola 3 vie P.11 2 = 2 fili 0-10Vdc Tensione riscaldamento 0,1-10 Vdc P.12...
  • Page 46 FORCE W PUÒ SUSSISTERE PERICOLO DI SHOCK ELETTRICO O ALLAGAMENTO DEL LOCALE. Verifiche durante il funzionamento • Accendere l’apparecchio come descritto nella . • Assicurarsi della tenuta del circuito del combustibile e degli impianti acqua. • Controllare l’efficienza del camino e condotti aria-fumi durante il funzionamento della caldaia. •...
  • Page 47 FORCE W • verifica tenuta impianti acqua e gas • verifica corretta e stabile pressione di alimentazione del gas alla centrale (20 mbar per funzionamento con gas me- tano); eventuali oscillazioni o cadute di pressione sotto il valore dichiarato possono creare malfunzionamenti, arresti con esigenza di riarmo manuale.
  • Page 48 FORCE W Manutenzione straordinaria e sostituzione componenti Sostituzione elettrodo Pulizia scambiatore 3.4 Risoluzione dei problemi cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 49 FORCE W Diagnostica La caldaia è dotata di un avanzato sistema di autodiagnosi. Nel caso di un’anomalia alla caldaia, il display si illumina indicando il codice dell’anomalia e, in caso di collegamento in cascata, il numero del modulo. • Vi sono anomalie che causano blocchi permanenti che possono essere ripristinate premendo il tasto OK per un se- condo oppure attraverso il tasto RESET del cronocomando remoto (opzionale) se installato.
  • Page 50 FORCE W Codice Anomalia Possibile causa Soluzione anomalia Indicazione sovra tem- peratura sensore ritorno circolazione dell'acqua impianto insufficiente verificare circolazione acqua (Visualizzabile solo neò Menù History) Sensore danneggiato Anomalia sensore ris- caldamento 1 (man- Cablaggio in corto circuito Verificare il cablaggio o sostituire il sensore data) Cablaggio interrotto Sensore danneggiato...
  • Page 51 FORCE W Codice Anomalia Possibile causa Soluzione anomalia Sensore danneggiato Anomalia Sensore di Cablaggio in corto circuito Verificare il cablaggio o sostituire il sensore temperatura cascata Cablaggio interrotto Protezione per diffe- Verificare circolazione acqua caldaia/impianto renza temperatura > di Insufficiente circolazione in caldaia 18°tra sensore mandata Verificare integrità...
  • Page 52 FORCE W 4. Caratteristiche e dati tecnici Legenda figure cap. 4 Entrata gas - Ø 1” Mandata impianto - Ø 1” 1/2 Ritorno impianto - Ø 1” 1/2 Valvola di sicurezza Ventilatore Circolatore riscaldamento (non fornito) Sensore temperatura riscaldamento Sfiato aria automatico Valvola gas Termostato ambiente (non fornito) Secondo Termostato ambiente (non fornito)
  • Page 53 FORCE W 4.1 Dimensioni e attacchi fig. 62 - Vista frontale fig. 63 - Vista laterale fig. 64 - Vista dall’alto fig. 65 - Vista dal basso mod. FORCE W 60 e FORCE W 80 fig. 66 - Vista dal basso mod. FORCE W 99 e FORCE W 120 fig.
  • Page 54 FORCE W 4.2 Vista generale fig. 68 - Vista generale mod. FORCE W 60 e FORCE W 80 fig. 69 - Vista generale mod. FORCE W 99 e FORCE W 120 fig. 70 - Vista generale mod. FORCE W 150 cod.
  • Page 55 FORCE W 4.3 Circuito idraulico fig. 71 - Circuito idraulico cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 56 FORCE W 4.4 Tabella dati tecnici Nella colonna a destra viene indicata l’abbreviazione utilizzata nella targhetta dati tecnici. Modello FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 CODICI IDENTIFICATIVI DEI PRODOTTI 0MDLAAWA 0MDLCAWA 0MDLDAWA 0MDLEAWA 0MDLFAWA...
  • Page 57 FORCE W 4.5 Tabelle ErP cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 58 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 59 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 60 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 61 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 62 FORCE W 4.6 Diagrammi Perdita di carico fig. 72 - Diagramma perdita di carico modelli FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 73 - Diagramma perdita di carico modelli FORCE W 150 Portata - m cod.
  • Page 63 FORCE W 4.7 Schemi elettrici ATTENZIONE: Prima di collegare il termostato ambiente o il cronocomando remoto, togliere il ponticello sulla morsettiera. fig. 74 - Schema elettrico modelli FORCE W 60 e FORCE W 80 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 64 FORCE W fig. 75 - Schema elettrico modelli FORCE W 99, FORCE W 120 e FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 65 C e r t i f i c a t o d i G a ra n z i a La presente garanzia convenzionale è valida per gli apparecchi...
  • Page 66 FORCE W • Le rogamos leer atentamente las advertencias conte- bios originales. En caso contrario, se puede nidas en este manual de instrucciones, ya que pro- comprometer la seguridad del aparato. porcionan información importante sobre • Para garantizar el buen funcionamiento del aparato instalación, el uso y el mantenimiento.
  • Page 67 FORCE W 1 Instrucciones de uso ......................68 1.1 Presentación ............................68 1.2 Panel de mando ........................... 68 1.3 Encendido y apagado........................... 72 1.4 Regulaciones............................73 2 Instalación del aparato ......................83 2.1 Disposiciones generales ........................83 2.2 Lugar de instalación ..........................83 2.3 Conexiones de agua ..........................
  • Page 68 1.1 Presentación Estimado cliente: Gracias por elegir FORCE W, una caldera mural FERROLI con diseño avanzado, tecnología de vanguardia, elevada fiabilidad y calidad constructiva. Le rogamos leer atentamente el presente manual, ya que proporciona información im- portante sobre la instalación, el uso y el mantenimiento.
  • Page 69 FORCE W Teclas directas Las teclas directas ( 8, 9 y 10 - fig. 1) tienen siempre la misma función. Tecla de navegación en menús Las teclas de navegación en menús ( 5, 6, 7, 11, 12 y 13 - fig. 1) permiten recorrer los diversos menús implementados en el panel de control.
  • Page 70 FORCE W MANTENIMIENTO Vea fig. 59 Modo Test Vea fig. 56 Modo Test Selección del tipo de gas Modo Test Cascada Vea “Información Asistencia” on page 80 Información Asistencia Vea “Fecha intervención Asistencia” on page 80 Fecha intervención Asistencia AJUSTES Vea fig.
  • Page 71 FORCE W Exclusión del acumulador (modo Economy) El funcionamiento del acumulador (calentamiento del agua y mantenimiento en temperatura) puede ser desactivado por el usuario. En tal caso, no hay suministro de agua caliente sanitaria. Para desactivar el acumulador y establecer el modo ECO, pulse la tecla eco/comfort ( 10 - fig.
  • Page 72 FORCE W 1.3 Encendido y apagado Encendido de la caldera Pulse la tecla de encendido/apagado (14 - fig. 1). Display v.0X Unidad Modulo 1 v.0X fig. 7 - Encendido de la caldera Seleccione el idioma con la tecla contextual 1 y confírmelo con la tecla OK. Pulse la tecla contextual 3 si desea interrumpir el modo FH.
  • Page 73 FORCE W Abra la pantalla ilustrada en la fig. 9 con la ruta "MENÚ DE USUARIO “Ajustes” “Ajuste del horario”. Pulse las teclas de navegación 5 y 7 para seleccionar el valor y modifíquelo con las teclas contextuales 1 y 2. Confirme con la tecla OK.
  • Page 74 FORCE W Para desactivar el modo Verano, pulse otra vez la tecla ( 9 - fig. 1) durante 1 segundo. 23°C 32°C Jueves Jan. 2014 11:33:03 fig. 11 - Verano Regulación de la temperatura de calefacción Abra el menú “Temp. Regulación” para modificar la la temperatura entre 30 °C y 80 °C. Confirme con la tecla OK. Temp regulación para confirmar fig.
  • Page 75 FORCE W Regulación Reducción de la temperatura del ACS (con acumulador opcional instalado) Abra el menú “Temp. Regulación” para modificar la la temperatura entre 10 °C y 65 °C. Confirme con la tecla OK. Temp regulación para confirmar fig. 14 La caldera se entrega sin programa horario activado.
  • Page 76 FORCE W Programación del horario La programación del horario se hace del mismo modo para la calefacción y para el agua sanitaria; los dos programas son independientes. Para programar la calefacción, abra el menú "Programa horario" siguiendo la ruta "MENÚ DE USUARIO “CALE- FACCIÓN”...
  • Page 77 FORCE W Pulse la tecla de navegación 7 para situarse en el horario de terminación de la primera franja horaria (fig. 19) y ajuste el valor deseado con las teclas contextuales 1 y 2. Programa horario 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Page 78 FORCE W Programa horario 06:00 - 16:00 16:00 - 21:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copia de dia siguiente Guarda & Escape para confirmar fig. 22 Programa horario 06:00 - 16:00 16:00 - 21:00 21:00 - 06:00 --:-- - --:-- --:-- - --:--...
  • Page 79 FORCE W Programa antilegionela (con acumulador opcional instalado) Para habilitar la Función Antilegionela es necesario configurar el parámetro P23 del “MENÚ TÉCNICO en ON. Para programar la función es necesario acceder al menú “Legionela” siguiendo la ruta “MENÚ DE USUARIO” “AGUA CALIENTE SANITARIA”...
  • Page 80 FORCE W Función Vacaciones Abra el menú "FUNCIÓN VACACIONES" siguiendo la ruta "MENÚ DE USUARIO “FUNCIÓN VACACIONES” para programar: • Fecha de inicio de las vacaciones • Fecha de terminación de las vacaciones En la pantalla pueden aparecer dos tipos de iconos: •...
  • Page 81 FORCE W Ajuste el desplazamiento paralelo de las curvas de 20 a 60 °C (fig. 30) mediante el parámetro “Offset1” y confirme con la tecla OK. Offset 1 para confirmar fig. 28 - Desplazamiento paralelo de las curvas Si la temperatura ambiente es inferior al valor deseado, se aconseja seleccionar una curva de orden superior, y vice- versa.
  • Page 82 FORCE W Regulaciones con el cronomando remoto Cuando la caldera tiene conectado el cronomando remoto (opcional), las regulaciones anteriormente descri- tas se realizan como se indica en la tabla 1. Tabla 1 Este ajuste se puede hacer tanto en el menú del cronomando remoto como en el panel de Regulación de la temperatura de cale- mandos de la caldera.
  • Page 83 FORCE W 2. Instalación del aparato 2.1 Disposiciones generales LA CALDERA TIENE QUE SER INSTALADA ÚNICAMENTE POR PERSONAL ESPECIALIZADO Y DEBIDAMENTE CUALIFICADO, RESPETANDO TODAS LAS INSTRUCCIONES DEL PRESENTE MANUAL TÉCNICO, LAS LEYES NACIONALES Y LOCALES ASÍ COMO LAS REGLAS DE LA TÉCNICA. 2.2 Lugar de instalación El generador se debe instalar en un local específico, con aberturas de ventilación hacia el exterior, según lo dispuesto por las normas vigentes.
  • Page 84 FORCE W Circulador de alta eficiencia (opcional) Los ajustes de fábrica son idóneos para todas las instalaciones. No obstante, mediante el selector de velocidad (fig. 32) es posible modificar la estrategia de funcionamiento de acuerdo con las necesidades particulares. 1 2 3 fig.
  • Page 85 FORCE W Características del agua de la instalación Antes de instalar el generador FORCE W, es necesario limpiar a fondo el sistema, ya sea nuevo o existente, para eli- minar residuos de mecanizado, disolventes, lodos y contaminantes en general que puedan comprometer la eficacia de los tratamientos de protección.
  • Page 86 FORCE W Tabla 2- Acondicionadores químicos declarados idóneos y disponibles en nuestra red de centros de asistencia técnica autorizada. Productos alternativos tipo Senti- Descripción Inhibidor de corrosión a base de molibdeno X100 LIFE PLUS/B - MOLY - MOLY K Reducción del ruido y antincrustante de mantenimiento X200 LIFE DUE Antialgas biocida...
  • Page 87 FORCE W Kits opcionales A petición, se suministran los siguientes kits: cód. 042070X0 - KIT CIRCULADOR DE ALTA EFICIENCIA - 7 m (A - fig. 36) cód. 042071X0 - KIT CIRCULADOR DE ALTA EFICIENCIA - 10 m (A - fig. 36) cód.
  • Page 88 FORCE W Ejemplos de circuitos hidráulicos En los ejemplos siguientes se indica la necesidad de controlar/modificar algunos parámetros. Para ello se debe acceder al menú Técnico. Desde la pantalla principal (Inicio), pulse la tecla Menú principal ( 12 - fig. 1). Abra el menú...
  • Page 89 FORCE W Dos circuitos de calefacción directos - Esquema general fig. 41 - Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente. A continuación, configure la centralita como se describe en el apartado correspondiente. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44...
  • Page 90 FORCE W Leyenda (fig. 41 - fig. 42) Termostato de ambiente 1ª zona (directa) 1ª zona (directa) Termostato de ambiente 2ª zona (directa) 2ª zona (directa) Sonda exterior Circulador 1ª zona (directa) Retorno Circulador 2ª zona (directa) Dispositivos de seguridad ISPESL (cuando sean necesarios - no suministrados) Para el control de la temperatura adaptable es necesario adquirir la sonda exterior accesoria cód.
  • Page 91 FORCE W Un circuito de calefacción directo y un circuito de AS con circulador - Esquema general fig. 44 - Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente. A continuación, configure la centralita como se describe en el apartado correspondiente. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44...
  • Page 92 FORCE W Leyenda (fig. 44 - fig. 45) Termostato de ambiente 1ª zona (directa) 1ª zona (directa) Circulador del acumulador Circuito del acumulador Sonda exterior Sonda del acumulador Retorno Circulador antilegionela Circulador 1ª zona (directa) Dispositivos de seguridad ISPESL (cuando sean necesarios - no suministrados) Para el control de la temperatura adaptable es necesario adquirir la sonda exterior accesoria cód.
  • Page 93 FORCE W Un circuito de calefacción directo y un circuito de ACS con válvula desviadora (de 3 hilos) - Esquema general Utilice válvulas desviadoras de tres hilos: - FASE DE APERTURA 230 V - FASE DE CIERRE 230 V - NEUTRO con tiempos de conmutación (de todo cerrado a todo abierto) no superiores a 90 s.
  • Page 94 FORCE W Leyenda (fig. 46 - fig. 47) Circulador de calefacción 1ª zona (directa) Termostato de ambiente 1ª zona (directa) Circuito del acumulador Sonda exterior Sonda del acumulador Retorno Válvula de 3 vías (3 hilos) A = FASE DE APERTURA B = NEUTRO C = FASE DE CIERRE Dispositivos de seguridad ISPESL (cuando sean necesarios - no suministrados)
  • Page 95 FORCE W Dos circuitos de calefacción mezclados, un circuito de calefacción directo y un circuito de AS con circulador - Esquema general La tarjeta de control de zonas FZ4B puede gestionar distintos tipos de instalación. El esquema presente es solo un ejemplo.
  • Page 96 FORCE W - Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente. A continuación, configure la centralita como se describe en el apartado correspondiente. fig. 50 Leyenda Termostato de ambiente 1ª zona (mezclada) Termostato de seguridad 1ª...
  • Page 97 FORCE W - Parámetros Cada aparato necesita una parametrización diferente. Proceda como se describe a continuación. Menú "Parámetros - Configuración” Controle/ajuste el parámetro b02 del menú "Parámetros - Configuración” a 9. Controle/ajuste el parámetro b08 del menú "Parámetros - Configuración” a 1. Controle/ajuste los parámetros b04, b05 y b06 del menú...
  • Page 98 FORCE W 2.4 Conexión del gas Antes de efectuar la conexión, controlar que el aparato esté preparado para fun- cionar con el tipo de combustible disponible y limpiar esmeradamente todos los tu- bos del gas para eliminar los residuos, que podrían perjudicar el funcionamiento de la caldera.
  • Page 99 FORCE W Sonda exterior (opcional) Conectar la sonda a los bornes correspondientes. El cable eléctrico utilizado para conectar la sonda exterior a la cal- dera no debe medir más de 50 m. Se puede usar un cable común de dos conductores. La sonda exterior tiene que instalarse preferiblemente en una pared orientada al norte o noroeste, o en la pared correspondiente a la parte principal del salón.
  • Page 100 FORCE W 2.6 Conductos de humos LOS LOCALES DONDE SE INSTALEN LAS CALDERAS DEBEN CUMPLIR LOS REQUISITOS DE VENTILACIÓN FUNDAMENTALES. EN CASO CON- TRARIO, EXISTE PELIGRO DE ASFIXIA O INTOXICACIÓN. LEA LAS INSTRUCCIONES DE INSTALACIÓN Y MANTENIMIENTO ANTES DE INSTALAR EL APARATO. RESPETE TAMBIÉN LAS INSTRUCCIONES DE DISEÑO.
  • Page 101 FORCE W Tabla 4Tabla de accesorios MODELOS FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 Presión de impulsión máxima permitida (Pa) TUBO 1 m M/H 11,9 24,5 TUBO 0,5 m M/H 12,3 CODO 90° Ø80 CODO 45°...
  • Page 102 FORCE W 2.7 Conexión de la descarga de condensado ADVERTENCIAS La caldera está dotada de un sifón para la descarga del condensado. Siga las instrucciones de montaje. 1. Fije el sifón. 2. Antes de conectar el tubo flexible al desagüe, llene el sifón con agua. 3.
  • Page 103 Todas las operaciones de regulación, transformación, puesta en servicio y mantenimiento que se describen a continuación deben ser efectuadas exclusivamente por un técnico autorizado, por ejemplo del Servicio de Asistencia local. FERROLI declina toda responsabilidad por daños materiales o personales derivados de la manipulación del aparato por personas que no estén debidamente autorizadas.
  • Page 104 FORCE W fig. 57- Modelos FORCE W 60 y FORCE W 80 fig. 58- Modelos FORCE W 99, FORCE W 120 y FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 105 FORCE W Activación del modo TEST Abra la pantalla ilustrada en la fig. 59 con la ruta "MENÚ USUARIO Mantenimiento Modo Test Modo Test”. La caldera se enciende y alcanza gradualmente la potencia máxima de calefacción (Range Rated) ajustada como se describe en el apartado siguiente.
  • Page 106 FORCE W Diagrama de regulación de la capacidad térmica A = kW - B = parámetro tarjeta electrónica fig. 60 MENÚ TÉCNICO EL ACCESO AL MENÚ SERVICE Y LA MODIFICACIÓN DE LOS PARÁMETROS ESTÁN RESERVADOS AL PER- SONAL AUTORIZADO. El acceso al Menú Técnico exige la introducción del código 4 1 8. Es válido por 15 minutos. Menú...
  • Page 107 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Parámetro Descripción Campo OFF = desactivado, Sensor de humos ON = activado No implementado Temperatura máxima humos 0-125 °C Selección tipo ventilador Tiempo funcionamiento antiblo- 0-20 segundos queo bomba Notas 1.
  • Page 108 FORCE W FORCE W FORCE W FORCE FORCE W FORCE Parámetro Descripción Campo W 99 W 150 Con B02 = 7 - No implementado Con B02 = 8 - Valor de referencia primario 70° - 85° 80° 80° 80° 80° 80°...
  • Page 109 FORCE W Parámetro Descripción Campo FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 Función carga de la ins- OFF = deshabilitado, ON = habilitado P.10 talación Selección válvula de 3 2/3 = 2 o 3 hilos P.11 vías 2 = 2 hilos...
  • Page 110 FORCE W • Controlar que no haya pérdidas de agua en la instalación, en los circuitos de agua sanitaria, en las conexiones ni en la caldera. • Controlar que la conexión a la instalación eléctrica y la puesta a tierra sean adecuadas. •...
  • Page 111 FORCE W • Control de la presión del agua de la instalación, que debe ser estable y conforme a la presión de funcionamiento establecida para la central. Si se utiliza un sistema de carga automática para restablecer las condiciones de funcionamiento, el agua introducida debe someterse antes a un tratamiento adecuado (ver ).
  • Page 112 FORCE W Mantenimiento extraordinario y sustitución de componentes Sustitución del electrodo Limpieza del intercambiador cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 113 FORCE W 3.4 Solución de problemas Diagnóstico La caldera está dotada de un avanzado sistema de autodiagnóstico. Si se presenta una anomalía en la caldera, la pan- talla se enciende indicando el código de anomalía y, si se trata de una conexión en cascada, el número de módulo. •...
  • Page 114 FORCE W Código Anomalía Causa posible Solución anomalía Indicación de sobretem- peratura del sensor de calefacción 1 (ida) circulación del agua de la instalación insuficiente controlar la circulación del agua (Solo se visualiza en el menú History) Indicación de sobretem- peratura del sensor de retorno circulación del agua de la instalación insuficiente...
  • Page 115 FORCE W Código Anomalía Causa posible Solución anomalía Protección por diferen- Controlar la circulación de agua caldera/instala- Circulación insuficiente en caldera cia de temperatura > ción 21° entre sensor de ida Posición del sensor de ida incorrecta Controlar el estado del sensor y sensor de seguridad Sensor averiado Anomalía del sensor de...
  • Page 116 FORCE W 4. Características y datos técnicos Leyenda de las figuras cap. 4 Entrada de gas - Ø 1” Ida a calefacción - Ø 1” 1/2 Retorno de calefacción - Ø 1” 1/2 Válvula de seguridad Ventilador Circulador de calefacción (no suministrado) Sensor temperatura calefacción Purgador de aire automático Válvula del gas...
  • Page 117 FORCE W 4.1 Medidas y conexiones fig. 62- Vista frontal fig. 63- Vista lateral fig. 64- Vista superior fig. 65- Vista inferior mods. FORCE W 60 y FORCE W 80 fig. 66- Vista inferior mods. FORCE W 99 y FORCE W 120 fig.
  • Page 118 FORCE W 4.2 Vista general fig. 68- Vista general mods. FORCE W 60 y FORCE W 80 fig. 69- Vista general mods. FORCE W 99 y FORCE W 120 fig. 70- Vista general mod. FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 119 FORCE W 4.3 Circuito de agua fig. 71- Circuito de agua cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 120 FORCE W 4.4 Tabla de datos técnicos En la columna derecha se indica la abreviatura utilizada en la placa de datos técnicos. FORCE W FORCE W FORCE W FORCE W FORCE W Modelo CÓDIGOS DE IDENTIFICACIÓN DE LOS PRODUCTOS 0MDLAAWA 0MDLCAWA 0MDLDAWA 0MDLEAWA 0MDLFAWA PAÍSES DE DESTINO IT ES RO RU PL BG DE GR HR LV UA...
  • Page 121 FORCE W 4.5 Tablas ErP cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 122 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 123 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 124 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 125 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 126 FORCE W 4.6 Diagrasmas Pérdida de carga fig. 72- Diagrama de pérdida de carga modelos FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 73- Diagrama de pérdida de carga modelos FORCE W 150 Caudal - m cod.
  • Page 127 FORCE W 4.7 Esquemas eléctricos ATENCIÓN: Antes de conectar el termostato de ambiente o el cronomando remoto, quite el puente de la regleta de conexiones. fig. 74- Esquema eléctrico modelos FORCE W 60 y FORCE W 80 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 128 FORCE W fig. 75- Esquema eléctrico modelos FORCE W 99, FORCE W 120 y FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 129 Esta garantía comercial es válida siempre que se realicen las operaciones normales de mantenimiento descritas en las Muchas gracias por elegir SILENT D eco 30 COND K 100 UNIT, una caldera de pie FERROLI de diseño avanzado, tecnología de vanguardia, elevada fiabilidad y calidad instrucciones técnicas suministradas con los equipos.
  • Page 130 FORCE W • Citiţi cu atenţie avertizările din acest manual de instrucţiu- se de schimb originale. Nerespectarea celor menţionate ni întrucât oferă indicaţii importante referitoare la sigu- mai sus poate compromite siguranţa aparatului. ranţa de instalare, utilizare şi întreţinere. • Pentru a garanta buna funcţionare a aparatului este indi- •...
  • Page 131 FORCE W 1 Instrucţiuni de utilizare......................132 1.1 Prezentare ............................132 1.2 Panoul de comandă ........................... 132 1.3 Pornirea şi oprirea ..........................136 1.4 Reglările ............................. 137 2 Instalarea ..........................147 2.1 Dispoziţii generale ..........................147 2.2 Locul de instalare ..........................147 2.3 Racordurile hidraulice.........................
  • Page 132 1.1 Prezentare Stimate Client, Vă mulţumim că aţi ales FORCE W, o centrală murală FERROLI de concepţie avansată, tehnologie de avangardă, nivel ridicat de fiabilitate şi calitate constructivă. Vă rugăm să citiţi cu atenţie acest manual întrucât oferă indicaţii importante referitoare la siguranţa de instalare, utilizare şi întreţinere.
  • Page 133 FORCE W Tastele directe Tastele directe (det. 8, 9, 10 - fig. 1) au întotdeauna aceeaşi funcţie. Tastele navigaţie/meniu Tastele navigaţie/meniu (det. 5, 6, 7, 11, 12, 13 - fig. 1) ajută la navigarea printre diferitele meniuri setate pe panoul de control.
  • Page 134 FORCE W ÎNTREŢINEREA Vezi fig. 59 Modul Test Vezi fig. 56 Modul Test Selectarea tipului de gaz Vezi Modul Test Cascadă Vezi “Informaţii Service” on page 144 Informaţii Service Vezi “Dată intervenţie service” on page 144 Dată intervenţie service SETĂRI Vezi fig.
  • Page 135 FORCE W Excludere boiler (economy) Încălzirea/menţinerea temperaturii boilerului poate fi exclusă de către utilizator. În caz de excludere, nu se va produce apă caldă menajeră. Boilerul poate fi dezactivat de către utilizator (modul ECO) apăsând pe tasta eco/comfort (det. 10 - fig.
  • Page 136 FORCE W 1.3 Pornirea şi oprirea Pornirea centralei Apăsaţi pe tasta de aprindere/stingere (det. 14 - fig. 1). Display v.0X Burner Controller 1 v.0X fig. 7- Pornirea centralei Apăsând pe tasta contextuală 1 puteţi alege limba dorită şi o puteţi confirma cu ajutorul tastei „OK”. Apăsând pe tasta contextuală...
  • Page 137 FORCE W Duceţi-vă la ecranul prezentat în fig. 9 navigând în meniu, urmând calea „MENIU USER „Setări” „Set time”. Apă- saţi tastele de navigare 5 şi 7 pentru a selecta valoarea şi a o modifica prin intermediul tastelor contextuale 1 şi 2. Con- firmaţi cu tasta OK.
  • Page 138 FORCE W Pentru a dezactiva modul Vară, apăsaţi din nou tasta (det. 9 - fig. 1) timp de 1 secundă. 23°C 32°C Thursday 9 Jan. 2014 11:33:03 fig. 11- Vară Reglarea temperaturii în circuitul de încălzire Accesaţi meniul „Temp. de reglare” pentru a modifica temperatura de la un minim de 20°C la un maxim de 80°. Con- firmaţi cu tasta OK.
  • Page 139 FORCE W Reglarea reducerii temperaturii apei calde menajere (cu boiler opţional instalat) Accesaţi meniul „Temp. de reglare” pentru a modifica temperatura de la un minim de 10°C la un maxim de 65°C. Con- firmaţi cu tasta OK. CH setpoint to confirm fig.
  • Page 140 FORCE W Programarea orarului Programarea orarului se face în acelaşi mod atât pentru încălzire, cât şi pentru apa caldă menajeră; cele două programe sunt independente. Pentru programarea Încălzirii accesaţi meniul “Programarea orarului” urmând calea „MENIU USER „ÎNCĂLZIRE” „Scheduler set”. Pentru programarea Apei calde menajere accesaţi meniul “Programarea orarului” urmând calea „MENIU USER „APĂ...
  • Page 141 FORCE W Apăsaţi tasta de navigaţie 7 pentru a vă poziţiona pe ora de terminare a primului interval orar (fig. 19) şi setaţi-o la va- loarea dorită cu ajutorul tastelor contextuale 1 şi 2. Scheduler Set 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Page 142 FORCE W Scheduler Set 06:00 - 16:00 16:00 - 21:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copy to the Next Day Save & Exit to confirm fig. 22 Scheduler Set 06:00 - 16:00 16:00 - 21:00 21:00 - 06:00 --:-- - --:-- --:-- - --:--...
  • Page 143 FORCE W Programarea Legionella (cu boiler opţional instalat) Pentru a activa Funcţi Antilegionella este necesar să setaţi parametrul P23, din „MENIUL TECHNICIAN”, pe ON. Pentru a programa funcţia este necesar să accesaţi meniul „Legionella” urmând calea „MENIU USER” „DHW” „Legionella”. În acest meniu se pot seta următoarele opţiuni: •...
  • Page 144 FORCE W Funcţia Vacanţă Accesaţi meniul „FUNCŢIA VACANŢĂ” urmând calea „MENIU USER „FUNCŢIA VACANŢĂ” pentru a putea seta: • Data de începere a vacanţei. • Data de terminare a vacanţei. Pe afişaj se pot activa două tipuri de pictograme: • - Funcţia Vacanţă...
  • Page 145 FORCE W Reglaţi deplasarea paralelă a curbelor de la 20 la 60°C (fig. 30), cu ajutorul parametrului „Offset1”, şi confirmaţi cu tasta OK. OTC Offset 1 to confirm fig. 28- Deplasarea paralelă a curbelor Dacă temperatura ambiantă e mai mică faţă de valoarea dorită, se recomandă să selectaţi o curbă de ordin superior şi invers.
  • Page 146 FORCE W Reglările de la cronocomanda la distanţă Dacă la centrală este conectată Cronocomanda la distanţă (opţional), reglările de mai sus trebuie efectuate conform indicaţiilor din tabel 1. Tabel 1 Reglarea poate fi efectuată fie din meniul Cronocomenzii la distanţă, fie de la panoul de Reglarea temperaturii în circuitul de comandă...
  • Page 147 FORCE W 2. Instalarea 2.1 Dispoziţii generale INSTALAREA CENTRALEI TREBUIE EFECTUATĂ NUMAI DE PERSONAL SPECIALIZAT ŞI CU CALIFICARE RE- CUNOSCUTĂ, RESPECTÂNDU-SE TOATE INSTRUCŢIUNILE MENŢIONATE ÎN PREZENTUL MANUAL TEHNIC, DISPOZIŢIILE LEGALE ÎN VIGOARE, CERINŢELE NORMELOR NAŢIONALE ŞI LOCALE ŞI CONFORM REGULI- LOR DE BUNĂ...
  • Page 148 FORCE W Pompă de circulaţie cu eficienţă ridicată (opţional) Setarea din fabricaţie este adecvată pentru toate tipurile de instalare; cu toate acestea, este posibil să se seteze, cu ajutorul selectorului de viteză (vezi fig. 32), o strategie de funcţionare diferită, în funcţie de caracteristicile instalaţiei. 1 2 3 fig.
  • Page 149 FORCE W Caracteristicile apei din instalaţie Înainte de a începe instalarea generatorului FORCE W, instalaţia, nouă sau existentă, trebuie să fie curăţată corespun- zător, pentru a elimina reziduurile de la instalare, solvenţii, nămolurile şi contaminanţii în general care ar putea reduce eficienţa tratamentelor cu substanţe chimice de protecţie.
  • Page 150 FORCE W Tabel 2- Produse chimice de tratare declarate adecvate şi disponibile în reţeaua noastră de Centre de Asistenţă Tehnică Autorizată Descriere Produse alternative de tip Sentinel Inhibitor de coroziune pe bază de molibden X100 LIFE PLUS/B - MOLY - MOLY K Reducerea zgomotului/inhibitor de depuneri de întreţinere X200 LIFE DUE...
  • Page 151 FORCE W Kituri opţionale La cerere sunt disponibile următoarele kituri: cod 042070X0 - KIT POMPĂ DE CIRCULAŢIE cu EFICIENŢĂ RIDICATĂ - 7 m. (A - fig. 36) cod 042071X0 - KIT POMPĂ DE CIRCULAŢIE cu EFICIENŢĂ RIDICATĂ - 10 m. (A - fig. 36) cod 042072X0 - KIT HIDRAULIC În Kit 042072X0 se află: VALVĂ...
  • Page 152 FORCE W Exemple circuite hidraulice În exemplele descrise mai jos poate fi necesar să se verifice/modifice unii parametri. Pentru a face acest lucru este necesar să se acceseze meniul Technician. De pe ecranul principal (Home), apăsaţi tasta Meniu principal (det. 12 - fig. 1). Accesaţi meniul „Technician”...
  • Page 153 FORCE W Două circuite de încălzire directe - Schemă de principiu fig. 41 - Conexiuni electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică. După aceea, treceţi la configurarea unităţii de comandă, după cum se arată în paragraful respectiv. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44...
  • Page 154 FORCE W Legendă (fig. 41 - fig. 42) Termostat de cameră zona 1 (directă) Zona 1 (directă) Termostat de cameră zona a 2-a (directă) Zona a 2-a (directă) Sondă externă Pompă de circulaţie zona 1 (directă) Retur Pompă de circulaţie zona a 2-a (directă) Dispozitive de siguranţă...
  • Page 155 FORCE W Un circuit de încălzire direct şi un circuit de apă menajeră cu pompă de circulaţie - Schemă de principiu fig. 44 - Conexiuni electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică. După...
  • Page 156 FORCE W Legendă (fig. 44 - fig. 45) Termostat de cameră zona 1 (directă) Zona 1 (directă) Pompă de circulaţie boiler Circuit boiler Sondă externă Sondă boiler Retur Pompă de circulaţie anti-legionella Pompă de circulaţie zona 1 (directă) Dispozitive de siguranţă ISPESL (Când sunt necesare - nu sunt furnizate) Pentru a controla temperatura variabilă...
  • Page 157 FORCE W Un circuit de încălzire direct şi un circuit de apă menajeră cu valvă deviatoare (cu 3 fire) - Schemă de principiu Utilizaţi valve deviatoare cu 3 fire: - FAZA DE DESCHIDERE 230 V - FAZA DE ÎNCHIDERE 230 V - NEUTRU cu timpi de comutare (de la complet închis la complet deschis) nu mai mari de 90 secunde.
  • Page 158 FORCE W Legendă (fig. 46 - fig. 47) Pompă de circulaţie încălzire Zona 1 (directă) Termostat de cameră zona 1 (directă) Circuit boiler Sondă externă Sondă boiler Retur Valvă cu 3 căi (cu trei fire) A = FAZA DE DESCHIDERE B = NEUTRU C = FAZA DE ÎNCHIDERE Dispozitive de siguranţă...
  • Page 159 FORCE W Două circuite de încălzire mixte, un circuit de încălzire direct şi un circuit de apă menajeră cu pompă de circulaţie - Schemă de principiu Cartela pentru controlul pe zone FZ4B poate controla diferite tipuri de instalaţii. Aici este prezentat un exemplu. Utilizaţi valve deviatoare cu 3 fire: - FAZA DE DESCHIDERE 230 V - FAZA DE ÎNCHIDERE 230 V...
  • Page 160 FORCE W - Conexiuni electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică. După aceea, treceţi la configurarea unităţii de comandă, după cum se arată în paragraful respectiv. fig. 50 Legendă...
  • Page 161 FORCE W - Parametri Fiecare instalaţie necesită o configurare diferită a parametrilor. Urmaţi procedura de acces indicată mai jos. „Configuration - Parameters Menu” Verificaţi/Modificaţi parametrul b02 din „Configuration - Parameters Menu” la 9. Verificaţi/Modificaţi parametrul b08 din „Configuration - Parameters Menu” la 1. Verificaţi/Modificaţi parametrii b04, b05 şi b06 din „Configuration - Parameters Menu”...
  • Page 162 FORCE W 2.4 Racordarea la gaz Înainte de efectuarea racordării, verificaţi ca aparatul să fie proiectat pentru funcţionarea cu tipul de combustibil disponibil şi efectuaţi o curăţare corectă a tu- turor ţevilor de gaz ale instalaţiei, pentru a îndepărta eventualele reziduuri care ar putea compromite buna funcţionare a centralei.
  • Page 163 FORCE W Sondă externă (opţional) Conectaţi sonda la bornele corespunzătoare. Lungimea maximă permisă a cablului electric de conectare centrală – son- dă externă este de 50 m. Poate fi utilizat un cablu obişnuit cu 2 conductoare. Sonda externă trebuie instalată de preferat pe peretele dinspre nord, nord-vest, sau pe cel pe care se află...
  • Page 164 FORCE W 2.6 Conductele pentru gaze arse CENTRALELE TREBUIE SĂ FIE INSTALATE ÎN ÎNCĂPERI CARE CORE- SPUND CERINŢELOR DE VENTILAŢIE FUNDAMENTALE. ÎN CAZ CONTRAR EXISTĂ PERICOLUL DE ASFIXIE SAU DE INTOXICARE. CITIŢI INSTRUCŢIUNILE DE INSTALARE ŞI DE ÎNTREŢINERE ÎNAINTE DE A INSTALA APARATUL.
  • Page 165 FORCE W Tabel 4Tabel accesorii MODELE FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 Înălţimea de pompare maximă permisă (Pa) TUB 1 M tată/mamă 11,9 16,0 24,5 TUB 0,5 M tată/mamă 12,3 COT 90° Ø80 COT 45°...
  • Page 166 FORCE W 2.7 Racordarea evacuării condensului AVERTIZĂRI Centrala este dotată cu un sifon pentru evacuarea condensului. Urmaţi instrucţiunile pentru a efectua montarea. 1. Fixaţi sifonul. 2. Înainte de a racorda tubul flexibil la instalaţia de evacuare, umpleţi sifonul cu apă. 3.
  • Page 167 Personal Calificat şi cu o calificare atestată (în posesia cerinţelor tehnice profesionale prevăzute de normele în vigoare), ca, de ex., personalul de la Serviciul Tehnic de Asistenţă Clienţi din zonă. FERROLI îşi declină orice responsabilitate pentru pagubele produse bunurilor şi/sau persoanelor ca urmare a intervenţiilor efectuate asupra aparatului de persoane necalificate şi neautorizate.
  • Page 168 FORCE W fig. 57- Modelele FORCE W 60 şi FORCE W 80 fig. 58- Modelele FORCE W 99, FORCE W 120 şi FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 169 FORCE W Activarea modului TEST Duceţi-vă la ecranul prezentat în fig. 59 navigând în meniu, urmând calea „MENIU USER Întreţinerea Modul Test Installer Test Mode”. Centrala se aprinde, atingând puterea maximă de încălzire (Range Rated), reglată conform paragrafului următor, în mod treptat.
  • Page 170 FORCE W Diagramă de reglare a puterii termice A = kW - B = Parametru cartelă electronică fig. 60 MENIUL TECHNICIAN ACCESUL LA MENIUL SERVICE ŞI MODIFICAREA PARAMETRILOR POT FI EFECTUATE NUMAI DE PERSO- NAL CALIFICAT. Accesul la Meniul Technician este posibil numai după ce aţi introdus codul 4 1 8. Şi este valabil timp de 15 minute. Meniul Parametri - Configurare Sunt disponibili 16 parametri indicaţi cu litera „b”...
  • Page 171 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Parametru Descriere Interval Post-ventilaţie în încăperea cu 1-15 minute centrala OFF=Dezactivat, Senzor gaze arse ON=Activat Nu este implementat Temperatură maximă gaze arse 0-125 °C Selectarea tipului de ventilator Durată...
  • Page 172 FORCE W FORCE W FORCE W FORCE FORCE W FORCE Parametru Descriere Interval W 99 W 150 Cu B02 = 7 - Neimplementat Cu B02 = 8 - Setpoint primar 70° ÷ 85° 80° 80° 80° 80° 80° Cu B02 = 9 - Setpoint primar 70°...
  • Page 173 FORCE W Parametru Descriere Interval FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 2/3 = 2 sau 3 fire Selectare vană cu 3 căi P.11 2 = 2 fire 0-10 V c.c. Tensiune încălzire OFF (Control 0,1-10 V c.c.
  • Page 174 FORCE W • Verificaţi ca valoarea presiunii gazului pentru circuitul de încălzire să fie cea necesară • Verificaţi să nu existe lichide sau materiale inflamabile în imediata apropiere a centralei. DACĂ INSTRUCŢIUNILE DE MAI SUS NU SUNT RESPECTATE, POT EXISTA RISCUL DE SUFOCARE SAU DE OTRĂVIRE DIN CAUZA SCURGERILOR DE GAZ SAU DE FUM, PERICOLUL DE INCENDIU SAU DE EXPLOZIE.
  • Page 175 FORCE W • Verificarea presiunii corecte şi stabile a apei din instalaţie, asigurând conformitatea cu presiunea de lucru prevăzută pentru centrală. Utilizarea unor sisteme de umplere automată pentru restabilirea condiţiilor de funcţionare trebuie să prevadă o tratare adecvată a apei introduse în instalaţie (det.
  • Page 176 FORCE W Întreţinerea extraordinară şi înlocuirea componentelor. Înlocuirea electrodului Curăţarea schimbătorului de căldură 3.4 Rezolvarea problemelor cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 177 FORCE W Diagnosticarea Centrala este dotată cu un sistem avansat de autodiagnosticare. În cazul apariţiei unei anomalii la centrală, afişajul se aprinde, indicând codul anomaliei şi, în cazul conectării în cascadă, numărul modulului. • Există anomalii care cauzează blocări permanente, care pot fi resetate apăsând pe tasta OK timp de o secundă sau cu ajutorul tastei RESET de pe cronocomanda la distanţă...
  • Page 178 FORCE W Anomalie Cauză posibilă Soluţie anomalie Senzor defect Anomalie senzor gaze arse Cablaj în scurtcircuit Verificaţi cablajul sau înlocuiţi senzorul Cablaj întrerupt Senzor defect Anomalie senzor de tur 2 Cablaj în scurtcircuit Verificaţi cablajul sau înlocuiţi senzorul Cablaj întrerupt Lipsa tensiunii de alimentare 230V Verificaţi cablajul conectorului cu 3 borne Anomalie ventilator...
  • Page 179 FORCE W 4. Caracteristici şi date tehnice Legendă figuri cap. 4 "Caracteristici şi date tehnice" Intrare gaz - Ř 1” Tur instalaţie - Ř 1” 1/2 Retur instalaţie - Ř 1” 1/2 Supapă de siguranţă Ventilator Pompă de circulaţie încălzire (nu este furnizată) Senzor temperatură...
  • Page 180 FORCE W 4.1 Dimensiuni şi racorduri fig. 62- Vedere frontală fig. 63- Vedere laterală fig. 64- Vedere de sus fig. 65- Vedere de jos, mod. FORCE W 60 şi FORCE W 80 fig. 66- Vedere de jos, mod. FORCE W 99 şi FORCE W 120 fig.
  • Page 181 FORCE W 4.2 Vedere generală fig. 68- Vedere generală mod. FORCE W 60 şi FORCE W 80 fig. 69- Vedere generală mod. FORCE W 99 şi FORCE W 120 fig. 70- Vedere generală mod. FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 182 FORCE W 4.3 Circuitul hidraulic fig. 71- Circuitul hidraulic cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 183 FORCE W 4.4 Tabel cu datele tehnice În coloana din dreapta este indicată abrevierea utilizată pe plăcuţa cu datele tehnice. FORCE W FORCE W FORCE W FORCE W FORCE W Model CODURILE DE IDENTIFICARE ALE PRODUSELOR 0MDLAAWA 0MDLCAWA 0MDLDAWA 0MDLEAWA 0MDLFAWA ŢĂRILE DE DESTINAŢIE IT ES RO RU PL BG DE GR HR LV UA...
  • Page 184 FORCE W 4.5 Tabele ErP cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 185 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 186 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 187 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 188 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 189 FORCE W 4.6 Diagrame Pierdere de sarcină fig. 72- Diagramă pierderi de sarcină modelele FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 73- Diagramă pierderi de sarcină modelele FORCE W 150 Debit - m cod.
  • Page 190 FORCE W 4.7 Scheme electrice ATENŢIE: Înainte de a racorda termostatul de cameră sau cronocomanda la distanţă, scoateţi puntea de pe pa- noul de borne. fig. 74- Schemă electrică modelele FORCE W 60 şi FORCE W 80 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 191 FORCE W fig. 75- Schemă electrică modelele FORCE W 99, FORCE W 120 şi FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 192 FORCE W • Read the warnings in this instruction booklet • Periodic maintenance performed by qualified carefully since they provide important information personnel is essential in order to ensure proper on safe installation, use and maintenance. operation of the unit. •...
  • Page 193 FORCE W 1 Operating instructions ......................194 1.1 Introduction............................194 1.2 Control panel ............................194 1.3 Lighting and shutdown ........................198 1.4 Adjustments............................199 2 Installation ..........................209 2.1 General Instructions ........................... 209 2.2 Place of installation ..........................209 2.3 Plumbing connections ........................209 2.4 Gas connection ..........................
  • Page 194 1.1 Introduction Dear Customer, Thank you for choosing FORCE W, a FERROLI wall-mounted boiler featuring advanced design, cutting-edge techno- logy, high reliability and quality construction. Please read this manual carefully, as it provides important information on safe installation, use and maintenance.
  • Page 195 FORCE W Direct buttons The direct buttons (details 8, 9, 10 - fig. 1) always have the same function. Menu/navigation buttons The menu/navigation buttons (details 5, 6, 7, 11, 12, 13 - fig. 1) are used to navigate among the various menus imple- mented in the control panel.
  • Page 196 FORCE W MAINTENANCE See fig. 59 Test mode See fig. 56 Test mode Gas Type Selection Cascade Test Mode See “Service Information” on page 206 Service Information See “Service Intervention Date” on page 206 Service Intervention Date SETTINGS See fig. 7 Language Unit of Measure See fig.
  • Page 197 FORCE W Exclude hot water tank (economy) Hot water tank temperature maintaining/heating can be excluded by the user. In case of exclusion, there will be no de- livery of domestic hot water. The hot water tank can be deactivated by the user (ECO mode) by pressing the eco/ comfort button (detail 10 - fig.
  • Page 198 FORCE W 1.3 Lighting and shutdown Boiler lighting Press the On/Off button (detail 14 - fig. 1). Display v.0X Burner Controller 1 v.0X fig. 7 - Boiler lighting Press the contextual button 1 to select the language, confirming it by pressing "OK". Press the contextual button 3 to stop FH mode.
  • Page 199 FORCE W Reach the screen shown in fig. 9, navigating in the menu and following the path "USER MENU “Settings” “Time Setting”. Press the navigation buttons 5 and 7 to select the value and modify it with the contextual buttons 1 and 2. Con- firm with the OK button.
  • Page 200 FORCE W To deactivate Summer mode, press the button (detail 9 - fig. 1) again for 1 second. 23°C 32°C Thursday 9 Jan. 2014 11:33:03 fig. 11 - Summer Heating temperature adjustment Access the menu “Adjustment Temp” to vary the temperature from a minimum of 20°C to a maximum of 80°C. Confirm with the OK button.
  • Page 201 FORCE W DHW temperature reduction adjustment (with optional hot water tank installed) Access the menu “Adjustment Temp” to vary the temperature from a minimum of 10°C to a maximum of 65°C. Confirm with the OK button. CH setpoint to confirm fig.
  • Page 202 FORCE W Time programming Programming the time is done in the same way both for heating and for DHW; the two programs are independent. To program Heating access the "Time Program" menu following the path "USER MENU “HEATING” “Time Pro- gram”.
  • Page 203 FORCE W Press the navigation button 7 to move to the end time of the first time band (fig. 19) and set it to the desired value using the contextual buttons 1 and 2. Scheduler Set 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Page 204 FORCE W Scheduler Set 06:00 - 16:00 16:00 - 21:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copy to the Next Day Save & Exit to confirm fig. 22 Scheduler Set 06:00 - 16:00 16:00 - 21:00 21:00 - 06:00 --:-- - --:-- --:-- - --:--...
  • Page 205 FORCE W Legionella programming (with optional hot water tank installed) To enable the Anti-legionella function it is necessary to set parameter P23, within the "TECHNICAL MENU, to ON. To program the function it is necessary to access the “Legionella” menu via the path “USER MENU “DHW”...
  • Page 206 FORCE W Holiday Function Access the "HOLIDAY FUNCTION" menu through the path "USER MENU “HOLIDAY FUNCTION” to set: • Holiday start date. • Holiday end date. The display can activate two types of icons: • - The Holiday function is programmed but not yet active. •...
  • Page 207 FORCE W Adjust the parallel offset of the curves from 20 to 60 °C (fig. 30), through the parameter “Offset1” and confirm with the OK button. OTC Offset 1 to confirm fig. 28 - Curve parallel offset If the room temperature is lower than the required value, it is advisable to set a higher order curve and vice versa. Pro- ceed by increasing or decreasing in steps of one and check the result in the room.
  • Page 208 FORCE W Adjustments from remote timer control If the Remote Timer Control (optional) is connected to the boiler, the above adjustments are managed accor- ding to that given in table 1. Table 1 The adjustment can be made from the Remote Timer Control menu and the boiler control Heating temperature adjustment panel.
  • Page 209 FORCE W 2. Installation 2.1 General Instructions BOILER INSTALLATION MUST ONLY BE PERFORMED BY QUALIFIED PERSONNEL, IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL MANUAL, THE PROVISIONS OF CURRENT LAW, THE PRESCRIPTIONS OF NATIONAL AND LOCAL STANDARDS AND THE RULES OF PROPER WORKMANSHIP. 2.2 Place of installation The generator must be installed in a suitable room with ventilation openings towards the outside in conformity with cu- rrent regulations.
  • Page 210 FORCE W High-efficiency circulating pump (optional) The factory setting is suitable for all installations; however a different operation strategy can be set with the speed se- lector (see fig. 32), depending on the characteristics of the system. 1 2 3 fig.
  • Page 211 FORCE W System water characteristics Before installing the FORCE W generator, the new or existing system must be properly cleaned in order to eliminate installation residues, solvents, sludge and contaminants in general that may compromise the effectiveness of the pro- tective conditioning treatments.
  • Page 212 FORCE W Table 2- Chemical conditioners declared suitable and available at our network of Authorized Tech- nical Assistance Centers Description Sentinel type alternative products Molybdenum-based corrosion inhibitor X100 LIFE PLUS/B - MOLY - MOLY K Noise reduction/anti-scaling maintenance X200 LIFE DUE Biocidal anti-algae X700 BIO KILL...
  • Page 213 FORCE W Optional kits The following kits are available on request: code 042070X0 - HIGH EFFICIENCY CIRCULATING PUMP KIT- 7m. (A - fig. 36) code 042071X0 - HIGH EFFICIENCY CIRCULATING PUMP KIT- 10m. (A - fig. 36) code 042072X0 - PLUMBING KIT The Kit 042072X0 contains: NON-RETURN VALVE - Female 1”1/2 (B - fig.
  • Page 214 FORCE W Hydraulic circuit examples In the examples described below, the checking/change of some parameters may be required. To do this it is necessary to access the Technical menu. From the Home page, press the main Menu button (detail 12 - fig. 1). Access the "Technical"...
  • Page 215 FORCE W Two direct heating circuits - Schematic diagram fig. 41 - Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 fig.
  • Page 216 FORCE W Legend (fig. 41 - fig. 42) 1st zone (direct) room thermostat 1st zone (direct) 2nd zone (direct) room thermostat 2nd zone (direct) External probe Delivery 1st zone (direct) circulating pump Return 2nd zone (direct) circulating pump ISPESL safety devices (when required - not supplied) To manage the sliding temperature it is necessary to purchase the external probe accessory code 013018X0 - Parameters Each system requires a different parameterization.
  • Page 217 FORCE W One direct heating circuit and one DHW circuit with circulating pump - Schematic diagram fig. 44 - Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44...
  • Page 218 FORCE W Legend (fig. 44 - fig. 45) 1st zone (direct) room thermostat 1st zone (direct) Hot water tank circulating pump Hot water tank circuit External probe Delivery Hot water tank probe Return Legionella protection circulating pump 1st zone (direct) circulating pump ISPESL safety devices (when required - not supplied) To manage the sliding temperature it is necessary to purchase the external probe accessory code 013018X0 If a hot water tank probe (not supplied) is used, it is necessary to purchase the NTC probe accessory code 1KWMA11W (2 mt.) or...
  • Page 219 FORCE W A direct heating circuit and a DHW circuit with diverter valve (3-wire) - Schematic diagram Use diverter valves with 3 wires: - 230V OPENING PHASE - 230V CLOSING PHASE - NEUTRAL with switching times (from all closed to all open) of not more than 90 seconds. fig.
  • Page 220 FORCE W Legend (fig. 46 - fig. 47) Heating circulating pump 1st zone (direct) 1st zone (direct) room thermostat Hot water tank circuit External probe Delivery Hot water tank probe Return 3-way valve (3-wire) A = OPENING PHASE B = NEUTRAL C = CLOSING PHASE ISPESL safety devices (when required - not supplied) To manage the sliding temperature it is necessary to purchase the external probe accessory code 013018X0...
  • Page 221 FORCE W Two mixed heating circuits, one direct heating circuit and one DHW circuit with circulating pump - Schematic diagram The zone control card FZ4B can manage different types of systems. An example is given. Use diverter valves with 3 wires: - 230V OPENING PHASE - 230V CLOSING PHASE - NEUTRAL...
  • Page 222 FORCE W - Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section. fig. 50 Legend 1st zone (mixed) room thermostat 1st zone (mixed) safety thermostat 317a 2nd zone (mixed) room thermostat 2nd zone (mixed) safety thermostat...
  • Page 223 FORCE W - Parameters Each system requires a different parameterization. Follow the access procedure given below. “Configuration - Parameters Menu” Check/Change parameter b02 of the “Configuration - Parameters Menu” to 9. Check/Change parameter b08 of the “Configuration - Parameters Menu” to 1. Check/Change parameter b04, b05 and b06 of the "Configuration - Parameters Menu"...
  • Page 224 FORCE W 2.4 Gas connection Before carrying out the connection, make sure the unit is arranged for operation with the type of fuel available and carefully clean all the pipes of the gas system to remove any residues that could affect proper boiler operation. The gas must be connected to the relevantconnection (see ) in conformity with the current standards, with a rigid metal pipe or with a continuous surface flexible s/steel tube, installing a gas cock between the system and boiler.
  • Page 225 FORCE W External probe (optional) Connect the probe to the respective terminals. The maximum permissible length of the electric cable connecting the boiler - external probe is 50 m. A common 2-wire cable can be used. The external probe should preferably be installed on the North, North-West wall or on the wall facing most of the main living-room.
  • Page 226 FORCE W 2.6 Fume ducts THE BOILERS MUST BE INSTALLED IN ROOMS THAT MEET THE FUNDA- MENTAL VENTILATION REQUIREMENTS. OTHERWISE THERE IS A DAN- GER OF ASPHYXIA OR POISONING. READ THE INSTALLATION AND MAINTENANCE INSTRUCTIONS BEFORE INSTALLING THE UNIT. ALSO RESPECT THE DESIGN INSTRUCTIONS. IN CASE OF PRESSURES EXCEEDING 200 Pa INSIDE THE FUME EXHAUST PIPES, THE USE OF CLASS "H1”...
  • Page 227 FORCE W Table 4Accessories table MODELS FORCE W FORCE W FORCE W FORCE W FORCE W Max permissible head (Pa) PIPE 1 M m/f 11.9 16.0 24.5 PIPE 0.5 M m/f 12.3 90° BEND Ø80 45° BEND 19.5 31.5 TERMINAL PIPE 1 M m/f PIPE 0.5 M m/f 90°...
  • Page 228 FORCE W 2.7 Condensate drain connection IMPORTANT The boiler has a trap to drain condensate. Proceed as follows for assembly. 1. Secure the trap. 2. Before connecting the hose to the discharge system, fill the trap with water. 3. Connect the hose from the trap to the condensate drain system. Drains connected to the drainage system must be resistant to acidic condensate.
  • Page 229 Personnel (meeting the professional technical requirements of current regulations) such as the personnel of the Local After-Sales Technical Service. FERROLI declines any liability for damage and/or injury caused by unqualified and unauthorized persons tampering with the unit. 3.1 Adjustments...
  • Page 230 FORCE W fig. 57- Models FORCE W 60 and FORCE W 80 fig. 58- Models FORCE W 99, FORCE W 120 and FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 231 FORCE W TEST mode activation Reach the screen shown in fig. 59, navigating the following menu path: "USER MENU Maintenance Test Mode Test mode”. The boiler will light, gradually reaching the maximum heating power (Range Rated) set as described in the next section. The display will show the actual heating power and that set.
  • Page 232 FORCE W Heating capacity adjustment diagram A = kW - B = Electronic Board Parameter fig. 60 TECHNICAL MENU ONLY QUALIFIED PERSONNEL CAN ACCESS THE SERVICE MENU AND MODIFY PARAMETERS. The Technical Menu can only be accessed after entering the code 4 1 8. It is valid for 15 minutes. Configuration - Parameters Menu There are 16 parameters, indicated by the letter “b”...
  • Page 233 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Parameter Description Range Not implemented Fumes Max Temperature 0-125°C Fan type selection Pump antiblock operation time 0-20 seconds Notes 1. Parameters with more than one description vary their function and/or range in relation to the setting of the parameter given in brackets.
  • Page 234 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Parameter Description Range With B02 = 7 - Not implemented With B02 = 8 - Legionella protection ON - OFF With B02 = 9 - Legionella protection ON - OFF Fan frequency in standby mode 0-255 Hz Modulating pump adjustment temperature...
  • Page 235 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Parameter Description Range 0-10Vdc Heating ON voltage (Tempera- 0.1-10 Vdc P.13 ture Control)** 0-10Vdc Max. voltage (Temperature Con- 0.1-10 Vdc P.14 trol)** 0-10Vdc Min. temperature (Temperature 0 ÷ 100°C P.15 Control)** 0-10Vdc Max.
  • Page 236 FORCE W • Check proper boiler lighting by doing several tests, turning it on and off with the room thermostat or remote control. • Using a combustion analyser connected to the boiler fume outlet, check that the CO content in the fumes, with the boiler operating at max.
  • Page 237 FORCE W Opening the front panel Some internal components of the boiler can reach high temperatures able to cause severe burns.Before carrying out any operation, allow these compo- nents to cool or, alternatively, wear appropriate gloves. To open the boiler casing: 1.
  • Page 238 FORCE W Extraordinary maintenance and replacement of components Electrode replacement Exchanger cleaning 3.4 Troubleshooting cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 239 FORCE W Diagnostics The boiler is equipped with an advanced self-diagnosis system. In case of a boiler fault, the display lights up indicating the fault code and, in case of cascade connection, the module number. • There are faults that cause permanent shutdowns which can be reset by pressing the OK button for one second or with the RESET button on the remote timer control (optional) if installed.
  • Page 240 FORCE W Fault Fault Possible cause Cure code Sensor damaged 12 DHW sensor fault Wiring shorted Check the wiring or replace the sensor Wiring disconnected Sensor damaged 13 Fume sensor fault Wiring shorted Check the wiring or replace the sensor Wiring disconnected Sensor damaged 14 Heating sensor 2 (Safety) fault...
  • Page 241 FORCE W 4. Technical data and characteristics Legend of figures cap. 4 "Technical data and characteristics" Gas inlet - Ø 1” System flow - Ø 1” 1/2 System return - Ø 1” 1/2 Safety valve Heating circulating pump (not supplied) Heating temperature sensor Automatic air vent Gas valve...
  • Page 242 FORCE W 4.1 Dimensions and connections fig. 62- Front view fig. 63- Side view fig. 64- Top view fig. 65- Bottom view - model FORCE W 60 and FORCE W 80 fig. 66- Bottom view - model FORCE W 99 and FORCE W 120 fig.
  • Page 243 FORCE W 4.2 General view fig. 68- General view - model FORCE W 60 and FORCE W 80 fig. 69- General view - model FORCE W 99 and FORCE W 120 fig. 70- General view - model FORCE W 150 cod.
  • Page 244 FORCE W 4.3 Hydraulic circuit fig. 71- Hydraulic circuit cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 245 FORCE W 4.4 Technical data table The column on the right gives the abbreviation used on the data plate. Model FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 PRODUCT IDENTIFICATION CODES 0MDLAAWA 0MDLCAWA 0MDLDAWA 0MDLEAWA 0MDLFAWA...
  • Page 246 FORCE W 4.5 ErP tables cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 247 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 248 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 249 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 250 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 251 FORCE W 4.6 Diagrams Pressure loss fig. 72- Pressure loss diagram - models FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 73- Pressure loss diagram - models FORCE W 150 Delivery - m cod.
  • Page 252 FORCE W 4.7 Wiring diagrams ATTENTION: Remove the jumper on the terminal block before connecting the room thermostat or remote timer control. fig. 74- Wiring diagram - models FORCE W 60 and FORCE W 80 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 253 FORCE W fig. 75- Wiring diagram - models FORCE W 99, FORCE W 120 and FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 254 FORCE W • Lire attentivement les avertissements repris dans le présent ge d'origine. Le non-respect de ce qui précède compromet les manuel d'instructions fournissant des indications importantes conditions de sécurité de l'appareil. pour la sécurité de l'installation, son utilisation et son entretien. •...
  • Page 255 FORCE W 1 Instructions d’utilisation ..................... 256 1.1 Introduction............................256 1.2 Tableau des commandes ........................256 1.3 Allumage et extinction ........................260 1.4 Réglages ............................261 2 Installation ..........................271 2.1 Dispositions générales ........................271 2.2 Emplacement ............................. 271 2.3 Raccordements hydrauliques ......................271 2.4 Raccordement gaz ..........................
  • Page 256 1.1 Introduction Cher Client, Nous vous remercions d'avoir choisi FORCE W, une chaudière murale FERROLI de conception avancée, de techno- logie d'avant-garde, de fiabilité élevée et de haute qualité constructive. Lire attentivement les instructions contenues dans la présente notice, car elles fournissent des indications importantes concernant la sécurité d'installation, l'utilisa- tion et l'entretien de l'appareil.
  • Page 257 FORCE W Touches directes Les touches directes (rep. 8, 9, 10 - fig. 1) ont toujours la même fonction. Touches de navigation/menu Les touches navigation/menu (rep. 5, 6, 7, 11, 12, 13 - fig. 1) servent à naviguer parmi les différents menus disponibles sur le panneau de contrôle.
  • Page 258 FORCE W ENTRETIEN Voir fig. 59 Mode Test Voir fig. 56 Mode Test Sélection type de gaz Voir Mode Test Cascade Voir “Information de Service” on page 268 Information Service Voir “Date Intervention Service” on page 268 Date Intervention Service CONFIGURATIONS Voir fig.
  • Page 259 FORCE W Exclusion du ballon (ECO) L'utilisateur peut exclure le chauffage/maintien de la température dans le ballon. En cas d'exclusion, l'eau chaude sa- nitaire ne sera pas disponible. Le ballon peut être désactivé par l'utilisateur (mode ECO) en appuyant sur la touche eco/ confort (rep.
  • Page 260 FORCE W 1.3 Allumage et extinction Allumage chaudière Appuyer sur la touche de Marche/Arrêt (rep. 14 - fig. 1). Display v.0X Module 1 v.0X fig. 7 - Arrêt chaudière Appuyer sur la touche contextuelle 1 pour choisir la langue et la confirmer en appuyant sur « OK ». Appuyer sur la touche contextuelle 3 pour interrompre le mode FH.
  • Page 261 FORCE W Accéder à la page qui s'affiche sur fig. 9 en naviguant à travers le menu à travers le parcours « MENU UTILISATEUR « Configurations » « Configuration Horaire ». Appuyer sur les touches de navigation 5 et 7 pour sélectionner la valeur et la modifier à...
  • Page 262 FORCE W L'afficheur allume le symbole Été. La fonction chauffage est désactivée mais la production éventuelle d'eau sanitaire (avec ballon externe optionnel) est activée. Le système antigel reste actif. Pour désactiver le mode Été, appuyer à nouveau sur la touche (rep.
  • Page 263 FORCE W Réglage Réduction température eau chaude sanitaire (avec ballon en option installé) Accès au menu « Temp Réglage » pour régler la température entre 10°C (minimum) et 65°C (maximum). Confirmer en appuyant sur OK. Température de consigne pour confirmer fig.
  • Page 264 FORCE W Programmation horaire La programmation de l'horaire suit la même procédure, qu'il s'agisse du chauffage ou de l'eau chaude sanitaire ; les deux programmes sont indépendants. Pour la programmation du Chauffage accéder au menu « Programme Horaire » à travers le parcours « MENU UTILI- SATEUR «...
  • Page 265 FORCE W Appuyer sur la touche de navigation 7 pour se placer sur l'heure à laquelle termine la première tranche horaire (fig. 19) et la définir sur la valeur choisie en utilisant les touches contextuelles 1 et 2. Programmation horaires 06:00 - 16:00 --:-- - --:--...
  • Page 266 FORCE W Programmation horaires 06:00 - 16:00 16:00 - 21:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copie sur jour suivant Enregistrer & Sortie pour confirmer fig. 22 Programmation horaires 06:00 - 16:00 16:00 - 21:00 21:00 - 06:00 --:-- - --:-- --:-- - --:--...
  • Page 267 FORCE W Programmation légionellose (avec ballon facultatif installé) Pour activer la Fonction anti-légionellose régler le paramètre P23, du MENU TECHNIQUE sur ON. Pour programmer la fonction entrer dans le menu « Légionellose » par le parcours MENU UTILISATEUR « EAU CHAUDE SANITAIRE »...
  • Page 268 FORCE W Fonction vacances Accéder au menu « FONCTION VACANCES » à travers le parcours « MENU UTILISATEUR « FONCTION VA- CANCES » pour pouvoir définir : • Date début Vacances. • Date fin Vacances. L'afficheur peut activer deux types d'icônes : •...
  • Page 269 FORCE W Régler le déplacement parallèle des courbes de 20 à 60 °C (fig. 30) à travers le paramètre « Offset1 » et confirmer en appuyant sur OK. Décalage paral. de pente 1 pour confirmer fig. 28 - Déplacement parallèle des courbes Si la température ambiante est inférieure à...
  • Page 270 FORCE W Réglages à partir de la chronocommande à distance Si la chaudière est reliée à la chronocommande à distance (option), les réglages ci-dessus seront gérés com- me indiqué dans le tableau tableau 1. Tableau 1 Le réglage peut être effectué à partir du menu de la chronocommande à distance ou directe- Réglage de la température de chauf- ment sur le tableau des commandes de la chaudière.
  • Page 271 FORCE W 2. Installation 2.1 Dispositions générales L'INSTALLATION DE LA CHAUDIÈRE DOIT ÊTRE EFFECTUÉE CONFORMÉMENT AUX TEXTES RÉGLEMENTAI- RES ET RÈGLES DE L'ART EN VIGUEUR, SUIVANT LES INSTRUCTIONS DU CONSTRUCTEUR ET PAR UN PRO- FESSIONNEL QUALIFIÉ. 2.2 Emplacement Le générateur doit être installé dans un local approprié, muni d'ouvertures d'aération vers l'extérieur, conformément aux normes en vigueur.
  • Page 272 FORCE W Circulateur haute efficacité (en option) La configuration standard s'adapte à tous les types d'installation ; il est toutefois possible de définir un mode de fonc- tionnement différent en fonction des caractéristiques de l'installation à travers le sélecteur de vitesse (voir fig. 32) . 1 2 3 fig.
  • Page 273 FORCE W Caractéristiques de l'eau de l'installation Avant de procéder à l'installation du générateur FORCE W, l'installation, nouvelle ou existante, doit être correctement nettoyée afin d'éliminer les résidus d'installation, les solvants, les boues et les contaminants en général pouvant em- pêcher l'efficacité...
  • Page 274 FORCE W Vérifiez toujours la concentration du produit après chaque introduction et de ma- nière cyclique, au moins une fois par an, à l’aide d’un personnel technique qualifié tel que celui de notre réseau d'assistance technique agréé. Tableau 2- Les agents de conditionnement chimiques déclarés appropriés et disponibles auprès de notre réseau de centres d'assistance technique agréés Description Produits alternatifs type Sentinel...
  • Page 275 FORCE W composants et/ou matériaux de la chaudière et de l'installation. Il est interdit d'utiliser des liquides antigel, des additifs et des inhibiteurs non spécifiquement prévus pour l'utilisation dans des circuits thermiques et compatibles avec les ma- tériaux composant la chaudière et le circuit. Kit options Sur demande, les kits suivants sont disponibles : réf.
  • Page 276 FORCE W Exemples de circuits hydrauliques Dans les exemples décrits ci-après, il pourrait être nécessaire de vérifier/modifier certains paramètres. Pour cela, accéder d'abord au menu Technicien. À partir de la page principale (Accueil), appuyer sur la touche Menu principal (rep. 12 - fig. 1). Accéder au menu «...
  • Page 277 FORCE W Deux circuits chauffage directs - Schéma de principe fig. 41 - Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 fig.
  • Page 278 FORCE W Légende (fig. 41 - fig. 42) Thermostat d'ambiance 1ère zone (directe) 1ère zone (directe) Thermostat d'ambiance 2e zone (directe) 2ème zone (directe) Sonde extérieure Départ Circulateur 1ère zone (directe) Retour Circulateur 2e zone (directe) Dispositifs de sécurité ISPESL (Si nécessaires - non fournis) Pour contrôler la température évolutive, commander l'accessoire sonde extérieure, réf.
  • Page 279 FORCE W Un circuit chauffage direct et un circuit eau chaude sanitaire avec circulateur - Schéma de principe fig. 44 - Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44...
  • Page 280 FORCE W Légende (fig. 44 - fig. 45) Thermostat d'ambiance 1ère zone (directe) 1ère zone (directe) Circulateur ballon Circuit ballon Sonde extérieure Départ Sonde ballon Retour Circulateur anti-légionellose Circulateur 1ère zone (directe) Dispositifs de sécurité ISPESL (Si nécessaires - non fournis) Pour contrôler la température évolutive, commander l'accessoire sonde extérieure, réf.
  • Page 281 FORCE W Un circuit chauffage direct et un circuit eau chaude sanitaire avec by-pass (3 fils) - Schéma de principe Utiliser des by-pass à 3 fils : - PHASE D’OUVERTURE 230 V - PHASE DE FERMETURE 230 V - NEUTRE avec temps de commutation (de fermé...
  • Page 282 FORCE W Légende (fig. 46 - fig. 47) Circulateur circuit chauffage 1ère zone (directe) Thermostat d'ambiance 1ère zone (directe) Circuit ballon Sonde extérieure Départ Sonde ballon Retour Vanne 3 voies (trois fils) A = PHASE D'OUVERTURE B = NEUTRE C = PHASE DE FERMETURE Dispositifs de sécurité...
  • Page 283 FORCE W Deux circuits chauffage mélangés, un circuit chauffage direct et un circuit eau chaude sanitaire avec circulateur - Schéma de principe La carte contrôle zones FZ4B peut commander plusieurs types d'installation. Type d'installation cité comme exemple. Utiliser des by-pass à 3 fils : - PHASE D’OUVERTURE 230 V - PHASE DE FERMETURE 230 V - NEUTRE...
  • Page 284 FORCE W - Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant. fig. 50 Légende Thermostat d'ambiance 1ère zone (mélangée) Thermostat de sécurité 1ère zone (mélangée) 317a Thermostat d'ambiance 2e zone (mélangée) Thermostat de sécurité...
  • Page 285 FORCE W - Paramètres Chaque circuit doit être configuré individuellement. Suivre la procédure d'accès indiquée ci-après. « Menu Paramètres - Configuration » Vérifier/Modifier paramètre b02 du « Menu Paramètres - Configuration » sur 9. Vérifier/Modifier paramètre b08 du « Menu Paramètres - Configuration » sur 1. Vérifier/Modifier paramètre b04, b05 et b06 du «...
  • Page 286 FORCE W 2.4 Raccordement gaz Avant d'effectuer le raccordement, veiller à ce que l'appareil soit préparé pour fon- ctionner avec le type de combustible disponible et prendre soin de bien nettoyer les conduites du circuit afin d'en retirer tout résidu pouvant compromettre le bon fonctionnement de la chaudière.
  • Page 287 FORCE W Thermostat d'ambiance (en option) ATTENTION : LE THERMOSTAT D'AMBIANCE DOIT ÊTRE À CONTACTS PRO- PRES. EN RELIANT 230 V. AUX BORNES DU THERMOSTAT, LA CARTE ÉLECTRONIQUE EST IRRÉMÉDIABLEMENT DÉTÉRIORÉE. En raccordant une chronocommande ou un interrupteur horaire (minuterie), éviter d'utiliser l'alimentation de ces dispositifs à...
  • Page 288 FORCE W La puissance du relais de sortie du circulateur chauffage (32 de la fig. 74 et la fig. 75) correspond à 8A@230Vca. La puissance du relais de sortie de la soupape de déviation ou bipasse (95 de la fig. 74 et la fig. 75) correspond à 5A@230Vca. En cas d'absorption supérieure de la part des charges, installer des relais de sup- port avec des protections supplémentaires.
  • Page 289 FORCE W Tableau 4Tableau des accessoires MODÈLES FORCE W FORCE W FORCE W FORCE W FORCE W Hauteur d’élévation maximale auto- risée (Pa) TUYAU 1 M m/f 11,9 16,0 24,5 TUYAU 0.5 M m/f 12,3 COUDE 90° Ø80 COUDE 45° 19,5 31,5 TERMINAL...
  • Page 290 FORCE W 2.7 Raccordement de l'évacuation de la condensation AVERTISSEMENTS La chaudière est munie de siphon interne pour l'évacuation des condensats. Suivre les instructions suivantes pour ef- fectuer le montage. 1. Fixer le siphon. 2. Avant de brancher le tuyau flexible au circuit de remplissage, remplir le siphon d’eau. 3.
  • Page 291 SAV. FERROLI Toute responsabilité contractuelle et extracontractuelle du constructeur est exclue pour les dommages causés par des erreurs dans l'installation et l'utilisation et, dans tous les cas, par le non-respect des instructions fournies par le constructeur.
  • Page 292 FORCE W fig. 57- Modèles FORCE W 60 et FORCE W 80 fig. 58- Modèles FORCE W 99, FORCE W 120 et FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 293 FORCE W Activation du mode TEST Accéder à la page qui s'affiche sur fig. 59 en naviguant dans le menu en suivant le chemin « MENU UTILISATEUR Entretien Mode Test Mode test ». La chaudière s'allume à la puissance maximale de chauffage (Range Rated) fixée, comme l'indique le paragraphe sui- vant, de façon progressive.
  • Page 294 FORCE W Diagramme de réglage de la puissance thermique A = kW - B = Paramètre carte électronique fig. 60 MENU TECHNICIEN L’ACCÈS AU MENU SERVICE ET LA MODIFICATION DES PARAMÈTRES NE PEUVENT ÊTRE EFFECTUÉS QUE PAR UN PERSONNEL QUALIFIÉ. L'accès au Menu Technicien n'est possible qu'après avoir saisi le code 4 1 8.
  • Page 295 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Paramètre Description Plage Post-ventilation 0-120 secondes Pré-ventilation chaufferie 1-15 minutes Post-ventilation chaufferie 1-15 minutes OFF=Désactivé, Capteur des fumées ON=Activé Non prévu Température maxi des fumées 0-125 °C Sélection du type de ventilateur Temps de fonctionnement antiblo- 0-20 secondes cage pompe...
  • Page 296 FORCE W FORCE W FORCE W FORCE FORCE W FORCE Paramètre Description Plage W 99 W 150 Avec B02 = 7 - Non prévu Avec B02 = 8 - Hystérésis ballon 0° ÷ 60° 2° 2° 2° 2° 2° Avec B02 = 9 - Hystérésis ballon 0°...
  • Page 297 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Paramètre Description Plage Puissance désactiva- 0 ÷ 100 % P.08 tion* Fonction séparateur OFF = Désactivé, ON = Activé P.09 hydraulique Fonction remplissage OFF = Désactivé, ON = Activé P.10 circuit d'eau 2/3 = 2 ou 3 fils...
  • Page 298 FORCE W Avant d'allumer la chaudière • Ouvrir les éventuelles vannes d'arrêt entre la chaudière et les installations. • Vérifier l'étanchéité de l'installation de gaz en procédant avec prudence et en utilisant une solution aqueuse pour détecter les fuites éventuelles au niveau des raccords. •...
  • Page 299 FORCE W • Contrôle et nettoyage des électrodes qui ne doivent présenter aucune trace de tartre et être installées correctement. • Contrôle des joints (brûleur, chambre étanche, etc.). • Contrôle et nettoyage des filtres désemboueurs et des filtres le long du circuit. •...
  • Page 300 FORCE W Entretien extraordinaire et remplacement des composants Remplacement de l’électrode Nettoyage de l’échangeur 3.4 Dépannage cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 301 FORCE W Diagnostic La chaudière est équipée d'un dispositif d'autodiagnostic avancé. Dans le cas d’anomalie ou de dysfonctionnement de la chaudière, l’afficheur s’illumine indiquant le code d'erreur et, dans le cas de raccordement en cascade, le numéro du module. • Certaines anomalies provoquant des blocages permanents peuvent être corrigées soit par appui sur la touche OK pendant une seconde, soit par pression de la touche RESET de la chronocommande à...
  • Page 302 FORCE W Code Anomalie Causes probables Solution anomalie Capteur endommagé Anomalie capteur d'eau Câblage en court-circuit Contrôler le câblage ou remplacer le capteur chaude sanitaire Câblage interrompu Capteur endommagé Anomalie capteur des Câblage en court-circuit Contrôler le câblage ou remplacer le capteur fumées Câblage interrompu Capteur endommagé...
  • Page 303 FORCE W 4. Caractéristiques et données techniques Légende des figures cap. 4 "Caractéristiques et données techniques" Arrivée gaz - Ø 1” Départ installation - Ø 1” 1/2 Retour installation - Ø 1” 1/2 Soupape de sécurité Ventilateur Circulateur circuit chauffage (non fourni) Capteur de température chauffage Purgeur d’air automatique Vanne à...
  • Page 304 FORCE W 4.1 Dimensions et raccords fig. 62- Vue de face fig. 63- Vue latérale fig. 64- Vue de dessus fig. 65- Vue de dessous mod. FORCE W 60 et FORCE W 80 fig. 66- Vue de dessous mod. FORCE W 99 et FORCE W 120 fig.
  • Page 305 FORCE W 4.2 Vue générale fig. 68- Vue générale mod. FORCE W 60 et FORCE W 80 fig. 69- Vue générale mod. FORCE W 99 et FORCE W 120 fig. 70- Vue générale mod. FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 306 FORCE W 4.3 - Circuit hydraulique fig. 71- Circuit hydraulique cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 307 FORCE W 4.4 Tableau des caractéristiques techniques La colonne de droite indique l'abréviation utilisée sur la plaquette des caractéristiques techniques. FORCE W FORCE W FORCE W FORCE W FORCE W Modèle CODES D'IDENTIFICATION DES PRODUITS 0MDLAAWA 0MDLCAWA 0MDLDAWA 0MDLEAWA 0MDLFAWA PAYS DE DESTINATION IT ES RO RU PL BG DE GR HR LV UA CATÉGORIE DE GAZ...
  • Page 308 FORCE W 4.5 Tableaux ErP cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 309 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 310 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 311 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 312 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 313 FORCE W 4.6 Diagrammes Perte de charge fig. 72- Diagramme perte de charge modèles FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 73- Diagramme perte de charge modèles FORCE W 150 Débit - m cod.
  • Page 314 FORCE W 4.7 Schémas électriques ATTENTION ! Avant de brancher le thermostat d'ambiance ou la chronocommande à distance, défaire le pon- tage sur le bornier. fig. 74- Schéma électrique modèles FORCE W 60 et FORCE W 80 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 315 FORCE W fig. 75- Schéma électrique modèles FORCE W 99, FORCE W 120 et FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 316 FORCE W • Данный символ означает "Осторожно" и сопровождает все указания, касающиеся безопасности. Строго придерживайтесь таких указаний во избежание опасности вреда для здоровья людей и животных и материального ущерба. Макс. теплопроизводительность системы ГВС (Hi) Qnw (Hi) Manufacturer / Производитель: Manufacturer address: Данный...
  • Page 317 FORCE W 1 Инструкции по эксплуатации................... 318 1.1 Предисловие ............................. 318 1.2 Панель управления .......................... 318 1.3 Включение и выключение ........................ 322 1.4 Регулировки ............................323 2 Установка агрегата......................333 2.1 Указания общего характера......................333 2.2 Место установки ..........................333 2.3 Гидравлические подключения ......................333 2.4 Газовые...
  • Page 318 1.1 Предисловие Уважаемый покупатель! Благодарим Вас за то, что Вы выбрали FORCE W, настенный котел FERROLI самой современной конструкции, выполненный с использованием самых передовых технологий и отличающийся высокой надежностью и качеством изготовления. Просим Вас внимательно прочитать настоящее руководство, поскольку в нем содержатся важные указания по безопасности...
  • Page 319 FORCE W Однозначные клавиши Однозначные клавиши (поз. 8, 9, 10 - рис. 1) всегда выполняют одну и ту же функцию. Клавиши навигации/меню Клавиши навигации/меню (поз. 5, 6, 7, 11, 12, 13 - рис. 1) служат для навигации между разными меню на панели управления. Структура...
  • Page 320 FORCE W ТЕХОБСЛУЖИВАНИЕ См. рис. 59 Тестовый режим См. рис. 56 Выбор типа газа Тестовый режим Тестовый режим Каскадной См. схемы См. “Информация о Сервисной службе” on page 330 Сервисная информация См. “Дата проведения сервисных операций” on page 330 Дата проведения сервисных операций НАСТРОЙКИ...
  • Page 321 FORCE W Исключение бойлера (режим Еconomy) Пользователь имеет возможность исключать систему нагрева/поддержания температуры воды в бойлере. В случае исключения этой системы из работы вода ГВС не будет вырабатываться. Бойлер может быть отключен пользователем (режим Экономии - ECO) путем нажатия на клавишу Экономия/Комфорт (поз. 10 - рис. 1). В режиме Экономии - ECO на дисплее...
  • Page 322 FORCE W 1.3 Включение и выключение Включение котла Нажмите на кнопку включения/выключения (поз. 14 - рис. 1). Display v.0X Burner Controller 1 v.0X рис. 7 - Включение котла Нажатием на контекстную клавишу 1 можно выбрать требуемый язык и подтвердить выбор с помощью клавиши “OK”. Нажатием...
  • Page 323 FORCE W Войдите в экранное окно, показанное на рис. 9, выбрав навигацию в меню по следующему маршруту “МЕНЮ ПОЛЬЗОВАТЕЛЯ “Установки” “Установка расписания”. Нажмите на клавиши навигации 5 и 7, чтобы выбрать значение, и затем с помощью контекстных клавиш 1 и 2 можно его изменить. Подтвердите выбор клавишей OK. Set time : 59 to select...
  • Page 324 FORCE W Чтобы отключить режим Лето, повторно нажмите на кнопку (поз. 9 - рис. 1) в течение 1 секунды. 23°C 32°C Thursday 9 Jan. 2014 11:33:03 рис. 11 - Лето Регулировка температуры воды в системе отопления Войдите в меню “Темп. регулировка”, чтобы изменить температуру в диапазоне от минимальной 20°C до максимальной 80°. Подтвердите...
  • Page 325 FORCE W Регулировка Уменьшение температуры ГВС (с установленным факультативным бойлером) Войдите в меню “Темп. регулировка”, чтобы изменить температуру в диапазоне от минимальной 10°C до максимальной 65°C. Подтвердите с помощью кнопки OK. CH setpoint to confirm рис. 14 На момент продажи программа с графиком работы котла не активирована. Следовательно, в...
  • Page 326 FORCE W Программирование графика работы по часам Программирование графика работы по часам осуществляется одинаковым способом для системы отопления и ГВС; две программы являются независимыми. Для программирования режима отопления войти в меню “График работы” следуя маршруту “МЕНЮ ПОЛЬЗОВАТЕЛЯ “ОТОПЛЕНИЕ” “График работы”. Для...
  • Page 327 FORCE W Нажатием на клавишу навигации 7 перейдите на расписание окончания первого временного диапазона (рис. 19) и задайте его на требуемое значение с помощью контекстных клавиш 1 и 2. Scheduler Set 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Page 328 FORCE W Scheduler Set 06:00 - 16:00 16:00 - 21:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copy to the Next Day Save & Exit to confirm рис. 22 Scheduler Set 06:00 - 16:00 16:00 - 21:00 21:00 - 06:00 --:-- - --:-- --:-- - --:--...
  • Page 329 FORCE W Programmazione Legionella (con bollitore opzionale installato) Per abilitare la Funzione Antilegionella и necessario settare il parametro P23, all’interno del “MENЩ TECNICO, su ON. Per programmare la funzione и necessario accedere al menщ “Legionella” attraverso il percorso “MENЩ UTENTE “ACQUA CALDA SANITARIA”...
  • Page 330 FORCE W Функция отпуска Войдите в меню “ФУНКЦИЯ ОТПУСКА” по маршруту “МЕНЮ ПОЛЬЗОВАТЕЛЯ “ФУНКЦИЯ ОТПУСКА”, чтобы задать: • Дату начала отпуска. • Дату окончания отпуска. На дисплее могут появится два типа иконок: • - Функция Отпуска запрограммирована, но не активирована. •...
  • Page 331 FORCE W Отрегулируйте параллельное перемещение кривых от 20 до 60 °C (рис. 30) с помощью параметра “Сдвиг1” и подтвердите с помощью клавиши OK. OTC Offset 1 to confirm рис. 28 - Параллельное перемещение кривых Если температура в помещении оказывается ниже желаемой, рекомендуется выбрать кривую более высокого порядка и наоборот.
  • Page 332 FORCE W Регулировка с дистанционного пульта управления с таймером Если к котлу подключено устройство дистанционного управления с таймером (опция), вышеописанные регулировки производятся в соответствии с указаниями, приведенными в таблица 1. Таблица 1 Регулировку можно осуществлять как через меню пульта ДУ с таймером, так и с панели Регулировка...
  • Page 333 FORCE W 2. Установка агрегата 2.1 Указания общего характера УСТАНОВКА И НАСТРОЙКА ГОРЕЛКИ ДОЛЖНА ОСУЩЕСТВЛЯТЬСЯ ТОЛЬКО СПЕЦИАЛИЗИРОВАННЫМ ПЕРСОНАЛОМ, ИМЕЮЩИМ ПРОВЕРЕННУЮ КВАЛИФИКАЦИЮ, ПРИ СОБЛЮДЕНИИ ПРИВЕДЕННЫХ В НАСТОЯЩЕМ ТЕХНИЧЕСКОМ РУКОВОДСТВЕ УКАЗАНИЙ, ПРЕДПИСАНИЙ ДЕЙСТВУЮЩЕГО ЗАКОНОДАТЕЛЬСТВА, ПОЛОЖЕНИЙ МЕСТНЫХ НОРМ И ПРАВИЛ, И В СООТВЕТСТВИИ С ПРИНЯТЫМИ ТЕХНИЧЕСКИМИ ТРЕБОВАНИЯМИ. 2.2 Место...
  • Page 334 FORCE W Высокопроизводительный циркуляционный насос (опция) Заводская настройка подходит для всех установок; тем не менее, с помощью регулятора скорости (см. рис. 32), можно задавать иную стратегию работы в зависимости от характеристик системы. 1 2 3 рис. 32 Настройка Dp-v Настройка Dp-c Настройка...
  • Page 335 FORCE W Характеристики воды в системе Перед установкой генератора FORCE W система, будь она новой или уже эксплуатируемой, должна быть должным образом очищена, чтобы удалить загрязнения, оставшиеся после монтажа, растворители, шлам и загрязняющие вещества в целом, поскольку они могут нарушить эффективность защитных кондиционирующих присадок. Используйте нейтральные неагрессивные...
  • Page 336 FORCE W Таблица 2- Рекомендуемые химические кондиционирующие присадки, доступные в нашей авторизованной сервисной сети Альтернативные средства типа Описание Sentinel Антикоррозийное средство на основе молибдена X100 LIFE PLUS/B - MOLY - MOLY K Шумоподавление/профилактическая защита от X200 LIFE DUE накипи Биоцидное противоводорослевое средство X700 BIO KILL Пропиленовый...
  • Page 337 FORCE W Дополнительные комплекты оснащения По заказу поставляются следующие комплекты: код 042070X0 - КОМПЛЕКТ ВЫСОКОПРОИЗВОДИТЕЛЬНОГО ЦИРКУЛЯЦИОННОГО НАСОСА - 7 м (A - рис. 36) код 042071X0 - КОМПЛЕКТ ВЫСОКОПРОИЗВОДИТЕЛЬНОГО ЦИРКУЛЯЦИОННОГО НАСОСА - 10 м (A - рис. 36) код 042072X0 - ГИДРАВЛИЧЕСКИЙ КОМПЛЕКТ В...
  • Page 338 FORCE W Примеры гидравлических контуров В нижеприведенных примерах может потребоваться проверить/изменить некоторые параметры. Для этого необходимо войти в меню «Техника». В главном экранном окне (Home) нажмите на клавишу «Главного меню» (поз. 12 - рис. 1). Войдите в меню “Техника" путем нажатия на контекстную клавишу 2 (поз. 2 - рис. 1). MENU USER TECHNICIAN...
  • Page 339 FORCE W Два прямых контура отопления - Принципиальная схема рис. 41 - Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 рис.
  • Page 340 FORCE W Список обозначений (рис. 41 - рис. 42) Комнатный термостат 1-й зоны (прямого контура) 1-я зона (прямой контур) Комнатный термостат 2-й зоны (прямого контура) 2-я зона (прямой контур) Датчик наружной температуры воздуха Линия подачи м Циркуляционный насос 1-й зоны (прямого контура) Обратный...
  • Page 341 FORCE W Прямой отопительный контур и контур ГВС с циркуляционным насосом. - Принципиальная схема рис. 44 - Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44...
  • Page 342 FORCE W Список обозначений (рис. 44 - рис. 45) Комнатный термостат 1-й зоны (прямого контура) 1-я зона (прямой контур) Циркуляционный насос бойлера Контур бойлера Датчик наружной температуры воздуха Линия подачи м Датчик бойлера Обратный контур Циркуляционный насос против легионеллы Циркуляционный насос 1-й зоны (прямого контура) Предохранительные...
  • Page 343 FORCE W Прямой отопительный контур и контур ГВС с распределительным клапаном (3-проводной) - Принципиальная схема Используйте 3-проводные отводящие клапаны: - ФАЗА РАЗМЫКАНИЯ 230 В - ФАЗА ЗАМЫКАНИЯ 230 В - НЕЙТРАЛЬНАЯ ФАЗА со временем переключения (от полностью замкнутого до полностью разомкнутого) не более 90 секунд. рис.
  • Page 344 FORCE W Список обозначений (рис. 46 - рис. 47) Циркуляционный насос системы отопления 1-я зона (прямой контур) Комнатный термостат 1-й зоны (прямого контура) Контур бойлера Датчик наружной температуры воздуха Линия подачи м Датчик бойлера Обратный контур 3-ходовой клапан (трехпроводной) A = ФАЗА РАЗМЫКАНИЯ B = НЕЙТРАЛЬНАЯ...
  • Page 345 FORCE W Два отопительных контура со смесительным клапаном, прямой отопительный контур и контур ГВС с циркуляционным насосом - Принципиальная схема Плата контроля зон FZ4B может управлять отопительными системами различных типов. На рисунке приводится пример. Используйте 3-проводные отводящие клапаны: - ФАЗА РАЗМЫКАНИЯ 230 В - ФАЗА...
  • Page 346 FORCE W - Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа. рис. 50 Список обозначений Комнатный термостат 1-й зоны (со смесительным Предохранительный термостат 1-й зоны (со 317a клапаном) смесительным...
  • Page 347 FORCE W - Параметры Каждая система нуждается в различной настройке параметров. Необходимо следовать приведенной далее процедуре. Меню "Параметры - Конфигурация" Проверьте/измените параметр b02 в меню "Параметры - Конфигурация" на 9. Проверьте/измените параметр b08 в меню "Параметры - Конфигурация" на 1. Проверьте/измените...
  • Page 348 FORCE W 2.4 Газовые соединения Перед выполнением подключения удостоверьтесь, что котел отрегулирован для работы на имеющемся в Вашей магистрали газе и тщательно прочистите все газовые трубы для удаления остаточных загрязнений или посторонних включений, могущих помешать правильной работе агрегата. Газ подключается к соответствующему патрубку (см. ) с...
  • Page 349 FORCE W Термостат комнатной температуры ВНИМАНИЕ: ТЕРМОСТАТ КОМНАТНОЙ ТЕМПЕРАТУРЫ ДОЛЖЕН БЫТЬ УСТРОЙСТВОМ С КОНТАКТАМИ НЕ ПОД НАПРЯЖЕНИЕМ. ПРИ ПОДАЧЕ НАПРЯЖЕНИЯ В НА КЛЕММЫ ТЕРМОСТАТА КОМНАТНОЙ ТЕМПЕРАТУРЫ ПОВЛЕЧЕТ ЗА СОБОЙ НЕПОДЛЕЖАЩЕЕ РЕМОНТУ ПОВРЕЖДЕНИЕ ЭЛЕКТРОННОЙ ПЛАТЫ. При подключении регуляторов комнатной температуры с повременной программой...
  • Page 350 FORCE W Реле на выходе циркуляционного насоса системы отопления (32рис. 74 и рис. 75) меет пропускную способность равную 8A@230 В пер. тока. и Реле на выходе отводящего клапана (95рис. 74 рис. 75) меют пропускную и и способность равную 5A@230 В пер. тока. В...
  • Page 351 FORCE W Таблица 4Таблица принадлежностей МОДЕЛИ FORCE W FORCE W FORCE W FORCE W FORCE W Максимально допустимый напор (Па) ТРУБА 1 М с внешн./внутр. резьбой 11,9 16,0 24,5 ТРУБА 0,5 М с внешн./внутр. 12,3 резьбой Ø80 КОЛЕНО 90° КОЛЕНО 45° 19,5 31,5 ОГОЛОВОК...
  • Page 352 FORCE W 2.7 Подсоединение трубы для слива конденсата ПРЕДУПРЕЖДЕНИЯ И МЕРЫ ПРЕДОСТОРОЖНОСТИ Котел оборудован сифоном для слива конденсата. Придерживайтесь следующих инструкций для выполнения монтажа. 1. Закрепите сифон. 2. Перед подключением шланга к выпускной системе заполните сифон водой. 3. Подсоедините шланг от сифона к системе слива конденсата. Стоки, подключенные...
  • Page 353 техническим требованиям, предусмотренным действующим законодательством), таких как сотрудники обслуживающего вашу территорию сервисного центра. FERROLI снимает с себя всякую ответственность за травмы и/или материальный ущерб, нанесенный в результате несанкционированного вмешательства в конструкцию агрегата со стороны неквалифицированных и неуполномоченных лиц. 3.1 Регулировки...
  • Page 354 FORCE W рис. 57- Модели FORCE W 60 и FORCE W 80 рис. 58- Модели FORCE W 99, FORCE W 120 и FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 355 FORCE W Активация тестового режима TEST Войдите в окно, изображенное на рис. 59, двигаясь в меню по маршруту "МЕНЮ ПОЛЬЗОВАТЕЛЯ Обслуживание Режим тестирования Режим тестирования". Котел включается, постепенно достигая максимальной мощности отопления (Range Rated), которая задается в соответствии с указаниями из следующего параграфа. На...
  • Page 356 FORCE W Диаграмма регулировки расхода тепла A = кВт - B = Параметр электронной платы рис. 60 МЕНЮ ТЕХНИКА ДОСТУП К СЕРВИСНОМУ МЕНЮ И ИЗМЕНЕНИЕ ПАРАМЕТРОВ ДОЛЖНО ВЫПОЛНЯТЬСЯ ТОЛЬКО КВАЛИФИЦИРОВАННЫМ ПЕРСОНАЛОМ. Доступ в меню «Техника» возможен только после ввода кода 4 1 8. Он действует в течение 15 минут. Меню...
  • Page 357 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Параметр Описание Диапазон Предв. вентиляция помещения 1-15 минут котла Пост-вентиляция помещения 1-15 минут котла ВЫКЛ.=отключен, Датчик дыма ВКЛ. ВКЛ. ВКЛ. ВКЛ. ВКЛ. ВКЛ.=включен Не используется Максимальная температура 0-125°C дымов...
  • Page 358 FORCE W FORCE FORCE FORCE FORCE W FORCE W Параметр Описание Диапазон W 60 W 80 W 99 При B02 = 7 - Не используется При B02 = 8 - Гистерезис бойлера 0° ч 60° 2° 2° 2° 2° 2° При...
  • Page 359 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Параметр Описание Диапазон Мощность активации* 0 ч 100% P.07 Мощность дезактивации* 0 ч 100% P.08 Функция гидравлического ВЫКЛ. = отключена, ВКЛ. = включена ВЫКЛ. ВЫКЛ. ВЫКЛ. ВЫКЛ. ВЫКЛ. P.09 сепаратора...
  • Page 360 FORCE W • Наполните сифон системы отвода конденсата и проверьте правильность соединения его со сливом. • Удостоверьтесь в отсутствии утечек воды в системе отопления, в контуре ГВС, в местах соединений или в котле. • Проверьте правильность выполнения электрических соединений и эффективность заземления. •...
  • Page 361 FORCE W • Проверка и очистка системы вывода продуктов сгорания «воздуховод-коллектор-дымоход». • Проверка и предварительная зарядка расширительных бачков. • Проверка правильного и устойчивого давления воды в системе, проверка его соответствия рабочему давлению, предусмотренному в центральной сети водоснабжения. В используемых системах автоматической загрузки для восстановления рабочих...
  • Page 362 FORCE W Внеплановое техническое обслуживание и замена компонентов Замена электрода Чистка теплообменника 3.4 Устранение неисправностей cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 363 FORCE W Диагностика Котел оснащен современной системой самодиагностики. В случае сбоя в работе котла на дисплее появляется код неисправности, а в случае каскадного подключения - номер модуля. • Существуют неполадки, вызывающие постоянную блокировку, которую можно сбросить нажатием на секунду кнопки OK или...
  • Page 364 FORCE W Код Неисправность Возможная причина Способ устранения неисправности Датчик поврежден Неисправность датчика на Короткое замыкание в соединительном проводе Проверьте кабель датчика или замените датчик обратном трубопроводе Обрыв соединительного провода Датчик поврежден Неисправность датчика температуры воды в Короткое замыкание в соединительном проводе Проверьте...
  • Page 365 FORCE W 4. Характеристики и технические данные Обозначения cap. 4 "Характеристики и технические данные" Вход газа - Ш1" Подача в систему - Ш1" 1/2 Возврат из системы - Ш1" 1/2 Предохранительный клапан Вентилятор Циркуляционный насос системы отопления (не входит в поставку) Датчик...
  • Page 366 FORCE W 4.1 Размеры и соединения рис. 62- Вид спереди рис. 63- Вид сбоку рис. 64- Вид сверху рис. 65- Вид снизу, мод. FORCE W 60 и FORCE W 80 рис. 66- Вид снизу, мод. FORCE W 99 и FORCE W 120 рис.
  • Page 367 FORCE W 4.2 Общий вид рис. 68- Общий вид, мод. FORCE W 60 и FORCE W 80 рис. 69- Общий вид, мод. FORCE W 99 и FORCE W 120 рис. 70- Общий вид, мод. FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 368 FORCE W 4.3 Гидравлический контур рис. 71- Гидравлический контур cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 369 FORCE W 4.4 Таблица технических данных В правом столбце указывается сокращение, используемое на табличке с техническими данными. Модель FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 ИДЕНТИФИКАЦИОННЫЕ КОДЫ ИЗДЕЛИЙ 0MDLAAWA 0MDLCAWA 0MDLDAWA 0MDLEAWA 0MDLFAWA СТРАНЫ...
  • Page 370 FORCE W 4.5 Диаграммы Потеря нагрузки рис. 72- Диаграмма потери нагрузки для моделей FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 рис. 73- Диаграмма потери нагрузки для моделей FORCE W 150 Расход - м /ч...
  • Page 371 FORCE W рис. 74- Электрическая схема моделей FORCE W 60 и FORCE W 80 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 372 FORCE W рис. 75- Электрическая схема моделей FORCE W 99, FORCE W 120 и FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 373 FORCE W • Należy uważnie przeczytać ostrzeżenia zawarte w niniejszej odpowiednimi kwalifikacjami zawodowymi i wyłącznie przy instrukcji, ponieważ zawiera ona ważne wskazówki użyciu oryginalnych części zamiennych Nieprzestrzeganie dotyczące bezpieczeństwa podczas montażu, eksploatacji i powyższych zaleceń może negatywnie wpłynąć na bezpiec- konserwacji.
  • Page 374 FORCE W 1 Instrukcja obsługi ........................ 375 1.1 Prezentacja ............................375 1.2 Panel sterowania ..........................375 1.3 Zapłon i wyłączanie ..........................379 1.4 Regulacje ............................380 2 Instalacja..........................390 2.1 Zalecenia ogólne ..........................390 2.2 Miejsce instalacji ..........................390 2.3 Podłączenia hydrauliczne........................390 2.4 Podłączenie gazu ..........................
  • Page 375 1.1 Prezentacja Szanowny Kliencie! Dziękujemy za wybranie FORCE W, kotła naściennego marki FERROLI o zaawansowanym projekcie, awangardowej technologii oraz wysokiej niezawodności i jakości wykonania. Prosimy o uważne przeczytanie niniejszej instrukcji, po- nieważ zawiera ona ważne informacje dotyczące bezpieczeństwa instalacji, użytkowania oraz konserwacji.
  • Page 376 FORCE W Przyciski bezpośrednie Przyciski bezpośrednie (poz. 8, 9, 10 - wygląd 1) zawsze mają taką samą funkcję. Przyciski nawigacji/menu Przyciski nawigacji/menu (poz. 5, 6, 7, 11, 12, 13 - wygląd 1) służą do przechodzenia pomiędzy różnymi menu na pa- nelu sterowania.
  • Page 377 FORCE W KONSERWACJA Patrz wygląd 59 Tryb TEST Patrz wygląd 56 Tryb TEST Wybór rodzaju gazu Patrz Tryb test kaskadowy Patrz “Informacje serwisowe” on page 387 Informacje serwisowe Patrz “Data interwencji serwisowej” on page 387 Data interwencji serwisowej USTAWIENIA Patrz wygląd 7 Język Jednostka miary Patrz wygląd 8...
  • Page 378 FORCE W Wyłączenie zasobnika (economy) Użytkownik może wyłączyć ogrzewanie / utrzymywanie temperatury w zasobniku. W razie wyłączenia ciepła woda użytkowa nie będzie dostępna. Użytkownik może wyłączyć zasobnik (tryb ECO) poprzez naciśnięcie przycisku eco / comfort (poz. 10 - wygląd 1). W trybie ECO na wyświetlaczu pojawia się symbol .
  • Page 379 FORCE W 1.3 Zapłon i wyłączanie Zapłon kotła Nacisnąć przycisk włączenia/wyłączenia (poz. 14 - wygląd 1). Display v.0X Burner Controller 1 v.0X wygląd 7- Zapłon kotła Po naciśnięciu przycisku kontekstowego 1 można wybrać żądany język. Zatwierdzić wybór przyciskiem „OK”. Po naciśnięciu przycisku kontekstowego 3 można przerwać tryb FH. Jeśli nie zostanie dokonany żaden wybór spośród opisanych powyżej, przejść...
  • Page 380 FORCE W Wejść na ekran przedstawiony na wygląd 9, W tym celu przejść w menu ścieżkę „MENU UŻYTKOWNIKA „Ustawie- nia” „Ustawienie zegara”. Nacisnąć przyciski nawigacji 5 i 7, aby wybrać wartość, a następnie ją zmienić za pomocą przycisków kontekstowych 1 i 2. Potwierdzić przyciskiem OK. Set time : 59 to select...
  • Page 381 FORCE W Na wyświetlaczu pojawia się symbol Lato. Funkcja ogrzewania jest wyłączona, natomiast aktywna pozostaje ewentual- na funkcja wytwarzania ciepłej wody użytkowej (z opcjonalnym zasobnikiem zewnętrznym). Aktywny pozostaje system zabezpieczający przed zamarzaniem. Aby wyłączyć tryb Lato, należy ponownie wcisnąć przycisk (poz.
  • Page 382 FORCE W Regulacja redukcji temperatury c.w.u. (z zainstalowanym opcjonalnym zasobnikiem) Wejść do menu „Temp Regulacja”, aby zmienić temperaturę w zakresie od minimum 10°C do maksimum 65°C. Potwierdzić przyciskiem OK. CH setpoint to confirm wygląd 14 Kocioł jest sprzedawany z nieaktywnym programem czasowym. W związku z tym, w razie zapotrzebowania, to jest wartość...
  • Page 383 FORCE W Programowanie czasowe Programowanie zegara odbywa w tym samym trybie zarówno w odniesieniu do ogrzewania, jak i ciepłej wody użytkowej; oba programy są niezależne. Aby przeprowadzić programowanie Ogrzewania, wejść do menu „Program czasowy. Przejść ścieżką „MENU UŻYTKOWNIKA „OGRZEWANIE” „Program czasowy”. Aby przeprowadzić...
  • Page 384 FORCE W Nacisnąć przycisk nawigacji 7, aby wejść na godzinę zakończenia pierwszego przedziału godzinowego (wygląd 19) i ustawić żądaną wartość za pomocą przycisków kontekstowych 1 i 2. Scheduler Set 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copy to the Next Day...
  • Page 385 FORCE W Scheduler Set 06:00 - 16:00 16:00 - 21:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copy to the Next Day Save & Exit to confirm wygląd 22 Scheduler Set 06:00 - 16:00 16:00 - 21:00 21:00 - 06:00 --:-- - --:-- --:-- - --:--...
  • Page 386 FORCE W Programowanie funkcji zabezpieczenia przed bakteriami legionelli (z zainstalowanym opcjonalnym zasobnikiem) Aby włączyć funkcję zabezpieczenia przed bakteriami legionelli, należy ustawić aktywować parametr P23 w MENU TECHNICZNYM poprzez ustawienie go na ON. Aby zaprogramować tę funkcję, należy wejść do menu „Legionella”. W tym celu przejść ścieżkę „MENU UŻYTKOW- NIKA”...
  • Page 387 FORCE W Funkcja Wakacje Wejść do menu „FUNKCJA WAKACJE”. W tym celu przejść ścieżkę „MENU UŻYTKOWNIKA „FUNKCJA WAKACJE” i ustawić: • Datę rozpoczęcia funkcji Wakacje. • Datę zakończenia funkcji Wakacje. Wyświetlacz może pokazać dwa rodzaje ikon: • - Funkcja Wakacje jest zaprogramowana, lecz nie jest jeszcze aktywna. •...
  • Page 388 FORCE W Wyregulować równoległe przesunięcie krzywych od 20 do 60 °C (wygląd 30) za pomocą parametru „Kompensata 1” i potwierdzić przyciskiem OK. OTC Offset 1 to confirm wygląd 28- Równolegle przesunięcie krzywych Jeśli temperatura otoczenia jest niższa od żądanej wartości, zaleca się ustawienie krzywej wyższego rzędu i na odwrót. Dokonywać...
  • Page 389 FORCE W Regulacje z poziomu zdalnego panelu pokojowego Jeśli do kotła podłączono zdalny panel pokojowy (opcja), powyższe regulacje przeprowadzane są zgodnie z opisem przedstawionym w tabela 1. Tabela 1 Regulację można przeprowadzić zarówno z menu zdalnego panelu pokojowego, jak i panelu Regulacja temperatury c.o.
  • Page 390 FORCE W 2. Instalacja 2.1 Zalecenia ogólne INSTALACJA KOTŁA MUSI BYĆ WYKONYWANA WYŁĄCZNIE PRZEZ WYKWALIFIKOWANY PERSONEL, ZGOD- NIE Z WSZYSTKIMI INSTRUKCJAMI PODANYMI W NINIEJSZEJ INSTRUKCJI TECHNICZNEJ, PRZEPISAMI AK- TUALNEGO PRAWA, ZALECENIAMI NORM KRAJOWYCH I LOKALNYCH ORAZ PRZEPISAMI WŁAŚCIWEGO WYKONAWSTWA. 2.2 Miejsce instalacji Generator powinien być...
  • Page 391 FORCE W Pompa obiegowa wysokiej wydajności (opcja) Ustawienie fabryczne jest odpowiednie dla wszystkich instalacji; jednakże za pomocą przełącznika prędkości (patrz wygląd 32) można ustawić inną strategię działania w zależności od parametrów instalacji. 1 2 3 wygląd 32 Ustawienie Dp-v Ustawienie Dp- c Ustawienie Wysokość...
  • Page 392 FORCE W Charakterystyka wody w układzie Przed przystąpieniem do zainstalowania generatora FORCE W należy odpowiednio wyczyścić instalację (zarówno nową, jak i istniejącą), aby usunąć ewentualne pozostałości po instalacji, rozpuszczalniki, błoto i ogólne zanieczyszc- zenia, które mogą obniżać sprawność zabiegów z użyciem środków ochronnych. Stosować neutralne środki czyszczące, które nie są...
  • Page 393 FORCE W Zawsze sprawdzać stężenie produktu po każdym włączeniu, a także cyklicznie, co najmniej raz w roku. Przeprowadzenie kontroli zlecać wykwalifikowanemu se- rwisantowi z naszej sieci autoryzowanych serwisów technicznych. Tabela 2- Środki chemiczne wskazane jako odpowiednie i dostępne w naszej sieci Autoryzowanych Serwisów Technicznych Produkty alternatywne typu Senti- Opis...
  • Page 394 FORCE W System zabezpieczający przed zamarzaniem, płyny przeciwzamarzaniowe, dodatki i inhibitory Kocioł jest wyposażony w system zabezpieczenia przez zamarzaniem, który włącza kocioł w trybie centralnego ogr- zewania, gdy temperatura wody na zasilaniu instalacji spada poniżej 5°C. Urządzenie nie jest aktywne, jeśli odłączone jest zasilanie elektryczne oraz/lub gazowe.
  • Page 395 FORCE W MENU USER TECHNICIAN wygląd 37 Wpisać kod „4 1 8" za pomocą przycisków kontekstowych 1 i 2. Każdą cyfrę potwierdzić za pomocą przycisku OK. Technician menu Insert code: to select to confirm wygląd 38 Wejść do menu „Parametry”. W tym celu nacisnąć przycisk OK. PARAMETERS MODE to confirm wygląd 39...
  • Page 396 FORCE W Dwa bezpośrednie obwody ogrzewania - Schemat główny wygląd 41 - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 wygląd 42...
  • Page 397 FORCE W Legenda (wygląd 41 - wygląd 42) Termostat pokojowy strefy 1 (bezpośrednia) Strefa 1 (bezpośrednia) Termostat pokojowy strefy 2 (bezpośrednia) Strefa 2 (bezpośrednia) Sonda zewnętrzna Tłoczenie Pompa obiegowa strefy 1 (bezpośrednia) Powrót Pompa obiegowa strefy 2 (bezpośrednia) Urządzenia ochronne wg ISPESL (Jedynie na zamówienie - nie wchodzą w zakres dostawy) Aby zarządzać...
  • Page 398 FORCE W Obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z pompą obiegową - Schemat główny wygląd 44 - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44...
  • Page 399 FORCE W Legenda (wygląd 44 - wygląd 45) Termostat pokojowy strefy 1 (bezpośrednia) Strefa 1 (bezpośrednia) Pompa obiegowa zasobnika Obwód zasobnika Sonda zewnętrzna Tłoczenie Sonda zasobnika Powrót Pompa obiegowa zabezpieczenia przed bakteriami legio- nelli Pompa obiegowa strefy 1 (bezpośrednia) Urządzenia ochronne wg ISPESL (Jedynie na zamówienie - nie wchodzą w zakres dostawy) Aby zarządzać...
  • Page 400 FORCE W Obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z zaworem rozdzielczym (3- żyłowy) - Schemat główny Użyć zaworu rozdzielczego 3-żyłowego: - FAZA OTWARCIA 230V - FAZA ZAMKNIĘCIA 230V - NEUTRALNY o czasach przełączania (od całkowitego zamknięcia do całkowitego otwarcia) nie dłuższych niż 90 sekund. wygląd 46 - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń...
  • Page 401 FORCE W Legenda (wygląd 46 - wygląd 47) Pompa obiegowa ogrzewania Strefa 1 (bezpośrednia) Termostat pokojowy strefy 1 (bezpośrednia) Obwód zasobnika Sonda zewnętrzna Tłoczenie Sonda zasobnika Powrót Zawór 3-drożny (z trzema żyłami) A = FAZA OTWARCIA B = NEUTRALNY C = FAZA ZAMKNIĘCIA Urządzenia ochronne wg ISPESL (Jedynie na zamówienie - nie wchodzą...
  • Page 402 FORCE W Dwa obwody ogrzewania mieszane, obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z pompą obiegową - Schemat główny Karta sterowania strefą FZ4B może zarządzać różnymi typologami instalacji. Poniżej przedstawiono jeden przykład. Użyć zaworu rozdzielczego 3-żyłowego: - FAZA OTWARCIA 230V - FAZA ZAMKNIĘCIA 230V - NEUTRALNY o czasach przełączania (od całkowitego zamknięcia do całkowitego otwarcia) nie dłuższych niż...
  • Page 403 FORCE W - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale. wygląd 50 Legenda Termostat pokojowy strefy 1 (mieszana) Termostat bezpieczeństwa strefy 1 (mieszana) 317a Termostat pokojowy strefy 2 (mieszana) Termostat bezpieczeństwa strefy 2 (mieszana) 317b...
  • Page 404 FORCE W - Parametry Każda instalacja wymaga innego ustawienia parametrów. Przeprowadzić poniższą procedurę. Menu „Parametry - Konfiguracja” Sprawdzić/Zmienić parametr b02 w menu „Parametry - Konfiguracja” na 9. Sprawdzić/Zmienić parametr b08 w menu „Parametry - Konfiguracja” na 1. Sprawdzić/Zmienić parametr b04, b05 i b06 w menu „Parametry - Konfiguracja” odpowiednio do wartości podanych w tabeli *** 'Menu Parametry - Konfiguracja' on page 413 ***.
  • Page 405 FORCE W 2.4 Podłączenie gazu Przed podłączeniem gazu sprawdzić, czy urządzenie jest przystosowane do działania z dostępnym typem paliwa i dokładnie przeczyścić wszystkie rury ga- zowe instalacji, aby usunąć ewentualne pozostałości mogące negatywnie wpłynąć na pracę kotła. Gaz należy podłączyć do właściwego przyłącza (patrz ) zgodnie z obowiązującymi przepisami, za pomocą sztywnej rury metalowej lub giętkiego przewodu o ściance ciągłej ze stali nierdzewnej, wstawiając zawór gazu pomiędzy instalację...
  • Page 406 FORCE W Podłączając zdalne sterowanie czasowe lub wyłącznik czasowy (timer) należy unikać podłączania zasilania tych urządzeń do ich styków przerywających. Ich za- silanie należy wykonać poprzez bezpośrednie podłączenie do sieci lub do baterii, zależnie od typu urządzenia. Sonda zewnętrzna (opcja) Podłączyć...
  • Page 407 FORCE W 2.6 Przewód spalin KOCIOŁ MUSI BYĆ ZAINSTALOWANY W MIEJSCACH, KTÓRE SPEŁNIAJĄ PODSTAWOWE WYMAGANIA WENTYLACJI. W INNYM PRZYPADKU ISTNIEJE NIEBEZPIECZEŃSTWO UDUSZENIA LUB ZATRUCIA. PRZED INSTALACJĄ URZĄDZENIA NALEŻY PRZECZYTAĆ INSTRUKCJĘ IN- STALACJI I KONSERWACJI. NALEŻY RÓWNIEŻ PRZESTRZEGAĆ INSTRUKCJI KONSTRUKCYJNYCH. W PRZYPADKU CIŚNIENIA WEWNĄTRZ RUR SPALINOWYCH POWYŻEJ 200 Pa NALEŻY OBOWIĄZKOWO STOSOWAĆ...
  • Page 408 FORCE W Tabela 4Tabela akcesoriów MODELE FORCE W FORCE W FORCE W FORCE W FORCE W Maksymalna dozwolona wysokość ciśnienia (Pa) RURA 1 m m/ż 11,9 16,0 24,5 RURA 0.5 m m/ż 12,3 KOLANKO 90° Ø80 KOLANKO 45° 19,5 31,5 KOŃCÓWKA RURA 1 m m/ż...
  • Page 409 FORCE W 2.7 Podłączenie spustu kondensatu OSTRZEŻENIA Kocioł jest wyposażony w syfon do spustu kondensatu. Aby przeprowadzić montaż, należy postępować zgodnie z na- stępującymi instrukcjami. 1. Zamocować syfon. 2. Przed podłączeniem przewodu elastycznego do instalacji spustowej, napełnić syfon wodą. 3. Podłączyć przewód elastyczny syfonu do instalacji spustu kondensatu. Przyłącza sieci kanalizacyjnej powinny być...
  • Page 410 (posiadający przewid- ziane przez obowiązującą normę zawodowe kompetencje techniczne) jak np. personel lokalnego serwisu technicznego. FERROLI nie ponosi żadnej odpowiedzialności za szkody majątkowe i/lub uszkodzenia cielesne powstałe na skutek inte- rwencji przy urządzeniu przez osoby bez kwalifikacji i upoważnienia.
  • Page 411 FORCE W wygląd 57- Modele FORCE W 60 i FORCE W 80 wygląd 58- Modele FORCE W 99, FORCE W 120 i FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 412 FORCE W Uruchomienie trybu TEST Wejść na ekran przedstawiony na wygląd 59, W tym celu przejść w menu ścieżkę „MENU UŻYTKOWNIKA Konse- rwacja Tryb TEST Tryb test”. Kocioł włącza się po osiągnięciu maksymalnej mocy ogrzewania (Range Rated) ustawionej zgodnie z opisem w następ- nym rozdziale w sposób stopniowy.
  • Page 413 FORCE W Wykres regulacji obciążenia cieplnego A = kW - B = Parametr karty elektronicznej wygląd 60 MENU SERWISANTA JEDYNIE WYKWALIFIKOWANY PERSONEL MOŻE UZYSKAĆ DOSTĘP DO MENU SERWISOWEGO ORAZ ZMIE- NIAĆ PARAMETRY. Dostęp do Menu Serwisanta jest możliwe dopiero po wpisaniu kodu 4 1 8. Jest ważne przez 15 minut. Menu Parametry - Konfiguracja Dostępnych jest 16 parametrów oznaczonych literą...
  • Page 414 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Parametr Opis Zakres Wentylacja wtórna 0-120 sekund Wstępna wentylacja 1-15 minut pomieszczenia z kotłem Wentylacja następcza 1-15 minut pomieszczenia z kotłem OFF=Wyłączony Czujnik spalin ON (Wł.) ON (Wł.) ON (Wł.) ON (Wł.) ON (Wł.)
  • Page 415 FORCE W FORCE W FORCE W FORCE FORCE W FORCE Parametr Opis Zakres W 99 W 150 Przy B02 = 7 - Niewykorzystane Przy B02 = 8 - Maksymalna nastawa użytkownika wody 40° ÷ 70° 65° 65° 65° 65° 65° użytkowej Przy B02 = 9 - Maksymalna nastawa użytkownika wody 40°...
  • Page 416 FORCE W FORCE W FORCE W FORCE W FORCE W FORCE W Parametr Opis Zakres Brak funkcji P.03 Czas zaworu 3-drożnego 0 ÷ 255 sekund P.04 Timer włączenia* 0 ÷ 255 min. P.05 Timer wyłączenia* 0 ÷ 255 min. P.06 Moc włączenia* 0 ÷...
  • Page 417 FORCE W • Sprawdzić prawidłowość połączeń instalacji elektrycznej i działanie instalacji uziemiającej. • Sprawdzić, czy wartość ciśnienia gazu dla c.o. jest z godna z wymaganą • Sprawdzić, czy nie ma płynów lub materiałów łatwopalnych w bezpośredniej bliskości kotła JEŚLI POWYŻSZE INSTRUKCJE NIE SĄ PRZESTRZEGANE, MOŻE WYSTĄPIĆ...
  • Page 418 FORCE W • Kontrola i czyszczenie systemu kanał-kolektor-komin odprowadzający produkty spalania. • Kontrola i wstępne obciążenie zbiorników wyrównawczych. • Kontrola prawidłowego i stabilnego ciśnienia wody w instalacji. Upewnienie się, że jest ono zgodne z ciśnieniem ro- boczym przewidzianym przez centralkę. Użycie systemów automatycznego napełnienia w celu przywrócenia warunków roboczych powinno zakładać...
  • Page 419 FORCE W Konserwacja nadzwyczajna oraz wymiana komponentów Wymiana elektrody Czyszczenie wymiennika 3.4 Rozwiązywanie problemów cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 420 FORCE W Diagnostyka Kocioł jest wyposażony w zaawansowany system autodiagnostyczny. W razie nieprawidłowości w działaniu kotła na wyświetlaczu pojawi się kod usterki oraz - w przypadku połączenia kaskadowego - numer modułu. • Istnieją usterki, które powodują stałą blokadę. W celu przywrócenia pracy należy nacisnąć przycisk OK i przytrzy- mać...
  • Page 421 FORCE W Usterka Możliwa przyczyna Środki zaradcze usterki Uszkodzony czujnik Awaria czujnika powrotu Okablowanie zwarte Sprawdzić okablowanie lub wymienić czujnik Instalacja elektryczna odłączona Uszkodzony czujnik Awaria czujnika c.w.u. Okablowanie zwarte Sprawdzić okablowanie lub wymienić czujnik Instalacja elektryczna odłączona Uszkodzony czujnik Usterka czujnika spalin Okablowanie zwarte Sprawdzić...
  • Page 422 FORCE W 4. Parametry i dane techniczne Legenda do rysunku cap. 4 "Parametry i dane techniczne" Wlot gazu - Ř 1” Wymiennik z aluminium Zasilanie instalacji - Ř 1” 1/2 Czujnik bezpieczeństwa Powrót z instalacji - Ř 1” 1/2 Złącze spustu kondensatu Zawór bezpieczeństwa Wentylator Pompa obiegowa ogrzewania (niedostarczona...
  • Page 423 FORCE W 4.1 Wymiany i złącza wygląd 62- Widok z przodu wygląd 63- Widok z boku wygląd 64- Widok z góry wygląd 65- Widok od dołu mod. FORCE W 60 i FORCE W 80 wygląd 66- Widok od dołu mod. FORCE W 99 i FORCE W 120 wygląd 67- Widok od dołu mod.
  • Page 424 FORCE W 4.2 Widok ogólny wygląd 68- Widok ogólny mod. FORCE W 60 i FORCE W 80 wygląd 69- Widok ogólny mod. FORCE W 99 i FORCE W 120 wygląd 70- Widok ogólny mod. FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 425 FORCE W 4.3 Obwód hydrauliczny wygląd 71- Obwód hydrauliczny cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 426 FORCE W 4.4 Tabela danych technicznych W kolumnie prawej podane są skróty stosowane na tabliczce znamionowej. Model FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 KODY IDENTYFIKACYJNE PRODUKTÓW 0MDLAAWA 0MDLCAWA 0MDLDAWA 0MDLEAWA 0MDLFAWA KRAJE PRZEZNACZENIA IT ES RO RU PL BG DE GR HR LV UA KATEGORIA GAZU...
  • Page 427 FORCE W 4.5 Tabele ErP cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 428 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 429 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 430 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 431 FORCE W cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 432 FORCE W 4.6 Wykresy Straty ciśnienia wygląd 72- Wykres strat ciśnienia w modelach FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 wygląd 73- Wykres strat ciśnienia w modelach FORCE W 150 Natężenie przepływu - m cod.
  • Page 433 FORCE W 4.7 Schematy elektryczne UWAGA: Przed podłączeniem termostatu pokojowego lub zdalnego panelu pokojowego zdjąć mostek w skr- zynce zaciskowej. wygląd 74- Schemat elektryczny modeli FORCE W 60 oraz FORCE W 80 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 434 FORCE W wygląd 75- Schemat elektryczny modeli FORCE W 99, FORCE W 120 oraz FORCE W 150 cod. 3541Q764 - Rev. 00 - 05/2021...
  • Page 436 Fabbricato in Italia - Fabricado en Italia - Организация, уполномоченная производителем на принятие претензий от потребителя: ИЗАО "ФерролиБел". УНП 690655161. Адрес: улица Заводская, дом 45, город Фаниполь, Дзержинский район, Минская область, Республика Беларусь, 222750. Телефон: +375 (17) 169-79-49, адрес электронной почты: ferroli@ferroli.by.

Ce manuel est également adapté pour:

Force w 60Force w 80Force w 99Force w 120Force w 150