Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 284

Liens rapides

FORCE W
ISTRUZIONE PER L'USO L'INSTALLAZIONE E LA MANUTENZIONE
IT
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
ES
RO
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
EN
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
FR
RU
PL

Publicité

Table des Matières
loading

Sommaire des Matières pour Ferroli FORCE W

  • Page 1 FORCE W ISTRUZIONE PER L’USO L’INSTALLAZIONE E LA MANUTENZIONE INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE INSTRUCTIONS D’UTILISATION, D’INSTALLATION ET D’ENTRETIEN...
  • Page 2 FORCE W • Leggere attentamente le avvertenze contenute in questo li- spetto di quanto sopra può compromettere la sicurezza bretto di istruzioni in quanto forniscono importanti indicazioni dell’apparecchio. riguardanti la sicurezza di installazione, l’uso e la manuten- • Per garantire il buon funzionamento dell’apparecchio è indi- zione.
  • Page 3: Table Des Matières

    FORCE W 1 Istruzioni d’uso ........................4 1.1 Presentazione ............................4 1.2 Pannello comandi........................... 4 1.3 Accensione e spegnimento ........................8 1.4 Regolazioni............................. 9 2 Installazione ........................... 17 2.1 Disposizioni generali ..........................17 2.2 Luogo d’installazione ..........................17 2.3 Collegamenti idraulici ........................... 17 2.4 Collegamento gas ..........................
  • Page 4: Istruzioni D'uso

    1.1 Presentazione Gentile cliente, La ringraziamo di aver scelto FORCE W, una caldaia murale a camera stagna FERROLI di concezione avanzata, tec- nologia d’avanguardia, elevata affidabilità e qualità costruttiva. La preghiamo di leggere attentamente il presente ma- nuale perchè fornisce importanti indicazioni riguardanti la sicurezza di installazione, uso e manutenzione.
  • Page 5 FORCE W Tasti diretti I tasti diretti (part. 8, 9, 10 - fig. 1) hanno sempre la stessa funzione. Tasti navigazione/menù I tasti navigazione/menù (part. 5, 6, 7, 11, 12, 13 - fig. 1) servono per navigare tra i vari menù implementati nel pannello di controllo.
  • Page 6 FORCE W MANUTENZIONE Vedi fig. 73 Modalità Test Vedi fig. 69 Modalità Test Selezione Tipo Gas Modalità Test Cascata Vedi “Informazione Service” a pag. 14 Informazione Service Vedi “Data Intervento Service” a pag. 14 Data Intervento Service IMPOSTAZIONI Vedi fig. 8 Lingua Unità...
  • Page 7 FORCE W Esclusione bollitore (economy) Il riscaldamento/mantenimento in temperatura del bol- litore può essere escluso dall'utente. In caso di esclu- sione, non vi sarà erogazione di acqua calda sanitaria. Il bollitore può essere disattivato dall’utente (modalità ECO) premendo il tasto eco/comfort (part. 10 - fig. 1).
  • Page 8: Accensione E Spegnimento

    FORCE W 1.3 Accensione e spegnimento Accensione caldaia Premere il tasto d’accensione/spegnimento (part 14 - • Scomparsa la scritta FH, la caldaia è pronta per fig. 1). funzionare automaticamente ogni qualvolta vi sia una richiesta al termostato ambiente. Premendo il tasto contestuale 1 è possibile scegliere la lingua desiderata e confermarla attraverso il tasto “OK”.
  • Page 9: Regolazioni

    FORCE W Spegnimento caldaia Dalla schermata principale/Home, premere il tasto contestuale e confermare con il tasto Quando la caldaia viene spenta, la scheda elettronica è ancora alimentata elettricamente. È disabilitato il funzionamento sanitario (con bollitore opzionale installato) e riscaldamento. Rimane attivo il sistema antigelo.
  • Page 10 FORCE W Riduzione della temperatura riscaldamento Accedere al menù “Temp Regolazione Riduzione” CH setpoint reduction per variare la temperatura da un minimo di 0°C ad un massimo di 50°. Confermare con il tasto OK. Questo parametro viene utilizzato solo se è...
  • Page 11 FORCE W Selezionare il giorno (fig. 17) o l’intervallo di giorni da programmare (fig. 18) e confermare con il tasto OK. Scheduler Set Scheduler Set Wednesday Monday Thursday Tuesday Friday Wednesday Saturday Thursday Sunday Friday Monday-Sunday Saturday Monday-Friday Sunday Saturday-Sunday...
  • Page 12 FORCE W Premere il tasto di navigazione 7 ed utilizzare i tasti Scheduler Set contestuali 1 e 2 per impostare la modalità di lavoro durante la prima fascia oraria (fig. 21) 06:00 - 16:00 --:-- - --:-- --:-- - --:--...
  • Page 13 FORCE W Per ripristinare il programma orario ai valori Scheduler Set di fabbrica, premere il tasto contestuale 3 nel menù Programma Orario (fig. 26) e con- Monday fermare con OK. Tuesday Wednesdey Thursday Friday Saturday Sunday Monday-Sunday to confirm fig. 26 I due programmi orari Riscaldamento e Sanitario sono indipendenti anche in caso di Ripristino al valore di fab- brica.
  • Page 14 FORCE W Funzione Vacanze Accedere al menù “FUNZIONE VACANZA” attraverso il percorso “MENÙ UTENTE “FUNZIONE VACANZA” per po- ter impostare: • Data inizio Vacanza. • Data fine Vacanza. Il display può attivare due tipi di icone: • - La funzione Vacanze é programmata ma non ancora attiva.
  • Page 15 FORCE W Regolare lo spostamento parallelo delle curve da 20 a OTC Offset 1 60 °C (fig. 31), attraverso il parametro “Offset1” e confermare con il tasto OK. to confirm fig. 29 - Spostamento parallelo delle curve Se la temperatura ambiente risulta inferiore al valore desiderato si consiglia di impostare una curva di ordine superiore e viceversa.
  • Page 16 FORCE W Regolazioni da cronocomando remoto Se alla caldaia è collegato il Cronocomando Remoto (opzionale), le regolazioni descritte in precedenza ven- gono gestite secondo quanto riportato nella tabella 1. Tabella 1 Regolazione temperatura riscalda- La regolazione può essere eseguita sia dal menù del Cronocomando Remoto sia dal pan- mento nello comandi caldaia.
  • Page 17: Installazione

    FORCE W 2. Installazione 2.1 Disposizioni generali L'INSTALLAZIONE DELLA CALDAIA DEVE ESSERE EFFETTUATA SOLTANTO DA PERSONALE SPECIALIZZATO E DI SICURA QUALIFICAZIONE, OTTEMPERANDO A TUTTE LE ISTRUZIONI RIPORTATE NEL PRESENTE MA- NUALE TECNICO, ALLE DISPOSIZIONI DI LEGGE VIGENTI, ALLE PRESCRIZIONI DELLE NORME NAZIONALI E LOCALI E SECONDO LE REGOLE DELLA BUONA TECNICA.
  • Page 18 FORCE W Circolatore ad alta efficienza (opzionale) L'impostazione di fabbrica é idonea per tutte le instal- lazioni; tuttavia, è possibile impostare, tramite il tasto di selezione (vedi particolare 1 di fig. 33), una strate- gia di funzionamento diversa in funzione delle caratte- ristiche dell'impianto.
  • Page 19 FORCE W - Impostazione Comando esterno La velocità della pompa viene determinata dal segnale esterno proveniente dalla centralina di controllo della caldaia. PWM tipo 1: La velocità della pompa viene regolata in funzione del segnale PWM. In caso di rottura del cavo, la pompa accellera al numero di giri massimo.
  • Page 20 FORCE W Caratteristiche dell’acqua impianto Prima di procedere all'installazione del generatore FORCE W, l'impianto, nuovo o esistente, deve essere opportuna- mente pulito allo scopo di eliminare residui installativi, solventi, fanghi e contaminanti in genere che possano precludere l'efficacia dei trattamenti condizionanti di protezione. Utilizzare prodotti di pulizia neutri non aggressivi verso metalli, gomma e parti in plastica del generatore/impianto.
  • Page 21 FORCE W Verificare sempre la concentrazione di prodotto dopo ogni inserimento e ciclica- mente, almeno una volta all'anno avvalendosi di personale tecnico qualificato qua- le la nostra rete di assistenza tecnica autorizzata. Tabella 2 - Condizionanti chimici dichiarati idonei e disponibili presso la nostra rete di Centri Assi-...
  • Page 22 FORCE W Kit opzionali A richiesta sono disponibili i seguenti kit: cod. 042070X0 - KIT CIRCOLATORE ad ALTA EFFICIENZA - 7m. (A - fig. 34) cod. 042071X0 - KIT CIRCOLATORE ad ALTA EFFICIENZA - 10m. (A - fig. 34) cod. 042072X0 - KIT IDRAULICO Nel Kit 042072X0 sono contenuti: VALVOLA DI NON RITORNO - Femmina 1”1/2 (B - fig.
  • Page 23 FORCE W Esempi circuiti idraulici Negli esempi descritti in seguito potrebbe essere ri- MENU chiesto di verificare/modificare alcuni parametri. Per fare questo è necessario accedere al menù Tec- USER nico. Dalla schermata principale (Home), premere il tasto TECHNICIAN Menù principale (part. 12 - fig. 1).
  • Page 24 FORCE W Due circuiti riscaldamento diretti - Schema di principio fig. 39 - Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo. Legenda (fig. 39 e fig. 40)
  • Page 25 FORCE W - Parametri Ogni impianto necessita di una diversa parametrizzazione. Seguire la procedura d’accesso riportata di seguito. “Menù Tipo Impianto” Modificare parametro P.01 del “Menù Tipo Impianto” a 4. - Funzionalità opzionali Oltre ai collegamenti elettrici della precedente figura (necessari a questa configurazione d’impianto) esistono delle op- zioni che non necessitano di impostazioni.
  • Page 26 FORCE W Un circuito riscaldamento diretto ed un circuito sanitario con circolatore - Schema di principio fig. 42 - Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo.
  • Page 27 FORCE W - Parametri Ogni impianto necessita di una diversa parametrizzazione. Seguire la procedura d’accesso riportata di seguito. “Menù Parametri - Configurazione” Verificare/Modificare parametro b02 del “Menù Parametri Trasparenti” a 8. Verificare/Modificare parametro b08 del “Menù Parametri Trasparenti” a 1.
  • Page 28 FORCE W Un circuito riscaldamento diretto ed un circuito sanitario con valvola deviatrice (a 3 fili) - Schema di principio Utilizzare valvole deviatrici a 3 fili: - FASE APERTURA 230V - FASE CHIUSURA 230V - NEUTRO con tempi di commutazione (da tutto chiuso a tutto aperto) non superiori a 90 secondi.
  • Page 29 FORCE W Per gestire la temperatura scorrevole è necessario acquistare la sonda esterna accessoria cod. 013018X0 In caso di utilizzo di una sonda bollitore (non fornita), è necessario acquistare la sonda NTC accessoria cod. 1KWMA11W (2 mt.) oppure cod. 043005X0 (5 mt.) In caso di utilizzo di un termostato bollitore (non fornito) è...
  • Page 30 FORCE W Due circuiti riscaldamento miscelati, un circuito riscaldamento diretto e un circuito sanitario con circolatore - Schema di principio La scheda controllo zone FZ4B può gestire diverse tipologie d’impianto. Quello riportato è un esempio. Utilizzare valvole deviatrici a 3 fili:...
  • Page 31 FORCE W - Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...
  • Page 32 FORCE W Legenda (fig. 48 e fig. 49) 72a Termostato ambiente 1a zona (miscelata) B = NEUTRO 72b Termostato ambiente 2a zona (miscelata) C = FASE CHIUSURA 72c Termostato ambiente 3a zona (diretta) 317a Termostato di sicurezza 1a zona (miscelata)
  • Page 33: Collegamento Gas

    FORCE W 2.4 Collegamento gas Prima di effettuare l’allacciamento, verificare che l’apparecchio sia predisposto per il funzionamento con il tipo di combustibile disponibile ed effettuare una accurata pulizia di tutte le tubature gas dell’impianto, per rimuovere eventuali residui che po- trebbero compromettere il buon funzionamento della caldaia.
  • Page 34 FORCE W Sonda esterna (optional) Collegare la sonda ai rispettivi morsetti. La massima lunghezza consentita del cavo elettrico di collegamento caldaia – sonda esterna è di 50 m. Può essere usato un comune cavo a 2 conduttori. La sonda esterna va installata preferibil- mente sulla parete Nord, Nord-Ovest o su quella su cui si affaccia la maggioranza del locale principale di soggiorno.
  • Page 35 FORCE W Per il collegamento in cascata NOTA: l’elettronica di caldaia è in grado di gestire fino ad un massimo di 6 moduli. 1. Collegare i moduli come mostrato in fig. 53 (esempio con 3 moduli) fig. 53 - Collegamento in cascata A 1°...
  • Page 36 FORCE W Generatori in cascata: un circuito riscaldamento diretto e un circuito sanitario con circolatore Schema di principio L’elettronica di caldaia è in grado di gestire fino ad un massimo di 6 moduli. L’esempio ne riporta 3. fig. 54 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 37 FORCE W Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo. 300M 300S 9 10 11 12 13 14 15 16 17 18...
  • Page 38 “Per ulteriori schemi di collegamento in cascata, idraulico ed elettrico, vi invitiamo a consultare il sito www.ferroli.com nella sezione dedicata ai prodotti RESIDENZIALE, Caldaie, FORCE W e scaricare alla voce MANUALI i documenti tec- nici che riportano tutte le specifiche di installazione e configurazione: MANUALE PROGETTISTI RISCALDAMENTO PROFESSIONALE (CATALOGO RISCALDAMENTO PROFESSIONALE_89CI3001_00_low.pdf)
  • Page 39: Condotti Fumo

    FORCE W 2.6 Condotti fumo LE CALDAIE DEVONO ESSERE INSTALLATE IN LOCALI CHE RISPONDONO AI REQUISITI DI AEREAZIONE FONDAMENTALI. IN CASO CONTRARIO SUS- SISTE PERICOLO DI ASFISSIA O DI INTOSSICAZIONE. LEGGERE LE ISTRUZIONI DI INSTALLAZIONE E DI MANUTENZIONE PRIMA DI INSTALLARE L’APPARECCHIO.
  • Page 40 TERMINALE Esempi di calcolo FORCE W 60: prevalenza disponibile 77 Pa 5 metri TUBO Ø80 + 3 CURVE Ø80 = (5 x 4,8) + (3 x 10)= 55<77 = OK 8 metri TUBO Ø80 + 6 CURVE Ø80 = (8 x 4,8) + (6 x 10)= 100>77 = NO Condotti fumo Se l'installazione dell'apparecchio è...
  • Page 41: Collegamento Scarico Condensa

    FORCE W È necessario che eventuali tratti orizzontali dello scarico fumi siano mantenuti in leggera pendenza verso la caldaia per evitare che eventuale condensa rifluisca verso l’esterno causando gocciolamento. Prima di procedere con l’installazione, verificare con la tabella 5 che non sia superata la massima lunghezza consentita tenendo conto che ogni curva coassiale dà...
  • Page 42: Servizio E Manutenzione

    Personale Qualificato e di sicura qualificazione (in possesso dei requisiti tecnici professionali previsti dalla normativa vigente) come il personale del Servizio Tecnico Assistenza Clienti di Zona. FERROLI declina ogni responsabilità per danni a cose e/o persone derivanti dalla manomissione dell’apparecchio da parte di persone non qualificate e non autorizzate.
  • Page 43 FORCE W • Per modelli W 60 e W 80 Svitare le viti “B” ed estrarre il gruppo “Venturi/valvola a gas” (fig. 63). Svitare le viti “E” e quindi sostituire l’ugello gas “F” con quello contenuto nel kit di trasformazione posizionandolo all’interno della guarnizione “G”.
  • Page 44 FORCE W fig. 65 fig. 66 Svitare le viti “E” e quindi sostituire l’ugello gas “F” con quello contenuto nel kit di trasformazione posizionandolo all’interno della guarnizione “G”. Rimontare i componenti e verificare le tenute (fig. 68). fig. 67 fig. 68...
  • Page 45 FORCE W • Per tutti i modelli Modificare il parametro relativo al tipo di gas come descritto di seguito. Raggiungere la schermata visualizzata in fig. 69 navigando nel menù seguendo il percorso “MENÙ UTENTE Manutenzione Modalità Test Selezione Tipo Gas”. Premere i tasti contestuali 1 e 2 per scegliere il tipo di gas.
  • Page 46 FORCE W fig. 70 - Regolazione massima modelli W 60 e W 80 fig. 71 - Regolazione minima modelli W 60 e W 80 fig. 72 - Regolazione massima e minima modelli W 99, W 120 e W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 47 FORCE W Attivazione modalità TEST Raggiungere la schermata visualizzata in fig. 73 navigando nel menù seguendo il percorso “MENÙ UTENTE nutenzione Modalità Test Modalità test”. La caldaia si accende raggiungendo il massimo della potenza di riscaldamento (Range Rated), impostata come al pa- ragrafo successivo, in maniera graduale.
  • Page 48 FORCE W MENÙ TECNICO L’ACCESSO AL MENÙ SERVICE E LA MODIFICA DEI PARAMETRI PUÒ ESSERE EFFETTUATA SOLO DA PER- SONALE QUALIFICATO. L’accesso al Menù Tecnico è possibile solo dopo aver digitato il codice 4 1 8. Ed è valido per 15 minuti.
  • Page 49 FORCE W Parametro Descrizione Range W 60 W 80 W 99 W 120 W 150 Tempo attesa riscaldamento 0-10 minuti Post Circolazione riscaldamento 0-255 minuti 0-3 Strategia di funziona- Funzionamento pompa mento Velocità minima pompa modulante 0-100% Velocità partenza pompa modulante 0-100% Velocità...
  • Page 50 FORCE W Menù Parametri – Tipo Impianto Sono disponibili 23 parametri indicati dalla lettera “P.” i quali non sono modificabili da Cronocomando Remoto. Parametro Descrizione Range W 60 W 80 W 99 W 120 W 150 0 = Normale richiesta riscaldamento...
  • Page 51: Messa In Servizio

    FORCE W 3.2 Messa in servizio Verifiche da eseguire alla prima accensione, e dopo tutte le operazioni di manu- tenzione che abbiano comportato la disconnessione dagli impianti o un intervento su organi di sicurezza o parti della caldaia: Prima di accendere la caldaia •...
  • Page 52 FORCE W Controllo periodico Per mantenere nel tempo il corretto funzionamento dell’apparecchio, è necessario far eseguire da personale qualificato un controllo annuale che preveda: • Verifica dello stato dello scambiatore di calore e pulizia con prodotti idonei se sporco o impaccato.
  • Page 53 FORCE W Apertura del pannello frontale Alcuni componenti interni alla caldaia possono raggiungere temperature elevate tali da provocare gravi ustioni.Prima di effettuare qualsiasi operazio- ne, attendere che tali componenti si raffreddino o in alternativa indossare guanti adeguati. Per aprire il mantello della caldaia: 1.
  • Page 54 FORCE W Manutenzione straordinaria e sostituzione componenti Sostituzione elettrodo Pulizia scambiatore cod. 3541V233 - Rev 00 - 06/2022...
  • Page 55: Risoluzione Dei Problemi

    FORCE W 3.4 Risoluzione dei problemi Diagnostica La caldaia è dotata di un avanzato sistema di autodiagnosi. Nel caso di un’anomalia alla caldaia, il display si illumina indicando il codice dell’anomalia e, in caso di collegamento in cascata, il numero del modulo.
  • Page 56 FORCE W Codice Anomalia Possibile causa Soluzione anomalia Sensore danneggiato Anomalia sensore sani- Cablaggio in corto circuito Verificare il cablaggio o sostituire il sensore tario Cablaggio interrotto Sensore danneggiato Anomalia sensore fumi Cablaggio in corto circuito Verificare il cablaggio o sostituire il sensore...
  • Page 57: Caratteristiche E Dati Tecnici

    FORCE W 4. Caratteristiche e dati tecnici Legenda figure cap. 4 Entrata gas - Ø 3/4” Mandata impianto - Ø 1” 1/2 Ritorno impianto - Ø 1” 1/2 Valvola di sicurezza Ventilatore Circolatore riscaldamento (non fornito) Sensore temperatura riscaldamento Sfiato aria automatico...
  • Page 58: Dimensioni E Attacchi

    FORCE W 4.1 Dimensioni e attacchi fig. 76 - Vista frontale fig. 77 - Vista laterale fig. 78 - Vista dall’alto fig. 79 - Vista dal basso cod. 3541V233 - Rev 00 - 06/2022...
  • Page 59: Vista Generale

    FORCE W 4.2 Vista generale fig. 81 - Vista generale mod. FORCE W 99 e FORCE W 120 fig. 80 - Vista generale mod. FORCE W 60 e FORCE W 80 fig. 82 - Vista generale mod. FORCE W 150...
  • Page 60: Circuito Idraulico

    FORCE W 4.3 Circuito idraulico fig. 83 - Circuito idraulico cod. 3541V233 - Rev 00 - 06/2022...
  • Page 61: Tabella Dati Tecnici

    FORCE W 4.4 Tabella dati tecnici Nella colonna a destra viene indicata l’abbreviazione utilizzata nella targhetta dati tecnici. cod. 3541V233 - Rev 00 - 06/2022...
  • Page 62 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 63: Tabelle Erp

    FORCE W 4.5 Tabelle ErP cod. 3541V233 - Rev 00 - 06/2022...
  • Page 64 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 65 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 66 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 67 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 68: Diagrammi

    4.6 Diagrammi Perdita di carico fig. 84 - Diagramma perdita di carico modelli FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 85 - Diagramma perdita di carico modelli FORCE W 150 Portata - m...
  • Page 69: Schemi Elettrici

    FORCE W 4.7 Schemi elettrici La legenda delle figure si trova a pag. 57. ATTENZIONE: Prima di collegare il termostato ambiente o il cronocomando remoto, togliere il ponticello sulla morsettiera. ATTENZIONE: per il collegamento della valvola 3-vie (morsetti 13 - 14 - 15), fare riferimento agli schemi di fig. 86 e fig.
  • Page 70 FORCE W fig. 89 - Schema elettrico modelli FORCE W 60 e FORCE W 80 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 71 FORCE W fig. 90 - Schema elettrico modelli FORCE W 99, FORCE W 120 e FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 72 FORCE W ETICHETTATURA AMBIENTALE IMBALLAGGI ITALIA Ai sensi del decreto legislativo 3 settembre 2020, n. 116 e della decisione 97/129/CE , il materiale che com- facilitarne la raccolta, il riutilizzo, il recupero ed il riciclaggio ove questo sia possibile. nella quale ci sono tutte le indicazioni necessarie.
  • Page 73 C e r t i f i c at o d i G a ra n z i a La presente garanzia convenzionale è valida per gli apparecchi...
  • Page 74 FORCE W • Le rogamos leer atentamente las advertencias conte- originales. En caso contrario, se puede comprometer nidas en este manual de instrucciones, ya que propor- la seguridad del aparato. cionan información importante sobre la instalación, el • Para garantizar el buen funcionamiento del aparato es uso y el mantenimiento.
  • Page 75 FORCE W 1 Instrucciones de uso ......................76 1.1 Presentación ............................76 1.2 Panel de mando ........................... 76 1.3 Encendido y apagado........................... 80 1.4 Regulaciones............................81 2 Instalación ..........................89 2.1 Disposiciones generales ........................89 2.2 Lugar de instalación ..........................89 2.3 Conexiones del agua..........................
  • Page 76: Instrucciones De Uso

    FORCE W es un generador térmico para calefacción de alto rendimiento y muy bajas emisiones, con sistema de pre- mezcla y condensación, alimentado con gas natural (G20), gas líquido (G30-G31) y aire propanado (G230) y equi- pado con un sistema de control con microprocesador.
  • Page 77 FORCE W Teclas directas Las teclas directas ( 8, 9 y 10 - fig. 1) tienen siempre la misma función. Tecla de navegación en menús Las teclas de navegación en menús ( 5, 6, 7, 11, 12 y 13 - fig. 1) permiten recorrer los diversos menús implementados en el panel de control.
  • Page 78 FORCE W MANTENIMIENTO Vea fig. 73 Modo Test Vea fig. 69 Modo Test Selección Tipo Gas Modo Test Cascada Vea “Información Asistencia” on page 86 Información Asistencia Vea “Fecha intervención Asistencia” on page 86 Fecha intervención Asistencia AJUSTES Vea fig. 8...
  • Page 79 FORCE W Exclusión del acumulador (Economy) El calentamiento/mantenimiento en temperatura del acumulador puede ser desactivado por el usuario. En tal caso, no hay suministro de agua caliente sanitaria. Para desactivar el acumulador y establecer el modo ECO, pulse la tecla eco/comfort ( 10 - fig. 1). En 23°C...
  • Page 80: Encendido Y Apagado

    FORCE W 1.3 Encendido y apagado Encendido de la caldera Pulse la tecla de encendido/apagado (14 - fig. 1). Seleccione el idioma con la tecla contextual 1 y confír- melo con la tecla “OK”. Pulse la tecla contextual 3 si desea interrumpir el modo FH.
  • Page 81: Regulaciones

    FORCE W Apagado de la caldera Desde la pantalla principal (Inicio), pulse la tecla con- textual y confirme con la tecla Cuando la caldera se apaga, la tarjeta electrónica per- manece conectada. Se deshabilitan la producción de agua sanitaria (con acumulador opcional instalado) y la calefacción.
  • Page 82 FORCE W Reducción de la temperatura de calefacción Acceda al menú “Temp. Regulación Reducción” Temp Regulación Reducida para regular la temperatura desde un mínimo de 0 °C hasta un máximo de 50 °C. Confirme con la tecla OK. Este parámetro se utiliza solamente si está...
  • Page 83 FORCE W Seleccione el día (fig. 17) o el intervalo de días que desee programar (fig. 18) y confírmelo con la tecla OK. Programa horario Programa horario Miercoles Lunes Jueves Martes Viernes Miercoles Sabado Jueves Domingo Viernes Lunes-Domingo Sabado Lunes-Viernes...
  • Page 84 FORCE W Pulse la tecla de navegación 7 y utilice las teclas con- Programa horario textuales 1 y 2 para seleccionar el modo de funciona- miento durante la primera franja horaria (fig. 21). 06:00 - 16:00 --:-- - --:-- --:-- - --:--...
  • Page 85 FORCE W Para restablecer los valores de fábrica del Programa horario programa horario, pulse la tecla contextual 3 en el menú Programa horario (fig. 26) y Lunes confirme con OK. Martes Miercoles Jueves Viernes Sabado Domingo Lunes-Domingo para confirmar fig. 26 Los dos programas horarios, calefacción y ACS, son independientes también para el restablecimiento de los...
  • Page 86 FORCE W Función Vacaciones Abra el menú "FUNCIÓN VACACIONES" siguiendo la ruta "MENÚ DE USUARIO “FUNCIÓN VACACIONES” para programar: • Fecha de inicio de las vacaciones • Fecha de terminación de las vacaciones En la pantalla pueden aparecer dos tipos de iconos: •...
  • Page 87 FORCE W Regule el desplazamiento paralelo de las curvas de Offset 1 20 a 60 °C (fig. 31) mediante el parámetro “Offset1” y confirme con la tecla OK. para confirmar fig. 29- Desplazamiento paralelo de las curvas Si la temperatura ambiente es inferior al valor deseado, se aconseja seleccionar una curva de orden superior, y vice- versa.
  • Page 88 FORCE W Regulaciones desde el cronomando a distancia Si la caldera tiene conectado el cronomando a distancia (opcional), las regulaciones descritas anteriormente se realizan según se indica en la tabla 1. Tabla 1 Regulación de la temperatura de cale- Esta regulación se puede hacer tanto en el menú del cronomando a distancia como en el facción...
  • Page 89: Instalación

    FORCE W 2. Instalación 2.1 Disposiciones generales LA CALDERA TIENE QUE SER INSTALADA ÚNICAMENTE POR PERSONAL ESPECIALIZADO Y DEBIDAMENTE CUALIFICADO, RESPETANDO TODAS LAS INSTRUCCIONES DEL PRESENTE MANUAL TÉCNICO, LAS LEYES NACIONALES Y LOCALES ASÍ COMO LAS REGLAS DE LA TÉCNICA.
  • Page 90 FORCE W Bombas de circulación de alta eficiencia (opcional) La configuración de fábrica es adecuada para todas las instalaciones. Sin embargo, es posible configurar con la tecla de selección (ver el detalle 1 de fig. 33) una estrategia de funcionamiento distinta en función de las características de la instalación.
  • Page 91 FORCE W - Configuración del mando exterior La velocidad de la bomba está determinada por la señal exterior proveniente de la centralita de control de la caldera. PWM tipo 1: La velocidad de la bomba se ajusta en función de la señal PWM. Si se rompe el cable, la bomba acelera al número máximo de revoluciones.
  • Page 92 Características del agua de la instalación Antes de instalar el generador FORCE W, es necesario limpiar a fondo el sistema, ya sea nuevo o existente, para eli- minar residuos de mecanizado, disolventes, lodos y contaminantes en general que puedan comprometer la eficacia de los tratamientos de protección.
  • Page 93 FORCE W Tabla 2- Acondicionadores químicos declarados idóneos y disponibles en nuestra red de centros de asistencia técnica autorizada. Productos alternativos tipo Senti- Descripción LIFE PLUS/B - MOLY - MOLY K Inhibidor de corrosión a base de molibdeno X100 LIFE DUE Reducción del ruido y antincrustante de mantenimiento...
  • Page 94 FORCE W Kits opcionales A petición, se suministran los siguientes kits: cód. 042070X0 - KIT BOMBA DE CIRCULACIÓN DE ALTA EFICIENCIA - 7 m (A - fig. 34) cód. 042071X0 - KIT BOMBA DE CIRCULACIÓN DE ALTA EFICIENCIA - 10 m (A - fig. 34) cód.
  • Page 95 FORCE W Ejemplos de circuitos hidráulicos En los ejemplos siguientes se indica la necesidad de MENU controlar/modificar algunos parámetros. Para ello, acceda al menú Técnico. USUARIO Desde la pantalla principal (Inicio), pulse la tecla Menú principal ( 12 - fig. 1).
  • Page 96 FORCE W Dos circuitos de calefacción directos - Esquema general fig. 39 - Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente. A continuación, configure la centralita como se describe en el apartado correspondiente.
  • Page 97 FORCE W - Parámetros Cada aparato necesita una parametrización diferente. Proceda como se describe a continuación. Menú "Tipo instalación" Ajuste el parámetro P.01 del menú "Tipo instalación" a 4. - Funciones opcionales Además de las conexiones eléctricas de la figura anterior, necesarias para esta configuración de la instalación, existen opciones que no precisan ningún ajuste.
  • Page 98 FORCE W Un circuito de calefacción directo y un circuito de ACS con bomba de circulación - Esquema general fig. 42 - Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente.
  • Page 99 FORCE W - Parámetros Cada aparato necesita una parametrización diferente. Proceda como se describe a continuación. Menú "Parámetros - Configuración” Controle/ajuste el parámetro b02 del menú "Parámetros modificables" a 8. Controle/ajuste el parámetro b08 del menú "Parámetros modificables" a 1.
  • Page 100 FORCE W Un circuito de calefacción directo y un circuito de ACS con válvula desviadora (de 3 hilos) - Esquema general Utilice válvulas desviadoras de 3 hilos: - FASE DE APERTURA 230 V - FASE DE CIERRE 230 V - NEUTRO con tiempos de conmutación (de todo cerrado a todo abierto) no superiores a 90 s.
  • Page 101 FORCE W Para el control de la temperatura adaptable, es necesario adquirir la sonda exterior accesoria cód. 013018X0 Si se desea utilizar una sonda para el acumulador (no suministrada), es necesario adquirir la sonda NTC acce- soria cód. 1KWMA11W (2 m) o cód. 043005X0 (5 m).
  • Page 102 FORCE W Dos circuitos de calefacción mezclados, un circuito de calefacción directo y un circuito de AS con bomba de circulación - Esquema general La tarjeta de control de zonas FZ4B puede gestionar distintos tipos de instalación. El esquema presente es solo un ejemplo.
  • Page 103 FORCE W - Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente. A continuación, configure la centralita como se describe en el apartado correspondiente. 9 10 11 12 13 14 15 16 17 18...
  • Page 104 FORCE W Leyenda (fig. 48 y fig. 49) 72a Termostato de ambiente 1ª zona (mezclada) B = NEUTRO 72b Termostato de ambiente 2ª zona (mezclada) C = FASE DE CIERRE 72c Termostato de ambiente 3ª zona (directa) 317a Termostato de seguridad 1ª zona (mezclada) 130 Bomba de circulación del acumulador...
  • Page 105: Conexión Del Gas

    FORCE W 2.4 Conexión del gas Antes de efectuar la conexión, controlar que el aparato esté preparado para fun- cionar con el tipo de combustible disponible y limpiar esmeradamente todos los tu- bos del gas para eliminar los residuos, que podrían perjudicar el funcionamiento de la caldera.
  • Page 106 FORCE W Sonda exterior (opcional) Conecte la sonda a los bornes correspondientes. El cable eléctrico utilizado para conectar la sonda exterior a la caldera no debe medir más de 50 m. Se puede usar un cable común de 2 conductores. La sonda exterior tiene que instalarse preferiblemente en una pared orientada al norte o noroeste, o en la pared correspondiente a la parte principal del salón.
  • Page 107 FORCE W Para la conexión en cascada NOTA: el sistema electrónico de la caldera puede controlar hasta seis módulos. 1. Conecte los módulos como se indica en la fig. 53 (ejemplo con 3 módulos). fig. 53 - Conexión en cascada A Primer módulo...
  • Page 108 FORCE W Generadores en cascada: un circuito de calefacción directo y un circuito de ACS con bomba de cir- culación Esquema general El sistema electrónico de la caldera puede controlar hasta seis módulos. En el ejemplo se ilustran tres. fig. 54...
  • Page 109 FORCE W Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente. A continuación, configure la centralita como se describe en el apartado correspondiente. 300M 300S 9 10 11 12 13 14 15 16 17 18...
  • Page 110 "Para más esquemas de conexión en cascada, hidráulica y eléctrica, le invitamos a consultar el sitio web www.ferro- li.com en la sección dedicada a los productos RESIDENCIAL, Calderas, FORCE W y descargar en el apartado MA- NUALES los documentos técnicos que contienen todas las especificaciones de instalación y configuración:...
  • Page 111: Conductos De Humos

    FORCE W 2.6 Conductos de humos LOS LOCALES DONDE SE INSTALEN LAS CALDERAS DEBEN CUMPLIR LOS REQUISITOS DE VENTILACIÓN FUNDAMENTALES. EN CASO CON- TRARIO, EXISTE PELIGRO DE ASFIXIA O INTOXICACIÓN. LEA LAS INSTRUCCIONES DE INSTALACIÓN Y MANTENIMIENTO ANTES DE INSTALAR EL APARATO.
  • Page 112 TERMINAL Ejemplos de cálculo FORCE W 60: presión de impulsión disponible 77 Pa 5 m TUBO Ø80 + 3 CODOS Ø80 = (5 x 4,8) + (3 x 10) = 55 < 77 = CORRECTO 8 m TUBO Ø80 + 6 CODOS Ø80 = (8 x 4,8) + (6 x 10) = 100 > 77 = INCORRECTO Conductos de humos Si el aparato a instalar es de “tipo C13 o C33”...
  • Page 113: Conexión De La Descarga De Condensado

    FORCE W Los tramos horizontales de salida de humos han de mantener una ligera pendiente hacia la caldera para evitar que la eventual condensación fluya al exterior y gotee. Antes de realizar el montaje, verifique con la tabla 5 que no se supere la longitud máxima permitida, considerando que cada codo coaxial provoca la reducción indicada en la tabla.
  • Page 114: Servicio Y Mantenimiento

    Servicio de Asistencia local, y en confor- midad con las normas vigentes. FERROLI declina toda responsabilidad por daños materiales o personales derivados de la manipulación del aparato por personas que no estén debidamente autorizadas.
  • Page 115 FORCE W • Para modelos W 60 y W 80 Desenrosque los tornillos “B” y extraiga el grupo “Venturi/válvula del gas” (fig. 63). Desenrosque los tornillos “E” y sustituya el inyector de gas “F” por el que se incluye en el kit de cambio de gas, introduciéndolo en la junta “G”.
  • Page 116 FORCE W • Para los modelos W 99, W 120 y W 150 Extraiga la centralita de la válvula de gas (fig. 65). Desenrosque los tornillos “C” (fig. 66) que fijan el ventilador y extraiga el grupo (fig. 67). fig. 65 fig.
  • Page 117 FORCE W • Para todos los modelos: Modifique el parámetro correspondiente al tipo de gas como se indica a continuación. Abra la pantalla ilustrada en la fig. 69 con la ruta "MENÚ USUARIO Mantenimiento Modo Test Selección del tipo de gas”. Pulse las teclas contextuales 1 y 2 para elegir el tipo de gas. Confirme con la tecla OK.
  • Page 118 FORCE W fig. 70- Regulación máxima modelos W 60 y W 80 fig. 71- Regulación mínimo modelos W 60 y W 80 fig. 72- Regulación máxima y mínima modelos W 99, W 120 y W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 119 FORCE W Activación del modo TEST Abra la pantalla ilustrada en la fig. 73 con la ruta "MENÚ USUARIO Mantenimiento Modo Test Modo Test”. La caldera se enciende y alcanza gradualmente la potencia máxima de calefacción (Range Rated) ajustada como se describe en el apartado siguiente.
  • Page 120 FORCE W MENÚ TÉCNICO EL ACCESO AL MENÚ SERVICE Y LA MODIFICACIÓN DE LOS PARÁMETROS ESTÁN RESERVADOS AL PER- SONAL AUTORIZADO. El acceso al Menú Técnico exige la introducción del código 4 1 8. Es válido por 15 minutos. Menú Parámetros - Configuración Hay 16 parámetros, indicados con la letra "b", que no se pueden modificar con el cronomando a distancia.
  • Page 121 FORCE W Parámetro Descripción Campo W 60 W 80 W 99 W 120 W 150 Temperatura mínima consigna virtual 20-80 °C Tiempo espera calefacción 0-10 minutos Poscirculación calefacción 0-255 minutos 0-3 Estrategia de funcio- Funcionamiento de la bomba namiento Velocidad mínima bomba modulante...
  • Page 122 FORCE W Menú Parámetros – Tipo Instalación Hay 23 parámetros, indicados con la letra "P.", que no se pueden modificar con el cronomando a distancia. Parámetro Descripción Campo W 60 W 80 W 99 W 120 W 150 0 = Demanda normal de calefacción 1 = Demanda de mando a distancia con habilitación on-off exterior...
  • Page 123: Puesta En Servicio

    FORCE W 3.2 Puesta en servicio Controles que se han de efectuar durante el primer encendido, tras las operacio- nes de mantenimiento que exijan desconectar la caldera y después de cualquier intervención en los dispositivos de seguridad o componentes de la caldera: Antes de encender la caldera •...
  • Page 124: Mantenimiento

    FORCE W 3.3 Mantenimiento ADVERTENCIAS TODAS LAS OPERACIONES DE MANTENIMIENTO Y SUSTITUCIÓN DEBEN SER REALIZADAS POR UN TÉCNICO AUTORIZADO. Antes de efectuar cualquier operación en el interior de la caldera, desconec- te la alimentación eléctrica y cierre la llave de paso del gas. De lo contrario, puede existir peligro de explosión, choque eléctrico, asfixia o intoxicación.
  • Page 125 FORCE W Apertura del panel frontal Algunos componentes internos de la caldera están a temperaturas muy altas y pueden causar quemaduras graves.Antes de hacer cualquier operación, espere a que dichos componentes se enfríen o colóquese guantes aislantes. Para abrir la cubierta de la caldera: 1.
  • Page 126 FORCE W Mantenimiento extraordinario y sustitución de componentes Sustitución del electrodo Limpieza del intercambiador cod. 3541V233 - Rev 00 - 06/2022...
  • Page 127: Solución De Problemas

    FORCE W 3.4 Solución de problemas Diagnóstico La caldera está dotada de un avanzado sistema de autodiagnóstico. Si se presenta una anomalía en la caldera, la pan- talla se enciende indicando el código de anomalía y, si se trata de una conexión en cascada, el número de módulo.
  • Page 128 FORCE W Código Anomalía Causa posible Solución anomalía Sensor averiado Anomalía del sensor de Cableado en cortocircuito Controlar el cableado o sustituir el sensor retorno Cableado interrumpido Sensor averiado Anomalía del sensor de Cableado en cortocircuito Controlar el cableado o sustituir el sensor...
  • Page 129: Características Y Datos Técnicos

    FORCE W 4. Características y datos técnicos Leyenda de las figuras cap. 4 Entrada de gas - Ø 3/4" Ida a calefacción - Ø 1” 1/2 Retorno de calefacción - Ø 1” 1/2 Válvula de seguridad Ventilador Bomba de la calefacción (no suministrada) Sensor temperatura calefacción...
  • Page 130: Medidas Y Conexiones

    FORCE W 4.1 Medidas y conexiones fig. 76- Vista frontal fig. 77- Vista lateral fig. 78- Vista superior fig. 79- Vista inferior cod. 3541V233 - Rev 00 - 06/2022...
  • Page 131: Vista General

    FORCE W 4.2 Vista general fig. 81- Vista general mods. FORCE W 99 y FORCE W 120 fig. 80- Vista general mods. FORCE W 60 y FORCE W 80 fig. 82- Vista general mod. FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 132: Circuito Hidráulico

    FORCE W 4.3 Circuito hidráulico fig. 83- Circuito hidráulico cod. 3541V233 - Rev 00 - 06/2022...
  • Page 133: Tabla De Datos Técnicos

    FORCE W 4.4 Tabla de datos técnicos En la columna derecha se indica la abreviatura utilizada en la placa de datos técnicos. cod. 3541V233 - Rev 00 - 06/2022...
  • Page 134 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 135: Tablas Erp

    FORCE W 4.5 Tablas ErP cod. 3541V233 - Rev 00 - 06/2022...
  • Page 136 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 137 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 138 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 139 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 140: Diagramas

    4.6 Diagramas Pérdida de carga fig. 84- Diagrama de pérdida de carga modelos FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 85- Diagrama de pérdida de carga modelos FORCE W 150 Caudal - m...
  • Page 141: Esquemas Eléctricos

    FORCE W 4.7 Esquemas eléctricos La leyenda de las figuras está en page 129. ATENCIÓN: Antes de conectar el termostato ambiente o el cronomando a distancia, quite el puente de la caja de conexiones. ATENCIÓN: para conectar la válvula de tres vías (bornes 13 - 14 - 15), véanse los esquemas de fig. 86 y fig. 87.
  • Page 142 FORCE W fig. 89- Esquema eléctrico modelos FORCE W 60 y FORCE W 80 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 143 FORCE W fig. 90- Esquema eléctrico modelos FORCE W 99, FORCE W 120 y FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 144 El período de garantía de 3 años indicado en dicho R.D. comenzará a partir de la fecha de instalación, o en su defecto, a partir de la fecha de compra. desde la entrega no existían cuando el bien se entregó. Transporte no efectuado a cargo de la empresa (que deberán ser reclamados directamente al transportista).
  • Page 145 FORCE W • Citiţi cu atenţie avertizările din acest manual de in- piese de schimb originale. Nerespectarea celor menţio- strucţiuni întrucât oferă indicaţii importante referitoare la nate mai sus poate compromite siguranţa aparatului. siguranţa de instalare, utilizare şi întreţinere. • Pentru a garanta buna funcţionare a aparatului este indi- •...
  • Page 146 FORCE W 1 Instrucţiuni de utilizare......................147 1.1 Prezentare ............................147 1.2 Panoul de comandă ........................... 147 1.3 Pornirea şi oprirea ..........................151 1.4 Reglările ............................. 152 2 Instalarea ..........................160 2.1 Dispoziţii generale ..........................160 2.2 Locul de instalare ..........................160 2.3 Racordurile hidraulice.........................
  • Page 147: Instrucţiuni De Utilizare

    1.1 Prezentare Stimate Client, Vă mulţumim că aţi ales FORCE W, o centrală murală cu cameră etanşă FERROLI de concepţie avansată, tehnologie de avangardă, nivel ridicat de fiabilitate şi calitate constructivă. Vă rugăm să citiţi cu atenţie acest manual întrucât oferă...
  • Page 148 FORCE W Tastele directe Tastele directe (det. 8, 9, 10 - fig. 1) au întotdeauna aceeaşi funcţie. Tastele navigaţie/meniu Tastele navigaţie/meniu (det. 5, 6, 7, 11, 12, 13 - fig. 1) ajută la navigarea printre diferitele meniuri setate pe panoul de control.
  • Page 149 FORCE W ÎNTREŢINEREA Vezi fig. 73 Modul Test Selectarea tipului de Vezi fig. 69 Modul Test Modul Test Cascadă Vezi “Informaţii Service” on page 157 Informaţii Service Vezi “Dată intervenţie service” on page 157 Dată intervenţie service SETĂRI Vezi fig. 8 Limbă...
  • Page 150 FORCE W Excludere boiler (economy) Încălzirea/menţinerea temperaturii boilerului poate fi exclusă de către utilizator. În caz de excludere, nu se va produce apă caldă menajeră. Boilerul poate fi de- zactivat de către utilizator (modul ECO) apăsând pe tasta eco/comfort (det. 10 - fig. 1). În modul ECO, pe 23°C...
  • Page 151: Pornirea Şi Oprirea

    FORCE W 1.3 Pornirea şi oprirea Pornirea centralei Apăsaţi pe tasta de aprindere/stingere (det. 14 - fig. 1). Apăsând pe tasta contextuală 1 puteţi alege limba do- rită şi o puteţi confirma cu ajutorul tastei „OK”. Apăsând pe tasta contextuală 3 puteţi întrerupe modul Dacă...
  • Page 152: Reglările

    FORCE W Oprirea centralei De pe ecranul principal/Home, apăsaţi tasta contex- tuală şi confirmaţi cu tasta Când centrala este oprită, cartela electronică mai este încă alimentată cu energie electrică. E dezactivată funcţionarea circuitului de apă caldă menajeră (cu boiler opţional instalat) şi a circuitului de încălzire.
  • Page 153 FORCE W Reducerea temperaturii de încălzire Accesaţi meniul „Temp. de reglare reducere” pentru CH setpoint reduction a modifica temperatura de la un minim de 0°C la un maxim de 50°. Confirmaţi cu tasta OK. Acest parametru este utilizat numai dacă...
  • Page 154 FORCE W Selectaţi ziua (fig. 17) sau intervalul de zile care trebuie programate (fig. 18) şi confirmaţi cu tasta OK. Scheduler Set Scheduler Set Monday Wednesday Thursday Tuesday Friday Wednesday Saturday Thursday Sunday Friday Monday-Sunday Saturday Monday-Friday Sunday Saturday-Sunday Monday-Sunday...
  • Page 155 FORCE W Apăsaţi tasta de navigaţie 7 şi utilizaţi tastele contex- Scheduler Set tuale 1 şi 2 pentru a seta modul de funcţionare în tim- pul primului interval orar (fig. 21) 06:00 - 16:00 --:-- - --:-- --:-- - --:--...
  • Page 156 FORCE W Pentru a readuce programarea orarului la Scheduler Set valorile din fabricaţie, apăsaţi tasta contex- tuală 3 din meniul Scheduler set (fig. 26) şi Monday confirmaţi cu OK. Tuesday Wednesdey Thursday Friday Saturday Sunday Monday-Sunday to confirm fig. 26 Cele două...
  • Page 157 FORCE W Funcţia Vacanţă Accesaţi meniul „FUNCŢIA VACANŢĂ” urmând calea „MENIU USER „FUNCŢIA VACANŢĂ” pentru a putea seta: • Data de începere a vacanţei. • Data de terminare a vacanţei. Pe afişaj se pot activa două tipuri de pictograme: •...
  • Page 158 FORCE W Reglaţi deplasarea paralelă a curbelor de la 20 la OTC Offset 1 60°C (fig. 31), cu ajutorul parametrului „Offset1”, şi confirmaţi cu tasta OK. to confirm fig. 29- Deplasarea paralelă a curbelor Dacă temperatura ambiantă e mai mică faţă de valoarea dorită, se recomandă să selectaţi o curbă de ordin superior şi invers.
  • Page 159 FORCE W Reglările de la cronocomanda la distanţă Dacă la centrală este conectată Cronocomanda la distanţă (opţional), reglările de mai sus trebuie efectuate conform indicaţiilor din tabel 1. Tabel 1 Reglarea temperaturii în circuitul de Reglarea poate fi efectuată fie din meniul Cronocomenzii la distanţă, fie de la panoul de încălzire...
  • Page 160: Instalarea

    FORCE W 2. Instalarea 2.1 Dispoziţii generale INSTALAREA CENTRALEI TREBUIE EFECTUATĂ NUMAI DE PERSONAL SPECIALIZAT ŞI CU CALIFICARE RE- CUNOSCUTĂ, RESPECTÂNDU-SE TOATE INSTRUCŢIUNILE MENŢIONATE ÎN PREZENTUL MANUAL TEHNIC, DISPOZIŢIILE LEGALE ÎN VIGOARE, CERINŢELE NORMELOR NAŢIONALE ŞI LOCALE ŞI CONFORM REGULI- LOR DE BUNĂ...
  • Page 161 FORCE W Pompă de circulaie cu eficienă ridicată (opional) Setarea din fabricaie este adecvată pentru toate tipu- rile de instalare; cu toate acestea, este posibil să se seteze, cu ajutorul tastei de selectare (vezi detaliul 1 din fig. 33), o strategie de funcionare diferită, în funcie de caracteristicile instalaiei.
  • Page 162 FORCE W - Setarea Comenzii externe Viteza pompei este determinată de semnalul extern provenit de la unitatea de control a centralei. PWM de tipul 1: Viteza pompei este reglată în funcie de semnalul PWM. În cazul în care cablul se rupe, pompa acce- lerează...
  • Page 163 FORCE W Caracteristicile apei din instalaţie Înainte de a începe instalarea generatorului FORCE W, instalaţia, nouă sau existentă, trebuie să fie curăţată corespun- zător, pentru a elimina reziduurile de la instalare, solvenţii, nămolurile şi contaminanţii în general care ar putea reduce eficienţa tratamentelor cu substanţe chimice de protecţie.
  • Page 164 FORCE W Tabel 2- Produse chimice de tratare declarate adecvate şi disponibile în reţeaua noastră de Centre de Asistenţă Tehnică Autorizată Descriere Produse alternative de tip Sentinel LIFE PLUS/B - MOLY - MOLY K Inhibitor de coroziune pe bază de molibden...
  • Page 165 FORCE W Kituri opţionale La cerere sunt disponibile următoarele kituri: cod 042070X0 - KIT POMPĂ DE CIRCULAŢIE cu EFICIENŢĂ RIDICATĂ - 7 m. (A - fig. 34) cod 042071X0 - KIT POMPĂ DE CIRCULAŢIE cu EFICIENŢĂ RIDICATĂ - 10 m. (A - fig. 34) cod 042072X0 - KIT HIDRAULIC În Kit 042072X0 se află:...
  • Page 166 FORCE W Exemple circuite hidraulice În exemplele descrise mai jos poate fi necesar să se MENU verifice/modifice unii parametri. Pentru a face acest lucru este necesar să se acceseze USER meniul Technician. De pe ecranul principal (Home), apăsaţi tasta Meniu principal (det.
  • Page 167 FORCE W Două circuite de încălzire directe - Schemă de principiu fig. 39 - Conexiuni electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică. După aceea, treceţi la configurarea unităţii de comandă, după cum se arată în paragraful respectiv.
  • Page 168 FORCE W - Parametri Fiecare instalaţie necesită o configurare diferită a parametrilor. Urmaţi procedura de acces indicată mai jos. „System Type Menu” Modificaţi parametrul P.01 din „System Type Menu” la 4. - Funcţii opţionale Pe lângă conexiunile electrice din figura anterioară (necesare pentru această configuraţie a instalaţiei) există şi opţiuni care nu necesită...
  • Page 169 FORCE W Un circuit de încălzire direct şi un circuit de apă menajeră cu pompă de circulaţie - Schemă de principiu fig. 42 - Conexiuni electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică.
  • Page 170 FORCE W - Parametri Fiecare instalaţie necesită o configurare diferită a parametrilor. Urmaţi procedura de acces indicată mai jos. „Configuration - Parameters Menu” Verificaţi/Modificaţi parametrul b02 din „Meniul Parametri Transparenţi” la 8. Verificaţi/Modificaţi parametrul b08 din „Meniul Parametri Transparenţi” la 1.
  • Page 171 FORCE W Un circuit de încălzire direct şi un circuit de apă menajeră cu valvă deviatoare (cu 3 fire) - Schemă de principiu Utilizaţi valve deviatoare cu 3 fire: - FAZA DE DESCHIDERE 230 V - FAZA DE ÎNCHIDERE 230 V = NEUTRU cu timpi de comutare (de la complet închis la complet deschis) nu mai mari de 90 secunde.
  • Page 172 FORCE W Pentru a controla temperatura variabilă trebuie să achiziţionaţi sonda externă accesorie, cod 013018X0 În cazul utilizării unei sonde pentru boiler (nu este furnizată), este necesar să achiziţionaţi sonda NTC acceso- rie, cod 1KWMA11W (2 mt.) sau cod 043005X0 (5 mt.) În cazul utilizării unui termostat pentru boiler (nu este furnizat), este necesar să...
  • Page 173 FORCE W Două circuite de încălzire mixte, un circuit de încălzire direct şi un circuit de apă menajeră cu pompă de circulaţie - Schemă de principiu Cartela pentru controlul pe zone FZ4B poate controla diferite tipuri de instalaţii. Aici este prezentat un exemplu.
  • Page 174 FORCE W - Conexiuni electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică. După aceea, treceţi la configurarea unităţii de comandă, după cum se arată în paragraful respectiv. 9 10 11 12 13 14 15 16 17 18...
  • Page 175 FORCE W Legendă (fig. 48 şi fig. 49) 72a Termostat de cameră zona 1 (mixtă) C = FAZA DE ÎNCHIDERE 72b Termostat de cameră zona a 2-a (mixtă) 317a Termostat de siguranţă zona 1 (mixtă) 72c Termostat de cameră zona a 3-a (directă) 317b Termostat de siguranţă...
  • Page 176: Racordarea La Gaz

    FORCE W 2.4 Racordarea la gaz Înainte de efectuarea racordării, verificaţi ca aparatul să fie proiectat pentru funcţionarea cu tipul de combustibil disponibil şi efectuaţi o curăţare corectă a tu- turor ţevilor de gaz ale instalaţiei, pentru a îndepărta eventualele reziduuri care ar putea compromite buna funcţionare a centralei.
  • Page 177 FORCE W Sondă externă (opţională) Conectaţi sonda la bornele corespunzătoare Lungimea maximă permisă a cablului electric de conectare centrală - son- dă externă este de 50 m. Se poate utiliza un cablu normal cu 2 conductori. Sonda externă trebuie instalată de preferat pe peretele dinspre nord, nord-vest, sau pe cel pe care se află...
  • Page 178 FORCE W Pentru montarea în sistem cascadă NOTĂ: cartela electronică a centralei poate gestiona maximum 6 module. 1. Conectaţi modulele aşa cum se arată în fig. 53 (exemplu cu 3 module) fig. 53- Conectare în cascadă A Primul modul C Al 3-lea modul B Al 2-lea modul 2.
  • Page 179 FORCE W Generatoare conectate în cascadă: un circuit de încălzire direct şi un circuit de apă menajeră cu pompă de circulaţie Schemă de principiu Cartela electronică a centralei poate gestiona maximum 6 module. În acest exemplu sunt prezentate 3. fig. 54...
  • Page 180 FORCE W Conexiunile electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică. După aceea, treceţi la configurarea unităţii de comandă, după cum se arată în paragraful respectiv. 300M 300S 9 10 11 12 13 14 15 16 17 18...
  • Page 181 „Pentru mai multe diagrame de conectare în cascadă, hidraulică i electrică, vă invităm să consultai site-ul www.ferro- li.com în seciunea dedicată produselor RESIDENZIALE (Casnice), Caldaie (Centrale), FORCE W şi să descărcaţi, de sub elementul MANUALI (Manuale), documentele tehnice care conin toate specificaiile de instalare i de configurare: MANUAL PENTRU PROIECTANII DE ÎNCĂLZIRE PROFESIONALĂ...
  • Page 182: Conductele Pentru Gaze Arse

    FORCE W 2.6 Conductele pentru gaze arse CENTRALELE TREBUIE SĂ FIE INSTALATE ÎN ÎNCĂPERI CARE CORE- SPUND CERINŢELOR DE VENTILAŢIE FUNDAMENTALE. ÎN CAZ CONTRAR EXISTĂ PERICOLUL DE ASFIXIE SAU DE INTOXICARE. CITIŢI INSTRUCŢIUNILE DE INSTALARE ŞI DE ÎNTREŢINERE ÎNAINTE DE A INSTALA APARATUL.
  • Page 183 TERMINAL Exemple de calcul FORCE W 60: sarcină hidraulică disponibilă 77 Pa 5 metri TUB Ø80 + 3 COTURI Ø80 = (5 x 4,8) + (3 x 10)= 55<77 = OK 8 metri TUB Ø80 + 6 COTURI Ø80 = (8 x 4,8) + (6 x 10)= 100>77 = NO Conductele pentru gaze arse Dacă...
  • Page 184: Racordarea Evacuării Condensului

    FORCE W Este necesar ca eventualele porţiuni orizontale ale conductelor de evacuare a gazelor arse să aibă o uşoară înclinare către centrală, pentru a evita ca eventualul condens să se scurgă spre exterior şi să picure. Înainte de a trece la instalare, verificaţi cu ajutorul tabel 5 să nu se depăşească lungimea maximă permisă, ţinând cont de faptul că...
  • Page 185: Exploatarea Şi Întreţinerea

    Personal Calificat şi cu o calificare atestată (în posesia cerinţelor tehnice profesionale prevăzute de normele în vigoare), ca, de ex., personalul de la Serviciul Tehnic de Asistenţă Clienţi din zonă. FERROLI îşi declină orice responsabilitate pentru pagubele produse bunurilor şi/sau persoanelor ca urmare a intervenţiilor efectuate asupra aparatului de persoane necalificate şi neautorizate.
  • Page 186 FORCE W • Pentru modelele W 60 şi W 80 Deşurubaţi şuruburile „B” şi scoateţi ansamblul “Venturi/valvă de gaz” (fig. 63). Deşurubaţi şuruburile „E” şi apoi înlocuiţi duza de gaz „F” cu cea aflată în kitul de transformare, poziţionând-o în interiorul garniturii „G”.
  • Page 187 FORCE W • Pentru Modelele W 99, W 120 şi W 150 Scoateţi unitatea de comandă din valva de gaz (fig. 65). Deşurubaţi şuruburile „C” (fig. 66) care fixează ventilatorul şi scoateţi ansamblul (fig. 67). fig. 65 fig. 66 Deşurubaţi şuruburile „E” şi apoi înlocuiţi duza de gaz „F” cu cea aflată în kitul de transformare, poziţionând-o în interiorul garniturii „G”.
  • Page 188 FORCE W • Pentru toate modelele Modificaţi parametrul referitor la tipul de gaz, aşa cum se arată în continuare. Accesaţi ecranul prezentat în fig. 69 navigând în meniu, urmând calea „MENŮ UTENTE” (MENIU UTILIZATOR) Manutenzione (Întreţinere) Modalitŕ Test (Modul Test) Selezione Tipo Gas (Selectarea tipului de gaz)”.
  • Page 189 FORCE W fig. 70- Reglarea maximă la modelele W 60 i W 80 fig. 71- Reglarea minimă la modelele W 60 i W 80 fig. 72- Reglarea maximă i minimă la modelele W 99, W 120 i W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 190 FORCE W Activarea modului TEST Duceţi-vă la ecranul prezentat în fig. 73 navigând în meniu, urmând calea „MENIU USER Întreţinerea Modul Test Installer Test Mode”. Centrala se aprinde, atingând puterea maximă de încălzire (Range Rated), reglată conform paragrafului următor, în mod treptat.
  • Page 191 FORCE W MENIUL TECHNICIAN ACCESUL LA MENIUL SERVICE ŞI MODIFICAREA PARAMETRILOR POT FI EFECTUATE NUMAI DE PERSO- NAL CALIFICAT. Accesul la Meniul Technician este posibil numai după ce aţi introdus codul 4 1 8. Şi este valabil timp de 15 minute.
  • Page 192 FORCE W Parametru Descriere Interval W 60 W 80 W 99 W 120 W 150 Temperatură minimă setpoint virtual 20-80°C Interval aşteptare încălzire 0-10 minute Post-circulaţie încălzire 0-255 minute Funcţionare pompă 0-3 Strategie de funcţionare Viteză minimă pompă modulantă 0-100% Viteză...
  • Page 193 FORCE W Meniul Parametri - Tipul instalaţiei Sunt disponibili 23 parametri indicaţi cu litera „P.”, care nu pot fi modificaţi de la Cronocomanda la distanţă. Parametru Descriere Interval W 60 W 80 W 99 W 120 W 150 0 = Cerere normală de încălzire 1 = Cerere de la comanda la distanţă, cu...
  • Page 194: Punerea În Funcţiune

    FORCE W 3.2 Punerea în funcţiune Verificări care trebuie efectuate la prima pornire şi după toate operaţiile de în- treţinere care au impus deconectarea de la instalaţii sau o intervenţie la dispoziti- vele de siguranţă sau la părţi ale centralei: Înainte de pornirea centralei...
  • Page 195: Întreţinerea

    FORCE W 3.3 Întreţinerea AVERTIZĂRI TOATE OPERAţIILE DE ÎNTREţINERE şI DE ÎNLOCUIRE TREBUIE EFECTUA- TE DE PERSONAL CALIFICAT şI CU O CALIFICARE ATESTATĂ. Înainte de efectuarea oricărei operaţiuni în interiorul centralei, întrerupeţi ali- mentarea cu energie electrică şi închideţi robinetul de gaz din amonte. În caz contrar poate să...
  • Page 196 FORCE W Deschiderea panoului frontal Unele componente interne ale centralei pot atinge temperaturi ridicate, care pot provoca arsuri grave.Înainte de a efectua orice operaţie, aşteptaţi ca ace- ste componente să se răcească sau, ca alternativă, purtaţi mănuşi adecvate. Pentru a deschide carcasa centralei: 1.
  • Page 197 FORCE W Întreţinerea extraordinară şi înlocuirea componentelor Înlocuirea electrodului Curăţarea schimbătorului de căldură cod. 3541V233 - Rev 00 - 06/2022...
  • Page 198: Rezolvarea Problemelor

    FORCE W 3.4 Rezolvarea problemelor Diagnosticarea Centrala este dotată cu un sistem avansat de autodiagnosticare. În cazul apariţiei unei anomalii la centrală, afişajul se aprinde, indicând codul anomaliei şi, în cazul conectării în cascadă, numărul modulului. • Există anomalii care cauzează blocări permanente, care pot fi resetate apăsând pe tasta OK timp de o secundă sau cu ajutorul tastei RESET de pe cronocomanda la distanţă...
  • Page 199 FORCE W Anomalie Cauză posibilă Soluţie anomalie Senzor defect Anomalie senzor gaze Cablaj în scurtcircuit Verificaţi cablajul sau înlocuiţi senzorul arse Cablaj întrerupt Senzor defect Anomalie senzor de încăl- Cablaj în scurtcircuit Verificaţi cablajul sau înlocuiţi senzorul zire 2 (Siguranţă) Cablaj întrerupt...
  • Page 200: Caracteristici Şi Date Tehnice

    FORCE W 4. Caracteristici şi date tehnice Legendă figuri cap. 4 "Caracteristici şi date tehnice" Intrare gaz - Ø 3/4” Tur instalaţie - Ø 1” 1/2 Retur instalaţie - Ø 1” 1/2 Supapă de siguranţă Ventilator Pompă de circulaţie încălzire (nu este furnizată) Senzor temperatură...
  • Page 201: Dimensiuni Şi Racorduri

    FORCE W 4.1 Dimensiuni şi racorduri fig. 76- Vedere frontală fig. 77- Vedere laterală fig. 78- Vedere de sus fig. 79- Vedere de jos cod. 3541V233 - Rev 00 - 06/2022...
  • Page 202: Vedere Generală

    FORCE W 4.2 Vedere generală fig. 81- Vedere generală mod. FORCE W 99 şi FORCE W 120 fig. 80- Vedere generală mod. FORCE W 60 şi FORCE W 80 fig. 82- Vedere generală mod. FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 203: Circuitul Hidraulic

    FORCE W 4.3 Circuitul hidraulic fig. 83- Circuitul hidraulic cod. 3541V233 - Rev 00 - 06/2022...
  • Page 204: Tabel Cu Datele Tehnice

    FORCE W 4.4 Tabel cu datele tehnice În coloana din dreapta este indicată abrevierea utilizată pe plăcuţa cu datele tehnice. cod. 3541V233 - Rev 00 - 06/2022...
  • Page 205 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 206: Tabele Erp

    FORCE W 4.5 Tabele ErP cod. 3541V233 - Rev 00 - 06/2022...
  • Page 207 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 208 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 209 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 210 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 211: Diagrame

    4.6 Diagrame Pierdere de sarcină fig. 84- Diagramă pierderi de sarcină modelele FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 85- Diagramă pierderi de sarcină modelele FORCE W 150 Debit - m...
  • Page 212: Scheme Electrice

    FORCE W 4.7 Scheme electrice Legenda figurilor se găseşte la page 200. ATENŢIE: Înainte de a racorda termostatul de cameră sau cronocomanda la distanţă, scoateţi puntea de pe pa- noul de borne. ATENŢIE: pentru racordarea valvei cu 3 căi (bornele 13 - 14 - 15), consultaţi schemele din fig. 86 şi fig. 87.
  • Page 213 FORCE W fig. 89- Schemă electrică modelele FORCE W 60 şi FORCE W 80 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 214 FORCE W fig. 90- Schemă electrică modelele FORCE W 99, FORCE W 120 şi FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 215 FORCE W • Read the warnings in this instruction booklet • Periodic maintenance performed by qualified carefully since they provide important informa- personnel is essential in order to ensure proper tion on safe installation, use and maintenance. operation of the unit.
  • Page 216 FORCE W 1 Operating instructions ......................217 1.1 Introduction............................217 1.2 Control panel ............................217 1.3 Lighting and shutdown ........................221 1.4 Adjustments............................222 2 Installation ..........................230 2.1 General Instructions ........................... 230 2.2 Place of installation ..........................230 2.3 Plumbing connections ........................230 2.4 Gas connection ..........................
  • Page 217: Thursday 9 Jan. 2014 00:15:60

    Please read this manual carefully, as it provides important information on safe installation, use and maintenance. FORCE W is a high-efficiency, low emissions, premix condensing heat generator, running on Natural Gas (G20), Li- quefied Gas (G30-G31) and Propane Air (G230), equipped with a microprocessor control system.
  • Page 218: Fig. 2

    FORCE W Direct buttons The direct buttons (details 8, 9, 10 - fig. 1) always have the same function. Menu/navigation buttons The menu/navigation buttons (details 5, 6, 7, 11, 12, 13 - fig. 1) are used to navigate among the various menus imple- mented in the control panel.
  • Page 219 FORCE W MAINTENANCE See fig. 73 Test Mode See fig. 69 Test Mode Gas Type Selection Cascade Test Mode See “Service Information” on page 227 Service Information See “Service Intervention Date” on page 227 Service Intervention Date SETTINGS See fig. 8...
  • Page 220: Thursday 9 Jan. 2014 11:30:43

    FORCE W Exclude hot water tank (economy) Hot water tank temperature maintaining/heating can be excluded by the user. If excluded, domestic hot water will not be delivered. The hot water tank can be deactivated by the user (ECO mode) by pressing the eco/comfort button (detail 10 - fig.
  • Page 221: Lighting And Shutdown

    FORCE W 1.3 Lighting and shutdown Boiler lighting Press the On/Off button (detail 14 - fig. 1). By pressing contextual button 1 it is possible to choo- se the desired language and confirm it with the “OK” button. By pressing contextual button 3 it is possible to inte- rrupt the FH mode.
  • Page 222: Thursday 9 Jan. 2014 00:15:60

    FORCE W Boiler shutdown From the main screen/Home, press the contextual bu- tton and confirm with the button When the boiler is turned off, the PCB is still powered. Domestic hot water (with optional hot water tank insta- lled) and heating operation are disabled. The frost pro- tection system remains on.
  • Page 223 FORCE W Heating temperature reduction Access the “Reduction Adjustment Temp” menu to CH setpoint reduction vary the temperature from a minimum of 0°C to a maximum of 50°. Confirm with the OK button. This parameter is used only if time program- ming is activated.
  • Page 224 FORCE W Select the day (fig. 17) or the interval of days to program (fig. 18) and confirm with the OK button. Scheduler Set Scheduler Set Monday Wednesday Thursday Tuesday Friday Wednesday Saturday Thursday Sunday Friday Monday-Sunday Saturday Monday-Friday Sunday...
  • Page 225 FORCE W Press navigation button 7 and use contextual buttons Scheduler Set 1 and 2 to set the work mode during the first time band (fig. 21) 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Page 226 FORCE W To restore the time program to the factory Scheduler Set values, press contextual button 3 in the Time Program menu (fig. 26) and confirm Monday with OK. Tuesday Wednesdey Thursday Friday Saturday Sunday Monday-Sunday to confirm fig. 26 The two Heating and DHW hourly programs are independent even in case of Reset to factory value.
  • Page 227 FORCE W Holiday Function Access the "HOLIDAY FUNCTION" menu through the path "USER MENU “HOLIDAY FUNCTION” to set: • Holiday start date. • Holiday end date. The display can activate two types of icons: • - The Holiday function is programmed but not yet active.
  • Page 228 FORCE W Adjust the parallel offset of the curves from 20 to 60 °C OTC Offset 1 (fig. 31), via the parameter “Offset1” and confirm with the OK button. to confirm fig. 29- Parallel curve offset If the room temperature is lower than the desired value, it is advisable to set a higher order curve and vice versa. Pro- ceed by increasing or decreasing in steps of one and check the result in the room.
  • Page 229 FORCE W Adjustments from remote timer control If the boiler is connected to the Remote Timer Control (optional), the previously described adjustments are managed as described in table 1. Table 1 Heating temperature adjustment Adjustment can be made from the Remote Timer Control menu and the boiler control panel.
  • Page 230: Installation

    FORCE W 2. Installation 2.1 General Instructions BOILER INSTALLATION MUST ONLY BE PERFORMED BY QUALIFIED PERSONNEL, IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL MANUAL, THE PROVISIONS OF CURRENT LAW, THE PRESCRIPTIONS OF NATIONAL AND LOCAL STANDARDS AND THE RULES OF PROPER WORKMANSHIP.
  • Page 231 FORCE W High-efficiency circulating pump (optional) The factory setting is suitable for all installations; however, using the selection button (see detail 1 of fig. 33), a different operating strategy can be set de- pending on the system characteristics. fig. 33...
  • Page 232 FORCE W - External control setting Pump speed is determined by the external signal coming from the boiler control unit. PWM type 1: Pump speed is regulated according to the PWM signal. If the cable breaks, the pump accelerates to the maximum speed.
  • Page 233 FORCE W System water characteristics Before installing the FORCE W generator, the new or existing system must be properly cleaned in order to eliminate installation residues, solvents, sludge and contaminants in general that may compromise the effectiveness of the pro- tective conditioning treatments.
  • Page 234 FORCE W Table 2- Chemical conditioners declared suitable and available at our network of Authorized Tech- nical Assistance Centers Description Sentinel type alternative products LIFE PLUS/B - MOLY - MOLY K Molybdenum-based corrosion inhibitor X100 LIFE DUE Noise reduction/anti-scaling maintenance...
  • Page 235 FORCE W Optional kits The following kits are available on request: code 042070X0 - HIGH EFFICIENCY CIRCULATING PUMP KIT- 7m. (A - fig. 34) code 042071X0 - HIGH EFFICIENCY CIRCULATING PUMP KIT- 10m. (A - fig. 34) code 042072X0 - PLUMBING KIT The Kit 042072X0 contains: NON-RETURN VALVE - Female 1”1/2 (B - fig.
  • Page 236 FORCE W Hydraulic circuit examples In the examples described below, the checking/chan- MENU ge of some parameters may be required. To do this it is necessary to access the Technical me- USER From the Home page, press the main Menu button TECHNICIAN (detail 12 - fig.
  • Page 237 FORCE W Two direct heating circuits - Schematic diagram fig. 39 - Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section. Legend (fig. 39 and fig. 40)
  • Page 238 FORCE W - Parameters Each system requires a different parameterization. Follow the access procedure given below. “System Type Menu” Change parameter P.01 of the “System Type Menu” to 4. - Optional features In addition to the electrical connections of the previous figure (necessary for this system configuration) there are options that do not require settings.
  • Page 239 FORCE W One direct heating circuit and one DHW circuit with circulating pump - Schematic diagram fig. 42 - Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section.
  • Page 240 FORCE W - Parameters Each system requires a different parameterization. Follow the access procedure given below. “Configuration - Parameters Menu” Check/Change parameter b02 of the “Transparent Parameters Menu” to 8. Check/Change parameter b08 of the “Transparent Parameters Menu” to 1.
  • Page 241 FORCE W A direct heating circuit and a DHW circuit with diverter valve (3-wire) - Schematic diagram Use diverter valves with 3 wires: - 230V OPENING PHASE - 230V CLOSING PHASE - NEUTRAL with switching times (from all closed to all open) of not more than 90 seconds.
  • Page 242 FORCE W To manage the sliding temperature it is necessary to purchase the external probe accessory code 013018X0 If a hot water tank probe (not supplied) is used, it is necessary to purchase the NTC probe accessory code 1KWMA11W (2 mt.) or code 043005X0 (5 mt.)
  • Page 243 FORCE W Two mixed heating circuits, one direct heating circuit and one DHW circuit with circulating pump - Schematic diagram The zone control card FZ4B can manage different types of systems. An example is given. Use diverter valves with 3 wires:...
  • Page 244 FORCE W - Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...
  • Page 245 FORCE W Legend (fig. 48 and fig. 49) 72a 1st zone (mixed) room thermostat B = NEUTRAL 72b 2nd zone (mixed) room thermostat C = CLOSING PHASE 72c 3rd zone (direct) room thermostat 317a 1st zone (mixed) safety thermostat 130 Hot water tank circulating pump...
  • Page 246: Gas Connection

    FORCE W 2.4 Gas connection Before carrying out the connection, make sure the unit is arranged for operation with the type of fuel available and carefully clean all the pipes of the gas system to remove any residues that could affect proper boiler operation.
  • Page 247 FORCE W External probe (optional) Connect the probe to its respective terminals. The maximum permissible length of the boiler – external probe connection electric cable is 50 m. A common 2-core cable can be used. The external probe should preferably be installed on the North, North-West wall or on the wall with most of the main living room.
  • Page 248 FORCE W For cascade connection NOTE: The boiler’s electronics can manage up to a maximum of 6 modules. 1. Connect the modules as shown in fig. 53 (example with 3 modules) fig. 53 - Connection in cascade A 1st Module...
  • Page 249 FORCE W Generators in cascade: a direct heating circuit and a DHW circuit with circulating pump Schematic diagram The boiler electronics can manage up to a maximum of 6 modules. 3 are given in the example. fig. 54 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 250 FORCE W Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section. 300M 300S 9 10 11 12 13 14 15 16 17 18...
  • Page 251 230Vac lamp “For further cascade, hydraulic and electrical connection diagrams, please consult the website www.ferroli.com in the section dedicated to RESIDENTIAL products, Boilers, FORCE W and, under MANUALS, download the technical docu- ments that give all the installation and configuration specifications:...
  • Page 252: Fume Ducts

    FORCE W 2.6 Fume ducts THE BOILERS MUST BE INSTALLED IN ROOMS THAT MEET THE FUNDA- MENTAL VENTILATION REQUIREMENTS. OTHERWISE THERE IS A DAN- GER OF ASPHYXIA OR POISONING. READ THE INSTALLATION AND MAINTENANCE INSTRUCTIONS BEFORE INSTALLING THE UNIT. ALSO RESPECT THE DESIGN INSTRUCTIONS.
  • Page 253 TERMINAL Calculation examples FORCE W 60: available head 77 Pa 5 meters PIPE Ø80 + 3 BENDS Ø80 = (5 x 4.8) + (3 x 10)= 55<77 = OK 8 meters PIPE Ø80 + 6 CURVE Ø80 = (8 x 4.8) + (6 x 10)= 100>77 = NO Fume ducts If installation of the unit is “type C13 or C33”...
  • Page 254: Condensate Drain Connection

    FORCE W Any horizontal sections of the fume exhaust must be kept sloping slightly towards the boiler, to prevent possible con- densate from flowing back towards the outside and causing dripping. Before proceeding with installation, check with table 5 that the maximum permissible length is not exceeded, bearing in mind that every coaxial bend gives rise to the reduction indicated in the table.
  • Page 255: Service And Maintenance

    Personnel (meeting the professional technical requirements of current regulations) such as the personnel of the Local After-Sales Technical Service. FERROLI declines any liability for damage and/or injury caused by unqualified and unauthorized persons tampering with the unit. 3.1 Adjustments Gas conversion The unit can run on Natural Gas (G20), Liquefied Gas (G30-G31) and Propane-Air (G230).
  • Page 256 FORCE W • For models W 60 and W 80 Undo the screws “B” and remove the “Venturi/gas valve” (fig. 63) unit. Undo the screws “E” and then replace the gas nozzle “F” with that contained in the conversion kit, placing it inside the gasket “G”.
  • Page 257 FORCE W • For Models W 99, W 120 and W 150 Remove the gas valve control unit (fig. 65). Undo the screws “C” (fig. 66) securing the fan and remove the unit (fig. 67). fig. 65 fig. 66 Undo the screws “E” and then replace the gas nozzle “F” with that contained in the conversion kit, placing it inside the gasket “G”.
  • Page 258 FORCE W • For all models Modify the parameter for the type of gas as described below. Reach the screen displayed in fig. 69 by browsing the menu and following the path “USER MENU Maintenance Test Mode Gas Type Selection”. Press contextual buttons 1 and 2 to select the type of gas. Confirm with the OK button.
  • Page 259 FORCE W fig. 70- Maximum adjustment, models W 60 and W 80 fig. 71- Minimum adjustment, models W 60 and W 80 fig. 72- Maximum and minimum adjustment, models W 99, W 120 and W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 260 FORCE W TEST mode activation Reach the screen shown in fig. 73, navigating the following menu path: "USER MENU Maintenance Test Mode Test mode”. The boiler will light, gradually reaching the maximum heating power (Range Rated) set as described in the next section.
  • Page 261 FORCE W TECHNICAL MENU ONLY QUALIFIED PERSONNEL CAN ACCESS THE SERVICE MENU AND MODIFY PARAMETERS. The Technical Menu can only be accessed after entering the code 4 1 8. It is valid for 15 minutes. Configuration - Parameters Menu 16 parameters are available, indicated by the letter “b”, which are not modifiable from Remote Timer Control.
  • Page 262 FORCE W Parameter Description Range W 60 W 80 W 99 W 120 W 150 Modulating pump min. speed 0-100% Modulating pump start speed 0-100% Modulating pump max. speed 30-100% Pump deactivation temperature during Post-Cir- 0-100°C culation Pump activation hysteresis temperature during 0-20°C...
  • Page 263 FORCE W System Type - Parameters Menu 23 parameters are available, indicated by the letter “P.” which are not modifiable from Remote Timer Control. Parameter Description Range W 60 W 80 W 99 W 120 W 150 0 = Normal heating request...
  • Page 264: Commissioning

    FORCE W 3.2 Commissioning Checks to be done at first lighting, and after all maintenance operations that invol- ved disconnection from the systems or work on safety devices or parts of the boiler: Before lighting the boiler • Open any on-off valves between the boiler and the systems.
  • Page 265 FORCE W • Check and cleaning of electrodes, which must be free of deposits and properly positioned. • Check of gaskets and seals (burner, sealed chamber, etc.). • Check and cleaning of sludge remover filters and system filters. • Check, cleaning and filling of condensate drain traps.
  • Page 266 FORCE W Extraordinary maintenance and replacement of components Electrode replacement Exchanger cleaning cod. 3541V233 - Rev 00 - 06/2022...
  • Page 267: Troubleshooting

    FORCE W 3.4 Troubleshooting Diagnostics The boiler is equipped with an advanced self-diagnosis system. In case of a boiler fault, the display lights up indicating the fault code and, in case of cascade connection, the module number. • There are faults that cause permanent shutdowns which can be reset by pressing the OK button for one second or with the RESET button on the remote timer control (optional) if installed.
  • Page 268 FORCE W Fault Fault Possible cause Cure code Sensor damaged Return sensor fault Wiring shorted Check the wiring or replace the sensor Wiring disconnected Sensor damaged DHW sensor fault Wiring shorted Check the wiring or replace the sensor Wiring disconnected...
  • Page 269: Technical Data And Characteristics

    FORCE W 4. Technical data and characteristics Legend of figures cap. 4 "Technical data and characteristics" Gas inlet - Ø 3/4” System flow - Ø 1” 1/2 System return - Ø 1” 1/2 Safety valve Heating circulating pump (not supplied)
  • Page 270: Dimensions And Connections

    FORCE W 4.1 Dimensions and connections fig. 76- Front view fig. 77- Side view fig. 78- Top view fig. 79- Bottom view cod. 3541V233 - Rev 00 - 06/2022...
  • Page 271: General View

    FORCE W 4.2 General view fig. 81- General view - model FORCE W 99 and FORCE W 120 fig. 80- General view - model FORCE W 60 and FORCE W 80 fig. 82- General view - model FORCE W 150...
  • Page 272: Hydraulic Circuit

    FORCE W 4.3 Hydraulic circuit fig. 83- Hydraulic circuit cod. 3541V233 - Rev 00 - 06/2022...
  • Page 273: Technical Data Table

    FORCE W 4.4 Technical data table The column on the right gives the abbreviation used on the data plate. cod. 3541V233 - Rev 00 - 06/2022...
  • Page 274 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 275: Erp Tables

    FORCE W 4.5 ErP tables cod. 3541V233 - Rev 00 - 06/2022...
  • Page 276 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 277 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 278 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 279 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 280: Diagrams

    FORCE W 4.6 Diagrams Pressure loss fig. 84- Pressure loss diagram - models FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 85- Pressure loss diagram - models FORCE W 150 Delivery - m...
  • Page 281: Wiring Diagrams

    FORCE W 4.7 Wiring diagrams The legend of the figures is on page 269. ATTENTION: Remove the jumper on the terminal block before connecting the room thermostat or the remote timer control. ATTENTION: To connect the 3-way valve (terminals 13 - 14 - 15), refer to the diagrams of fig. 86 and fig. 87.
  • Page 282 FORCE W fig. 89- Wiring diagram - models FORCE W 60 and FORCE W 80 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 283 FORCE W fig. 90- Wiring diagram - models FORCE W 99, FORCE W 120 and FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 284 FORCE W • Lire attentivement les avertissements repris dans le présent ge d'origine. Le non-respect de ce qui précède compromet les manuel d'instructions fournissant des indications importantes conditions de sécurité de l'appareil. pour la sécurité de l'installation, son utilisation et son entretien.
  • Page 285 FORCE W 1 Instructions d’utilisation ..................... 286 1.1 Introduction............................286 1.2 Tableau des commandes ........................286 1.3 Allumage et extinction ........................290 1.4 Réglages ............................291 2 Installation ..........................299 2.1 Dispositions générales ........................299 2.2 Emplacement ............................. 299 2.3 Raccordements hydrauliques ......................299 2.4 Raccordement gaz ..........................
  • Page 286: Instructions D'utilisation

    FORCE W est un générateur thermique pour chauffage, prémélangé à condensation à très haut rendement et très faible niveau d’émissions, fonctionnant au gaz naturel (G20), gaz liquide (G30-G31) et air propané (G230), équipé...
  • Page 287 FORCE W Touches directes Les touches directes (rep. 8, 9, 10 - fig. 1) ont toujours la même fonction. Touches de navigation/menu Les touches navigation/menu (rep. 5, 6, 7, 11, 12, 13 - fig. 1) servent à naviguer parmi les différents menus disponibles sur le panneau de contrôle.
  • Page 288 FORCE W ENTRETIEN Voir fig. 73 Mode TEST Voir fig. 69 Mode TEST Sélection type de gaz Mode test cascade Voir “Information de Service” on page 296 Information de Service Voir “Date Intervention Service” on page 296 Date Intervention Service CONFIGURATIONS Voir fig.
  • Page 289 FORCE W Exclusion du ballon (ECO) L'utilisateur peut exclure le chauffage/maintien de la température dans le ballon En cas d'exclusion, l'eau chaude sanitaire ne sera pas disponible. Le ballon peut être désactivé par l'utilisateur (mode ECO) en ap- puyant sur le bouton eco/confort (part. 10 - fig. 1). En 23°C...
  • Page 290: Allumage Et Extinction

    FORCE W 1.3 Allumage et extinction Allumage de la chaudière Appuyer sur le bouton marche/arrêt (par 14 - fig. 1). que le thermostat d'ambiance relève un besoin thermique (demande) En appuyant sur la touche contextuelle 1 il est possi- ble de choisir la langue souhaitée et de la valider avec la touche «...
  • Page 291: Réglages

    FORCE W Extinction de la chaudière À partir de la page principale/Accueil, appuyer sur la Pour débrancher complètement l'appareil de l'alimen- touche contextuelle et confirmer avec la touche tation électrique, appuyez sur la touche part. 14 fig. 1. Au moment où l'on éteint la chaudière, la carte électro- nique reste encore sous tension.
  • Page 292 FORCE W Réduction de la température de chauffage Accéder au menu « Temp réglage réduction » pour Température de consigne réduit faire varier la température d'un minimum de 0°C à un maximum de 50°. Confirmer en appuyant sur OK. Ce paramètre n'est utilisé que si la program- mation horaire est activée.
  • Page 293 FORCE W Sélectionner le jour (fig. 17) ou l'intervalle de jours à programmer (fig. 18) et valider avec la touche OK. Programmation horaires Programmation horaires Mercredi Lundi Jeudi Mardi Vendredi Mercredi Samedi Jeudi Dimanche Vendredi Lundi-Dimanche Samedi Lundi-Vendredi Dimanche Samedi-Dimanche...
  • Page 294 FORCE W Appuyer sur la touche de navigation 7 et utiliser les Programmation horaires touches contextuelles 1 et 2 pour régler le mode de fonctionnement pendant la première tranche horaire 06:00 - 16:00 (fig. 21) --:-- - --:-- --:-- - --:--...
  • Page 295 FORCE W Pour restaurer le programme horaire aux va- Programmation horaires leurs d'usine, appuyer sur la touche contex- tuelle 3 dans le menu Programme horaire Lundi (fig. 26) et valider par OK. Mardi Mercredi Jeudi Vendredi Samedi Dimanche Lundi-Dimanche pour confirmer fig.
  • Page 296 FORCE W Fonction vacances Accéder au menu « FONCTION VACANCES » à travers le parcours « MENU UTILISATEUR « FONCTION VA- CANCES » pour pouvoir définir : • Date début Vacances. • Date fin Vacances. L'afficheur peut activer deux types d'icônes : •...
  • Page 297 FORCE W Régler le déplacement parallèle des courbes de 20 à Décalage paral. de pente 1 60°C (fig. 31), à l'aide du paramètre « Offset1 » et va- lider avec la touche OK. pour confirmer fig. 29- Déplacement parallèle des courbes Si la température ambiante est inférieure à...
  • Page 298 FORCE W Réglages à partir de la chronocommande à distance Si la chaudière est reliée à la chronocommande à distance (option), les réglages ci-dessus seront gérés com- me indiqué dans le tableau tableau 1. Tableau 1 Réglage de la température de chauf- Le réglage peut être effectué...
  • Page 299: Installation

    FORCE W 2. Installation 2.1 Dispositions générales L'INSTALLATION DE LA CHAUDIÈRE DOIT ÊTRE EFFECTUÉE CONFORMÉMENT AUX TEXTES RÉGLEMENTAI- RES ET RÈGLES DE L'ART EN VIGUEUR, SUIVANT LES INSTRUCTIONS DU CONSTRUCTEUR ET PAR UN PRO- FESSIONNEL QUALIFIÉ. 2.2 Emplacement Le générateur doit être installé dans un local approprié, muni d'ouvertures d'aération vers l'extérieur, conformément aux normes en vigueur.
  • Page 300 FORCE W Circulateur haute efficacité (en option) Le réglage d'usine convient à toutes les installations ; cependant, il est possible de définir, à l'aide de la tou- che de sélection (voir détail 1 de fig. 33), une stratégie de fonctionnement différente selon les caractéristi- ques de l'installation.
  • Page 301 FORCE W - Réglage commande extérieure La vitesse de la pompe est déterminée par le signal extérieur provenant de l’unité de contrôle de la chaudière. PWM type 1 : La vitesse de la pompe est réglée en fonction du signal PWM. En cas de rupture du câble, la pompe accélère jusqu'à...
  • Page 302 FORCE W Caractéristiques de l'eau de l'installation Avant de procéder à l'installation du générateur FORCE W, l'installation, nouvelle ou existante, doit être correctement nettoyée afin d'éliminer les résidus d'installation, les solvants, les boues et les contaminants en général pouvant em- pêcher l'efficacité...
  • Page 303 FORCE W Tableau 2- Les agents de conditionnement chimiques déclarés appropriés et disponibles auprès de notre réseau de centres d'assistance technique agréés Description Produits alternatifs type Sentinel LIFE PLUS/B - MOLY - MOLY K Inhibiteur de corrosion a base de molybdène...
  • Page 304 FORCE W Kit options Sur demande, les kits suivants sont disponibles : réf. 042070X0 - KIT CIRCULATEUR HAUTE EFFICACITÉ - 7m. (A - fig. 34) réf. 042071X0 - KIT CIRCULATEUR HAUTE EFFICACITÉ - 10m. (A - fig. 34) réf. 042072X0 - KIT HYDRAULIQUE Le kit 042072X0 comprend : CLAPET ANTI-RETOUR - Femelle 1”1/2 (B - fig.
  • Page 305 FORCE W Exemples de circuits hydrauliques Dans les exemples décrits ci-après, il pourrait être né- MENU cessaire de vérifier/modifier certains paramètres. Pour cela, accéder d'abord au menu Technicien. UTILISATEUR À partir de la page principale (Accueil), appuyer sur la touche Menu principal (rep. 12 - fig. 1).
  • Page 306 FORCE W Deux circuits chauffage directs - Schéma de principe fig. 39 - Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant. Légende (fig. 39 et fig. 40) 9 10 11 12 13 14 15 16 17 18 Thermostat d'ambiance 1ère zone (directe)
  • Page 307 FORCE W - Paramètres Chaque circuit doit être configuré individuellement. Suivre la procédure d'accès indiquée ci-après. « Menu Type Installation » Modifier le paramètre P.01 du « Menu Type Installation » sur 4. - Fonctions optionnelles En plus des connexions électriques de la figure précédente (nécessaires pour cette configuration système), il existe des options qui ne nécessitent aucun réglage.
  • Page 308 FORCE W Un circuit chauffage direct et un circuit eau chaude sanitaire avec circulateur - Schéma de principe fig. 42 - Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant.
  • Page 309 FORCE W - Paramètres Chaque circuit doit être configuré individuellement. Suivre la procédure d'accès indiquée ci-après. « Menu Paramètres - Configuration » Vérifier/Modifier paramètre b02 du « Menu Paramètres Transparents » sur 8. Vérifier/Modifier paramètre b08 du « Menu Paramètres Transparents » sur 1.
  • Page 310 FORCE W Un circuit chauffage direct et un circuit eau chaude sanitaire avec by-pass (3 fils) - Schéma de principe Utiliser des by-pass à 3 fils : - PHASE D’OUVERTURE 230 V - PHASE DE FERMETURE 230 V - NEUTRE avec temps de commutation (de fermé...
  • Page 311 FORCE W Pour contrôler la température évolutive, commander l'accessoire sonde extérieure, réf. 013018X0 En cas d'utilisation d'une sonde ballon (non fournie), commander la sonde accessoire NTC, réf. 1KWMA11W (2 m) ou réf. 043005X0 (5 m) En cas d'utilisation d'un thermostat ballon (non fourni), commander le kit accessoire, réf. 013017X0 (à brancher à...
  • Page 312 FORCE W Deux circuits chauffage mélangés, un circuit chauffage direct et un circuit eau chaude sanitaire avec circulateur - Schéma de principe La carte contrôle zones FZ4B peut commander plusieurs types d'installation. Type d'installation cité comme exemple. Utiliser des by-pass à 3 fils : - PHASE D’OUVERTURE 230 V...
  • Page 313 FORCE W - Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...
  • Page 314 FORCE W Légende (fig. 48 et fig. 49) 72a Thermostat d'ambiance 1ère zone (mélangée) B = NEUTRE 72b Thermostat d'ambiance 2e zone (mélangée) C = PHASE DE FERMETURE 72c Thermostat d'ambiance 3e zone (directe) 317a Thermostat de sécurité 1ère zone (mélangée) 130 Circulateur ballon 317b Thermostat de sécurité...
  • Page 315: Raccordement Gaz

    FORCE W 2.4 Raccordement gaz Avant d'effectuer le raccordement, veiller à ce que l'appareil soit préparé pour fon- ctionner avec le type de combustible disponible et prendre soin de bien nettoyer les conduites du circuit afin d'en retirer tout résidu pouvant compromettre le bon fonctionnement de la chaudière.
  • Page 316 FORCE W Sonde extérieure (option) Relier la sonde aux bornes La longueur maximale admissible du câble électrique de raccordement chaudière - sonde extérieure est de 50 m. Un câble à 2 conducteurs commun peut être utilisé. La sonde extérieure doit être installée de préférence sur le mur orienté...
  • Page 317 FORCE W Pour le montage en cascade REMARQUE : l'électronique de la chaudière est en mesure de gérer jusqu'à 6 modules maximum. 1. Relier les modules comme le montre la fig. 53 (exemple avec 3 modules) fig. 53 - Montage en cascade...
  • Page 318 FORCE W Générateurs en cascade : un circuit de chauffage direct et un circuit sanitaire avec circulateur Schéma de principe L'électronique de la chaudière est capable de gérer jusqu'à 6 modules maximum. L’exemple en montre 3. fig. 54 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 319 FORCE W Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant. 300M 300S 9 10 11 12 13 14 15 16 17 18 9 10 11 12 13 14 15 16 17 18...
  • Page 320 230 Vca « Pour plus de schémas de raccordement en cascade, hydraulique et électrique, consulter le site www.ferroli.com dans la rubrique dédiée aux produits RESIDENTIEL, Chaudières, FORCE W et à télécharger les documents techniques qui contiennent toutes les spécifications et configuration d'installation à...
  • Page 321: Conduits De Fumée

    FORCE W 2.6 Conduits de fumée LES CHAUDIÈRES DOIVENT ÊTRE INSTALLÉES DANS DES PIÈCES RÉPONDANT AUX EXIGENCES D'AÉRATION DE BASE. À DÉFAUT, IL Y A UN DANGER D'ASPHYXIE OU D'EMPOISONNEMENT. LIRE LES CONSIGNES D'INSTALLATION ET D'ENTRETIEN AVANT D'IN- STALLER L'APPAREIL.
  • Page 322 TERMINAL Exemples de calcul FORCE W 60: hauteur d’élévation disponible 77 Pa 5 mètres TUYAU Ø80 + 3 COUDES Ø80 = (5 x 4,8) + (3 x 10)= 55<77 = OK 8 mètres TUYAU Ø80 + 6 COUDES Ø80 = (8 x 4,8) + (6 x 10)= 100>77 = NO Conduits de fumée...
  • Page 323: Raccordement De L'évacuation Des Condensats

    FORCE W Les éventuelles parties horizontales de l'évacuation des fumées doivent avoir une légère pente vers la chaudière pour éviter que l'éventuelle eau de condensation ne coule et ne goutte vers l'extérieur. Avant de procéder à l'installation, consulter le tableau tableau 5 que la longueur maximale admissible ne soit dépassée, compte tenu que la mise en place d'un coude coaxial supplémentaire entraîne la réduction de la longueur indiquée dans...
  • Page 324: Utilisation Et Entretien

    SAV. FERROLI Toute responsabilité du constructeur est exclue pour les dommages aux biens et/ou personnes causés par des modification de l’appareil par des personnes non qualifiées et non autorisées.
  • Page 325 FORCE W • Pour modèles W 60 et W 80 Dévisser les vis « B » et retirer le groupe « Venturi/vanne à gaz » (fig. 63). Dévisser les vis « E » puis remplacer le gicleur-buse à gaz « F » par celle contenue dans le kit de transformation en la plaçant à...
  • Page 326 FORCE W • Pour les modèles W 99, W 120 et W 150 Extraire le boîtier de commande de la vanne à gaz (fig. 65). Dévisser les vis « C » (fig. 66) qui fixent le ventilateur et extraire le groupe (fig. 67).
  • Page 327 FORCE W • Pour tous les modèles Modifier le paramètre concernant le type de gaz en procédant comme décrit ci-après. Accéder à la page qui s'affiche sur fig. 69 en naviguant dans le menu à travers le parcours « MENU UTILISATEUR »...
  • Page 328 FORCE W fig. 70- Réglage maximum modèles W 60 et W 80 fig. 71- Réglage minimum modèles W 60 et W 80 fig. 72- Réglage maxi et mini modèles W 99, W 120 et W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 329 FORCE W Activation du mode TEST Accéder à la page qui s'affiche sur fig. 73 en naviguant dans le menu à travers le parcours « MENU UTILISATEUR » Entretien Mode TEST Mode test ». La chaudière s'allume à la puissance maximale de chauffage (Range Rated) fixée, comme l'indique le paragraphe sui- vant, de façon progressive.
  • Page 330 FORCE W MENU TECHNICIEN L’ACCÈS AU MENU SERVICE ET LA MODIFICATION DES PARAMÈTRES NE PEUVENT ÊTRE EFFECTUÉS QUE PAR UN PERSONNEL QUALIFIÉ. L'accès au Menu Technicien n'est possible qu'après avoir saisi le code 4 1 8. La durée de validité de celui-ci est de 15 minutes.
  • Page 331 FORCE W Menu Paramètres - Transparents 31 paramètres indiqués par la lettre « P » sont disponibles : ils sont modifiables à partir de la chronocommande à di- stance. Tableau 7- Paramètres - Transparents Paramètre Description Plage W 60 W 80...
  • Page 332 FORCE W Paramètre Description Plage W 60 W 80 W 99 W 120 W 150 Température protection échangeur primaire 0-80°C Valeur mini pression installation Valeur nominale pression installation 0 = Non F43, Déclenchement de la protection échangeur 1-15 = 1-15 °C/ seconde Hystérésis chauffage après allumage...
  • Page 333: Mise En Service

    FORCE W Paramètre Description Plage W 60 W 80 W 99 W 120 W 150 0-10 Vcc Tension chauffage OFF (Contrôle en P.17 0,1-10 Vcc Puissance)** 0-10 Vcc Tension chauffage ON (Contrôle en P.18 0,1-10 Vcc Puissance)** 0-10 Vcc Puissance maximale (Contrôle en Puis- P.19...
  • Page 334: Entretien

    FORCE W 3.3 Entretien AVERTISSEMENTS TOUTES LES OPÉRATIONS D'ENTRETIEN ET DE REMPLACEMENT DOI- VENT ÊTRE CONFIÉES À DES TECHNICIENS SPÉCIALISÉS ET QUALIFIÉS. Avant d'effectuer une quelconque opération à l'intérieur de la chaudière, la mettre hors tension et fermer le robinet du gaz en amont Le non-respect de cette consigne entraîne le risque d'explosion, d'électrocution, d'asphyxie ou...
  • Page 335 FORCE W Ouverture du panneau avant Certains composants logés à l’intérieur de l’unité peuvent atteindre des tem- pératures élevées pouvant provoquer des brûlures graves.Avant d’effectuer une opération quelconque, attendre le refroidissement desdits composants ou bien porter des gants de protection appropriés.
  • Page 336 FORCE W Entretien extraordinaire et remplacement des composants Remplacement de l’électrode Nettoyage de l’échangeur cod. 3541V233 - Rev 00 - 06/2022...
  • Page 337: Dépannage

    FORCE W 3.4 Dépannage Diagnostic La chaudière est équipée d'un dispositif d'autodiagnostic avancé. Dans le cas d’anomalie ou de dysfonctionnement de la chaudière, l’afficheur s’illumine indiquant le code d'erreur et, dans le cas de raccordement en cascade, le numéro du module.
  • Page 338 FORCE W Code Anomalie Causes probables Solution anomalie Capteur endommagé Anomalie capteur de Câblage en court-circuit Contrôler le câblage ou remplacer le capteur retour Câblage interrompu Capteur endommagé Anomalie capteur d'eau Câblage en court-circuit Contrôler le câblage ou remplacer le capteur chaude sanitaire Câblage interrompu...
  • Page 339: Caractéristiques Et Données Techniques

    FORCE W 4. Caractéristiques et données techniques Légende des figures cap. 4 "Caractéristiques et données techniques" Arrivée gaz - Ø 3/4” Départ installation - Ø 1” 1/2 Retour installation - Ø 1” 1/2 Soupape de sécurité Ventilateur Circulateur circuit chauffage (non fourni) Capteur de température chauffage...
  • Page 340: Dimensions Et Raccords

    FORCE W 4.1 Dimensions et raccords fig. 76- Vue de face fig. 77- Vue latérale fig. 78- Vue de dessus fig. 79- Vue de dessous cod. 3541V233 - Rev 00 - 06/2022...
  • Page 341: Vue Générale

    FORCE W 4.2 Vue générale fig. 81- Vue générale mod. FORCE W 99 et FORCE W 120 fig. 80- Vue générale mod. FORCE W 60 et FORCE W 80 fig. 82- Vue générale mod. FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 342: Circuit Hydraulique

    FORCE W 4.3 - Circuit hydraulique fig. 83- Circuit hydraulique cod. 3541V233 - Rev 00 - 06/2022...
  • Page 343: Tableau Des Caractéristiques Techniques

    FORCE W 4.4 Tableau des caractéristiques techniques La colonne de droite indique l'abréviation utilisée sur la plaquette des caractéristiques techniques. cod. 3541V233 - Rev 00 - 06/2022...
  • Page 344 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 345 FORCE W 4.5 Tableaux ErP cod. 3541V233 - Rev 00 - 06/2022...
  • Page 346 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 347 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 348 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 349 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 350: Diagrammes

    4.6 Diagrammes Perte de charge fig. 84- Diagramme perte de charge modèles FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 85- Diagramme perte de charge modèles FORCE W 150 Débit - m...
  • Page 351: Schémas Électriques

    FORCE W 4.7 Schémas électriques La légende des figures se trouve à page 339. ATTENTION : Avant de brancher le thermostat d'ambiance ou la chronocommande à distance, retirer le cavalier du bornier. ATTENTION : pour raccorder la vanne 3 voies (bornes 13 - 14 - 15), se référer aux schémas de fig. 86 et fig. 87.
  • Page 352 FORCE W fig. 89- Schéma électrique modèles FORCE W 60 et FORCE W 80 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 353 FORCE W fig. 90- Schéma électrique modèles FORCE W 99, FORCE W 120 et FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 354 FORCE W Qnw (Hi) Qn (Hi) Pn 80-60°C Pn 50-30°C tmax 19 = : XX - XX..05 = Serial Number 1905G80012 G8 = 1905G80012 0012 = 8 028693 869669 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 355 FORCE W 1 Инструкции по эксплуатации................... 356 1.1 Предисловие ............................. 356 1.2 Панель управления .......................... 356 1.3 Включение и выключение ........................ 360 1.4 Регулировки ............................361 2 Установка..........................369 2.1 Указания общего характера......................369 2.2 Место установки ..........................369 2.3 Гидравлические подключения ......................369 2.4 Газовые...
  • Page 356: Инструкции По Эксплуатации

    1.1 Предисловие Уважаемый покупатель! Благодарим вас за выбор FORCE W, настенного котла с закрытой камерой сгорания FERROLI прогрессивного дизайна, выполненного по передовым технологиям и отличающегося высокой надежностью и качеством конструкции. Просим Вас внимательно прочитать настоящее руководство, поскольку в нем содержатся важные указания по безопасности установки, эксплуатации...
  • Page 357 FORCE W Однозначные клавиши Однозначные клавиши (поз. 8, 9, 10 - рис. 1) всегда выполняют одну и ту же функцию. Клавиши навигации/меню Клавиши навигации/меню (поз. 5, 6, 7, 11, 12, 13 - рис. 1) служат для навигации между разными меню на панели управления.
  • Page 358 FORCE W ТЕХНИЧЕСКОЕ ОБСЛУЖИВАНИЕ См. рис. 73 Тестовый режим См. рис. 69 Выбор типа газа Тестовый режим Тестовый режим каскад Информация о Сервисной См. “Информация о Сервисной службе” on page 366 службе Дата проведения сервисных См. “Дата проведения сервисных операций” on page 366 операций...
  • Page 359 FORCE W Исключение бойлера (режим Еconomy) Пользователь имеет возможность исключать систему нагрева/поддержания температуры воды в бойлере. В этом случае котлом не вырабатывается вода для ГВС. Котел может быть отключен пользователем (режим ECO) нажатием кнопки Eco/Comfort (поз. 10 - рис. 1). В...
  • Page 360: Включение И Выключение

    FORCE W 1.3 Включение и выключение Включение котла Нажмите на кнопку включения/выключения (поз. 14 - рис. 1). Нажав контекстную кнопку 1, можно выбрать желаемый язык и подтвердить его клавишей «ОК». Нажав контекстную кнопку 3, можно прервать режим FH. Если не выбран ни один из двух вышеописанных...
  • Page 361: Регулировки

    FORCE W Выключение котла В главном экранном окне (Home) нажмите на контекстную клавишу и подтвердите с помощью кнопки Когда котел выключен, на электронную плату продолжает подаваться электрическое питание. В этом случае не происходит нагрев воды для ГВС (при наличии внешнего бойлера) и отопления Остается...
  • Page 362 FORCE W Снижение температуры отопления Войдите в меню “Понижение температуры Изменение установки ГВС регулировки” для изменения температуры от минимум 0°C до максимум 50°С. Подтвердите с помощью кнопки Этот параметр используется, только если включено программирование графика работы по часам. См. *** 'Программирование графика...
  • Page 363 FORCE W Выберите день (рис. 17) или интервал из нескольких дней для программирования (рис. 18) и подтвердите кнопкой OK. Установка расписания Установка расписания среда Понедельник Четверг Вторник Пятница Среда Суббота Четверг воскресенье Пятница понедельник-воскресенье Суббота Понедельник-Пятница воскресенье понедельник-воскресенье понедельник-воскресенье подтвердить...
  • Page 364 FORCE W Нажмите кнопку навигации 7 и используйте контекстные Установка расписания кнопки 1 и 2, чтобы задать режим работы в течение первого временного интервала (рис. 21). Копировать в Следующий День Сохранить и выйти подтвердить рис. 21 Затем нажмите кнопку навигации 7, чтобы задать (при необходимости) следующие временные интервалы (рис. 22, рис. 23 и...
  • Page 365 FORCE W Чтобы восстановить заводские значения Установка расписания графика работы, нажмите контекстную кнопку 3 в меню График работы (рис. 26) и Понедельник подтвердите с помощью OK. Вторник Среда Четверг Пятница Суббота воскресенье понедельник-воскресенье подтвердить рис. 26 Две часовые программы отопления и ГВС независимы даже в случае возврата к заводским значениям.
  • Page 366 FORCE W Функция отпуска Войдите в меню “ФУНКЦИЯ ОТПУСКА” по маршруту “МЕНЮ ПОЛЬЗОВАТЕЛЯ “ФУНКЦИЯ ОТПУСКА”, чтобы задать: • Дату начала отпуска. • Дату окончания отпуска. На дисплее могут появится два типа иконок: • - Функция Отпуска запрограммирована, но не активирована.
  • Page 367 FORCE W Отрегулируйте параллельное смещение кривых от 20 до Смещение 1 60°C (рис. 31), используя параметр “Offset1”, и подтвердите клавишей OK. подтвердить рис. 29- Параллельное смещение кривых Если температура в помещении оказывается ниже желаемой, рекомендуется выбрать характеристику более высокого порядка и наоборот. Увеличивая или уменьшая на одну единицу порядок кривой, оцените, каким образом это скажется на...
  • Page 368 FORCE W Регулирование с дистационного пульта управления с таймером Если к котлу подключено устройство дистанционного управления с таймером (опция), вышеописанные регулировки производятся в соответствии с указаниями, приведенными в таблица 1. Таблица 1 Регулировка температуры воды в Регулировку можно произвести как из меню пульта ДУ с таймером, так и с панели...
  • Page 369: Установка

    FORCE W 2. Установка 2.1 Указания общего характера УСТАНОВКА И НАСТРОЙКА ГОРЕЛКИ ДОЛЖНА ОСУЩЕСТВЛЯТЬСЯ ТОЛЬКО СПЕЦИАЛИЗИРОВАННЫМ ПЕРСОНАЛОМ, ИМЕЮЩИМ ПРОВЕРЕННУЮ КВАЛИФИКАЦИЮ, ПРИ СОБЛЮДЕНИИ ПРИВЕДЕННЫХ В НАСТОЯЩЕМ ТЕХНИЧЕСКОМ РУКОВОДСТВЕ УКАЗАНИЙ, ПРЕДПИСАНИЙ ДЕЙСТВУЮЩЕГО ЗАКОНОДАТЕЛЬСТВА, ПОЛОЖЕНИЙ МЕСТНЫХ НОРМ И ПРАВИЛ, И В СООТВЕТСТВИИ С ПРИНЯТЫМИ ТЕХНИЧЕСКИМИ ТРЕБОВАНИЯМИ.
  • Page 370 FORCE W Высокопроизводительный циркуляционный насос (опция) Заводская настройка подходит для всех установок; тем не менее, с помощью клавиши выбора (см. выноску 1 на рис. 33) можно задать другую стратегию работы в зависимости от характеристик системы. рис. 33 В нормальном режиме работы светодиод горит зеленым светом...
  • Page 371 FORCE W - Настройка внешнего устройства управления Скорость насоса определяется внешним сигналом от блока управления котлом. ШИМ типа 1: Скорость насоса регулируется в соответствии с ШИМ-сигналом. При обрыве кабеля насос разгоняется до максимальной скорости. ШИМ типа 2:Скорость насоса регулируется в соответствии с ШИМ-сигналом. При обрыве кабеля насос останавливается.
  • Page 372 FORCE W Характеристики воды в системе Перед установкой генератора FORCE W система, будь она новой или уже эксплуатируемой, должна быть должным образом очищена, чтобы удалить загрязнения, оставшиеся после монтажа, растворители, шлам и загрязняющие вещества в целом, поскольку они могут нарушить эффективность защитных кондиционирующих присадок. Используйте нейтральные...
  • Page 373 FORCE W Таблица 2- Рекомендуемые химические кондиционирующие присадки, доступные в нашей авторизованной сервисной сети Альтернативные средства типа Описание Sentinel LIFE PLUS/B - MOLY - MOLY K Антикоррозийное средство на основе молибдена X100 Шумоподавление/профилактическая защита от LIFE DUE X200 накипи BIO KILL Биоцидное...
  • Page 374 FORCE W Дополнительные комплекты оснащения По заказу поставляются следующие комплекты: арт. 042070X0 - КОМПЛЕКТ ВЫСОКОПРОИЗВОДИТЕЛЬНОГО ЦИРКУЛЯЦИОННОГО НАСОСА - 7 м (A - рис. 34) арт. 042071X0 - КОМПЛЕКТ ВЫСОКОПРОИЗВОДИТЕЛЬНОГО ЦИРКУЛЯЦИОННОГО НАСОСА - 10 м (A - рис. 34) арт. 042072X0 - ГИДРАВЛИЧЕСКИЙ КОМПЛЕКТ...
  • Page 375 FORCE W Примеры гидравлических контуров В нижеприведенных примерах может потребоваться МЕНЮ проверить/изменить некоторые параметры. Для этого необходимо войти в меню «Техника». ПОЛЬЗОВАТ В главном экранном окне (Home) нажмите на клавишу «Главного меню» (поз. 12 - рис. 1). ТЕХНИК Войдите в меню “Техника" путем нажатия на контекстную...
  • Page 376 FORCE W Два прямых контура отопления - Принципиальная схема рис. 39 - Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа. Спецификация (рис. 39 и рис. 40) 9 10 11 12 13 14 15 16 17 18 Комнатный...
  • Page 377 FORCE W - Параметры Каждая система нуждается в различной настройке параметров. Необходимо следовать приведенной далее процедуре. Меню «Тип системы» Измените параметр P.01 в меню "Тип системы” на 4. - Дополнительные функции В дополнение к электрическим соединениям на предыдущем рисунке (необходимым для данной конфигурации системы) есть...
  • Page 378 FORCE W Прямой отопительный контур и контур ГВС с циркуляционным насосом. - Принципиальная схема рис. 42 - Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа.
  • Page 379 FORCE W - Параметры Каждая система нуждается в различной настройке параметров. Необходимо следовать приведенной далее процедуре. Меню "Параметры - Конфигурация" Проверьте/измените параметр b02 в меню "Прозрачных параметров" на 8. Проверьте/измените параметр b08 в меню "Прозрачных параметров" на 1. Проверьте/измените параметры b04, b05 и b06 меню "Прозрачных параметров" в соответствии со значениями, приведенными...
  • Page 380 FORCE W Прямой отопительный контур и контур ГВС с распределительным клапаном (3-проводной) - Принципиальная схема Используйте 3-проводные отводящие клапаны: - ФАЗА РАЗМЫКАНИЯ 230 В - ФАЗА ЗАМЫКАНИЯ 230 В - НЕЙТРАЛЬ со временем переключения (от полностью замкнутого до полностью разомкнутого) не более 90 секунд.
  • Page 381 FORCE W Для работы с плавающей температурой необходимо приобрести факультативный датчик внешней температуры, арт. 013018X0 В случае использования датчика бойлера (не входящего в комплект поставки) необходимо приобрести факультативный датчик NTC, арт. 1KWMA11W (2 м) или арт. 043005X0 (5 м). В случае использования термостата бойлера (не входящего в комплект поставки) необходимо приобрести...
  • Page 382 FORCE W Два отопительных контура со смесительным клапаном, прямой отопительный контур и контур ГВС с циркуляционным насосом - Принципиальная схема Плата контроля зон FZ4B может управлять отопительными системами различных типов. На рисунке приводится пример. Используйте 3-проводные отводящие клапаны: - ФАЗА РАЗМЫКАНИЯ 230 В...
  • Page 383 FORCE W - Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...
  • Page 384 FORCE W Спецификация (рис. 48 и рис. 49) B = НЕЙТРАЛЬНАЯ ФАЗА Комнатный термостат 1-й зоны (со смесительным клапаном) C = ФАЗА ЗАМЫКАНИЯ Комнатный термостат 2-й зоны (со смесительным 317a Предохранительный термостат 1-й зоны (со клапаном) смесительным клапаном) Комнатный термостат 3-й зоны (прямого контура) 317b Предохранительный...
  • Page 385: Газовые Соединения

    FORCE W 2.4 Газовые соединения Перед выполнением подключения удостоверьтесь, что котел отрегулирован для работы на имеющемся в Вашей магистрали газе и тщательно прочистите все газовые трубы для удаления остаточных загрязнений или посторонних включений, могущих помешать правильной работе агрегата. Газ подключается к соответствующему патрубку (см. рис. 79 ) с соблюдением действующих норм, с использованием жесткой...
  • Page 386 FORCE W Термостат комнатной температуры ВНИМАНИЕ: ТЕРМОСТАТ КОМНАТНОЙ ТЕМПЕРАТУРЫ ДОЛЖЕН БЫТЬ УСТРОЙСТВОМ С КОНТАКТАМИ НЕ ПОД НАПРЯЖЕНИЕМ. ПРИ ПОДАЧЕ НАПРЯЖЕНИЯ В НА КЛЕММЫ ТЕРМОСТАТА КОМНАТНОЙ ТЕМПЕРАТУРЫ ПОВЛЕЧЕТ ЗА СОБОЙ НЕПОДЛЕЖАЩЕЕ РЕМОНТУ ПОВРЕЖДЕНИЕ ЭЛЕКТРОННОЙ ПЛАТЫ. При подключении регуляторов комнатной температуры с повременной...
  • Page 387 FORCE W Максимально допустимые нагрузки: • Циркуляционный насос отопления: 230 В пер. тока, макс. 0,8 A = 0,6 • 3-ходовой клапан: 230 В пер. тока, макс. 0,8 A = 0,6 в течение максимум 1 минуты, 0,4 A постоянно • Тревога: 230 В пер. тока, макс. 0,8 A = 0,6 Для...
  • Page 388 FORCE W Каскадное подключение генераторов: прямой контур отопления и контур ГВС с циркуляционным насосом Принципиальная схема Электроника котла может управлять максимум 6 модулями. В примере приведены 3 модуля. рис. 54 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 389 FORCE W Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа. 300M 300S 9 10 11 12 13 14 15 16 17 18...
  • Page 390 тока. «Дополнительные схемы каскадных, гидравлических и электрических подключений вы можете найти на сайте www.ferroli.com в разделе, посвященном продукции для ЖИЛОГО СЕКТОРА, котлам, FORCE W а также загрузить техническую документацию, содержащую все характеристики установки и конфигурации, из папки РУКОВОДСТВА: РУКОВОДСТВО ДЛЯ РАЗРАБОТЧИКОВ ПРОФЕССИОНАЛЬНЫХ СИСТЕМ ОТОПЛЕНИЯ (CATALOGO RISCALDA- MENTO PROFESSIONALE_89CI3001_00_low.pdf)
  • Page 391: Дымоходы

    FORCE W 2.6 Дымоходы КОТЛЫ ДОЛЖНЫ УСТАНАВЛИВАТЬСЯ В ПОМЕЩЕНИЯХ, ОТВЕЧАЮЩИХ ОСНОВНЫМ ТРЕБОВАНИЯМ К ВЕНТИЛЯЦИИ. В ПРОТИВНОМ СЛУЧАЕ СУЩЕСТВУЕТ ОПАСНОСТЬ УДУШЬЯ ИЛИ ИНТОКСИКАЦИИ. ПРОЧИТАЙТЕ ИНСТРУКЦИИ ПО УСТАНОВКЕ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ ПЕРЕД УСТАНОВКОЙ АГРЕГАТА. СОБЛЮДАЙТЕ ТАКЖЕ УКАЗАНИЯ ПРОЕКТНОЙ ДОКУМЕНТАЦИИ. ПРИ ДАВЛЕНИИ ВНУТРИ ДЫМООТВОДНЫХ ТРУБ ВЫШЕ 200 ПА...
  • Page 392 ОГОЛОВОК Примеры расчетов FORCE W 60: имеющийся напор 77 Па 5 метров ТРУБЫ Ø80 + 3 КОЛЕНА Ø80 = (5 x 4,8) + (3 x 10)= 55<77 = OK 8 метров ТРУБЫ Ø80 + 6 КОЛЕН Ø80 = (8 x 4,8) + (6 x 10)= 100<77 = НЕТ...
  • Page 393: Подсоединение Трубы Для Слива Конденсата

    FORCE W Любые горизонтальные участки отвода дымовых газов должны иметь небольшой уклон в сторону котла, чтобы конденсат не вытекал наружу, вызывая капание. Перед выполнением монтажа проверьте по таблица 5, не будет ли превышена максимально допустимая длина дымохода, имея в виду, что каждому коаксиальному колену соответствует уменьшение длины в размере, указанном в следующей...
  • Page 394: Уход И Техническое Обслуживание

    выполняться только квалифицированным персоналом с подтвержденной квалификацией (отвечающим профессиональным техническим требованиям, предусмотренными действующим законодательством), например, персоналом региональной службы технической поддержки. FERROLI снимает с себя всякую ответственность за травмы и/или материальный ущерб, нанесенный в результате несанкционированного вмешательства в конструкцию агрегата со стороны неквалифицированных и неуполномоченных лиц. 3.1 Регулировки...
  • Page 395 FORCE W • Для моделей W 60 и W 80 Отвинтите винты “B” и снимите блок «Вентури/газовый клапан» (рис. 63). Отвинтите винты “E” и замените газовое сопло “F” на сопло из комплекта переоборудования, поместив его внутрь прокладки “G”. Соберите компоненты и проверьте уплотнения (рис. 64).
  • Page 396 FORCE W • Для моделей W 99, W 120 и W 150 Извлеките блок управления газовым клапаном (рис. 65). Отвинтите винты “C” (рис. 66), фиксирующие вентилятор, и извлеките блок (рис. 67). рис. 65 рис. 66 Отвинтите винты “E” и замените газовое сопло “F” на сопло из комплекта переоборудования, поместив его внутрь...
  • Page 397 FORCE W • Для всех моделей Измените параметр, относящийся к типу газа, выполняя следующие действия. Войдите в экранное окно, показанное на рис. 69, следуя по маршруту "МЕНЮ ПОЛЬЗОВАТЕЛЯ Техническое обслуживание Тестовый режим Выбор типа газа. Нажмите на контекстные клавиши 1 и 2, чтобы выбрать тип газа.
  • Page 398 FORCE W рис. 70- Максимальная регулировка моделей W 60 и W 80 рис. 71- Минимальная регулировка моделей W 60 и W 80 рис. 72- Максимальная и минимальная регулировка моделей W 99, W 120 и W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 399 FORCE W Активация тестового режима TEST Войдите в экранное окно, показанное на рис. 69, следуя по маршруту "МЕНЮ ПОЛЬЗОВАТЕЛЯ Техническое обслуживание Тестовый режим Тестовый режим”. Котел включается, постепенно достигая максимальной мощности отопления (Range Rated), которая задается в соответствии с указаниями из следующего параграфа.
  • Page 400 FORCE W МЕНЮ ТЕХНИКА ДОСТУП К СЕРВИСНОМУ МЕНЮ И ИЗМЕНЕНИЕ ПАРАМЕТРОВ ДОЛЖНЫ ВЫПОЛНЯТЬСЯ ТОЛЬКО КВАЛИФИЦИРОВАННЫМ ПЕРСОНАЛОМ. Доступ в меню «Техника» возможен только после ввода кода 4 1 8. Он действует в течение 15 минут. Меню «Параметры - Конфигурация» Доступно 16 параметров, обозначенных буквой “b”, которые не могут редактироваться с устройства дистанционного...
  • Page 401 FORCE W Параметр Описание Диапазон W 60 W 80 W 99 W 120 W 150 Минимальная температура виртуальной уставки 20-80°C Время ожидания отопления 0-10 минут Пост-циркуляция в режиме отопления 0-255 минут Режим работы насоса 0-3 Стратегия работы Мин. скорость насоса с регулируемой...
  • Page 402 FORCE W Меню «Параметры – Тип системы» Имеется 23 параметра, обозначенные буквой “P”; эти параметры не могут редактироваться с устройства дистанционного управления с таймером. Параметр Описание Диапазон W 60 W 80 W 99 W 120 W 150 0 = Нормальный запрос на отопление...
  • Page 403: Ввод В Эксплуатацию

    FORCE W 3.2 Ввод в эксплуатацию Контрольные операции, которые следует выполнять перед первым розжигом, а также после проведения технического обслуживания, во время которого котел отсоединялся от сетей питания, или работ на защитных устройствах или деталях котла: Перед включением котла •...
  • Page 404: Техническое Обслуживание

    FORCE W 3.3 Техническое обслуживание ПРЕДУПРЕЖДЕНИЯ И МЕРЫ ПРЕДОСТОРОЖНОСТИ ВСЕ ОПЕРАЦИИ ПО ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ ИЛИ ЗАМЕНЕ КОТЛА ДОЛЖНЫ ВЫПОЛНЯТЬСЯ СПЕЦИАЛИЗИРОВАННЫМ ПЕРСОНАЛОМ С ПОДТВЕРЖДЕННОЙ КВАЛИФИКАЦИЕЙ. Перед выполнением любых операций внутри котла отключите электропитание и закройте газовый вентиль, установленный перед котлом. В противном случае может возникнуть риск взрыва, электрического...
  • Page 405 FORCE W Открытие передней панели Некоторые компоненты внутри котла могут достигать высоких температур, и поэтому вызывать серьезные ожоги.Перед выполнением любых операций дождитесь, пока эти компоненты остынут, или наденьте подходящие перчатки. Чтобы снять кожух котла: 1. Отвинтите винты A (см. рис. 75).
  • Page 406 FORCE W Внеплановое техническое обслуживание и замена компонентов Замена электрода Чистка теплообменника cod. 3541V233 - Rev 00 - 06/2022...
  • Page 407: Устранение Неисправностей

    FORCE W 3.4 Устранение неисправностей Диагностика Котел оснащен современной системой самодиагностики. В случае сбоя в работе котла на дисплее появляется код неисправности, а в случае каскадного подключения - номер модуля. • Существуют неполадки, вызывающие постоянную блокировку, которую можно сбросить нажатием на секунду кнопки OK или...
  • Page 408 FORCE W Код неисправ Неисправность Возможная причина Способ устранения ности Индикация перегрева датчика отопления 1 (подача) Недостаточная циркуляция воды в системе Проверьте циркуляцию воды (отображается только в меню History) Индикация перегрева датчика на обратном трубопроводе Недостаточная циркуляция воды в системе...
  • Page 409 FORCE W Код неисправ Неисправность Возможная причина Способ устранения ности Защита при разнице Недостаточная циркуляция в котле Проверьте циркуляцию воды в котле/системе температур > 21° между датчиком в контуре подачи и Неправильное положение датчика в контуре подачи Проверьте целостность датчика...
  • Page 410: Характеристики И Технические Данные

    FORCE W 4. Характеристики и технические данные Обозначения cap. 4 "Характеристики и технические данные" Подвод газа - Ø 3/4" Подача в систему - Ø1" 1/2 Возврат из системы - Ø1" 1/2 Предохранительный клапан Вентилятор Циркуляционный насос системы отопления (не входит в поставку) Датчик...
  • Page 411: Размеры И Соединения

    FORCE W 4.1 Размеры и соединения рис. 76- Вид спереди рис. 77- Вид сбоку рис. 78- Вид сверху рис. 79- Вид снизу cod. 3541V233 - Rev 00 - 06/2022...
  • Page 412: Общий Вид

    FORCE W 4.2 Общий вид рис. 81- Общий вид, мод. FORCE W 99 и FORCE W 120 рис. 80- Общий вид, мод. FORCE W 60 и FORCE W 80 рис. 82- Общий вид, мод. FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 413: Гидравлический Контур

    FORCE W 4.3 Гидравлический контур рис. 83- Гидравлический контур cod. 3541V233 - Rev 00 - 06/2022...
  • Page 414: Таблица Технических Данных

    FORCE W 4.4 Таблица технических данных В правом столбце указывается сокращение, используемое на табличке с техническими данными. cod. 3541V233 - Rev 00 - 06/2022...
  • Page 415 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 416: Диаграммы

    FORCE W 4.5 Диаграммы Потеря нагрузки рис. 84- Диаграмма потери нагрузки для моделей FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 рис. 85- Диаграмма потери нагрузки для моделей FORCE W 150 Расход - м...
  • Page 417: Электрические Схемы

    FORCE W 4.6 Электрические схемы Спецификацию рисунков можно найти на page 410. ВНИМАНИЕ: Перед подключением комнатного термостата или пульта ДУ с таймером снимите перемычку на клеммной колодке. ВНИМАНИЕ: для подключения 3-ходового клапана (клеммы 13–14–15) см. схемы рис. 86 и рис. 87.
  • Page 418 FORCE W рис. 89- Электрическая схема моделей FORCE W 60 и FORCE W 80 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 419 FORCE W рис. 90- Электрическая схема моделей FORCE W 99, FORCE W 120 и FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 420 FORCE W • Należy uważnie przeczytać ostrzeżenia zawarte w niniejszej odpowiednimi kwalifikacjami zawodowymi i wyłącznie przy instrukcji, ponieważ zawiera ona ważne wskazówki użyciu oryginalnych części zamiennych Nieprzestrzeganie dotyczące bezpieczeństwa podczas montażu, eksploatacji i powyższych zaleceń może negatywnie wpłynąć na bezpiec- konserwacji.
  • Page 421 FORCE W 1 Instrukcja obsługi ........................ 422 1.1 Wprowadzenie............................ 422 1.2 Panel sterowania ..........................422 1.3 Zapłon i wyłączanie ..........................426 1.4 Regulacje ............................427 2 Instalacja..........................435 2.1 Zalecenia ogólne ..........................435 2.2 Miejsce instalacji ..........................435 2.3 Podłączenia hydrauliczne........................435 2.4 Podłączenie gazu ..........................
  • Page 422: Instrukcja Obsługi

    FORCE W to generator ciepła do ogrzewania, kondensacyjny z mieszaniem wstępnym, o wysokiej wydajności i bar- dzo niskiej emisji spalin, opalany gazem ziemnym (G20), gazem płynnym (G30-G31) i propanem-powietrzem (G230), wyposażony w mikroprocesorowy system sterowania.
  • Page 423 FORCE W Przyciski bezpośrednie Przyciski bezpośrednie (poz. 8, 9, 10 - wygląd 1) zawsze mają taką samą funkcję. Przyciski nawigacji/menu Przyciski nawigacji/menu (poz. 5, 6, 7, 11, 12, 13 - wygląd 1) służą do przechodzenia pomiędzy różnymi menu na pa- nelu sterowania.
  • Page 424 FORCE W KONSERWACJA Patrz wygląd 73 Tryb TEST Patrz wygląd 69 Tryb TEST Wybór rodzaju gazu Tryb test kaskadowy Patrz “Informacje serwisowe” on page 432 Informacje serwisowe Patrz “Data interwencji serwisowej” on page 432 Data interwencji serwisowej USTAWIENIA Patrz wygląd 8 Język...
  • Page 425 FORCE W Wyłączenie zasobnika (economy) Użytkownik może wyłączyć ogrzewanie / utrzymywa- nie temperatury w zasobniku. W razie wyłączenia ciepła woda użytkowa nie będzie dostępna. Użytkow- nik może wyłączyć zasobnik (tryb ECO) poprzez na- ciśnięcie przycisku eco / comfort (poz. 10 - wygląd 1).
  • Page 426: Zapłon I Wyłączanie

    FORCE W 1.3 Zapłon i wyłączanie Zapłon kotła Nacisnąć przycisk włączenia/wyłączenia (poz. 14 - wygląd 1). Po naciśnięciu przycisku kontekstowego 1 można wy- brać żądany język. Zatwierdzić wybór przyciskiem „OK”. Po naciśnięciu przycisku kontekstowego 3 można pr- zerwać tryb FH.
  • Page 427: Regulacje

    FORCE W Wyłączenie kotła Na ekranie głównym (Home) nacisnąć przycisk kon- Aby całkowicie odłączyć urządzenie od zasilania elek- tekstowy i potwierdzić przyciskiem trycznego, nacisnąć przycisk 14 wygląd 1. Gdy kocioł zostaje wyłączony, karta elektroniczna jest nadal zasilana elektrycznie. Wyłączone jest działanie instalacji c.w.u. (z zainsta- lowanym opcjonalnym zasobnikiem) oraz c.o.
  • Page 428 FORCE W Redukcja temperatury c.o. Wejść do menu „Temp Regulacja Redukcja”, aby CH setpoint reduction zmienić temperaturę w zakresie od minimum 0°C do maksimum 50°C. Potwierdzić przyciskiem OK. Parametr ten jest stosowany wyłącznie wte- dy, kiedy włączone jest programowanie cza- sowe.
  • Page 429 FORCE W Wybrać dzień (wygląd 17) lub przedział dni do zaprogramowania (wygląd 18), a następnie potwierdzenie za pomocą przycisku OK. Scheduler Set Scheduler Set Wednesday Monday Thursday Tuesday Friday Wednesday Saturday Thursday Sunday Friday Monday-Sunday Saturday Monday-Friday Sunday Saturday-Sunday Monday-Sunday...
  • Page 430 FORCE W Nacisnąć przycisk nawigacji 7 i za pomocą przycisków Scheduler Set kontekstowych 1 i 2 ustawić tryb pracy podczas pie- rwszego przedziału godzinowego (wygląd 21) 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Page 431 FORCE W Aby przywrócić program godzinowy do war- Scheduler Set tości fabrycznych, nacisnąć przycisk kon- tekstowy 3 w menu Program godzinowy Monday (wygląd 26) i potwierdzić przyciskiem OK. Tuesday Wednesdey Thursday Friday Saturday Sunday Monday-Sunday to confirm wygląd 26 Dwa programy godzinowe Ogrzewania i Ciepłej wody użytkowej są niezależne również w przypadku Pr- zywrócenia do wartości fabrycznej.
  • Page 432 FORCE W Temperatura ustawiona w menu „Temp. Regulacja Zabezpieczenie przed bakteriami legionelli” NIE powinna być wyższa niż maksymalna temperatura regulacji c.w.u, ustawiona za pomocą parametru P19 w MENU TECHNICZNYM. Jeśli w układzie zainstalowano pompę obiegową do obiegu wody podczas funkcji zabezpieczenia przed bakteriami legionelli, konieczne jest ustawienie parametru b08 na 1.
  • Page 433 FORCE W Krzywa kompensacji i przesunięcie /offset/ krzywej Wejść do menu Płynnej temperatury. Wyregulować OTC Curve 1 żądaną krzywą w zakresie od 1 do 10 w zależności od charakterystyki (wygląd 30) za pomocą parametru „Krzywa 1” i potwierdzić przyciskiem OK.
  • Page 434 FORCE W Temperatura Zewnętrzna Ogrzewanie WYŁ. Wejść do menu „Temp Zew. Ogrz. Wył.”, aby włączyć funkcję: pomiędzy 7°C a 30°C. Jeśli funkcja ta jest włączona, będzie ona zawsze wyłączała żądanie ogrzewania w sytuacji, kiedy temperatura zmier- zona przez sondę zewnętrzną jest wyższa od wartości zaprogramowanej.
  • Page 435: Instalacja

    FORCE W 2. Instalacja 2.1 Zalecenia ogólne INSTALACJA KOTŁA MUSI BYĆ WYKONYWANA WYŁĄCZNIE PRZEZ WYKWALIFIKOWANY PERSONEL, ZGOD- NIE Z WSZYSTKIMI INSTRUKCJAMI PODANYMI W NINIEJSZEJ INSTRUKCJI TECHNICZNEJ, PRZEPISAMI AK- TUALNEGO PRAWA, ZALECENIAMI NORM KRAJOWYCH I LOKALNYCH ORAZ PRZEPISAMI WŁAŚCIWEGO WYKONAWSTWA. 2.2 Miejsce instalacji Generator powinien być...
  • Page 436 FORCE W Pompa obiegowa wysokiej wydajności (opcja) Ustawienie fabryczne jest odpowiednie dla wszystkich instalacji; jednakże za pomocą przycisk wyboru prędkości (patrz poz. 1 na wygląd 33) można ustawić inną strategię działania w zależności od parametrów instalacji. wygląd 33 Przy normalnym funkcjonowaniu dioda LED świeci się na zielono W razie usterki dioda LED jest włączona/miga...
  • Page 437 FORCE W - Ustawienie zewnętrznego elementu sterowania Prędkość pompy zależy od sygnału zewnętrznego pochodzącego z centralki sterowania kotłem. PWM typ 1: Prędkość pompy jest regulowana w zależności od sygnału PWM. W razie przerwania przewodu pompa przyspiesza do maksymalnej liczby obrotów.
  • Page 438 FORCE W Charakterystyka wody w układzie Przed przystąpieniem do zainstalowania generatora FORCE W należy odpowiednio wyczyścić instalację (zarówno nową, jak i istniejącą), aby usunąć ewentualne pozostałości po instalacji, rozpuszczalniki, błoto i ogólne zanieczyszc- zenia, które mogą obniżać sprawność zabiegów z użyciem środków ochronnych. Stosować neutralne środki czyszczące, które nie są...
  • Page 439 FORCE W Zawsze sprawdzać stężenie produktu po każdym włączeniu, a także cyklicznie, co najmniej raz w roku. Przeprowadzenie kontroli zlecać wykwalifikowanemu se- rwisantowi z naszej sieci autoryzowanych serwisów technicznych. Tabela 2- Środki chemiczne wskazane jako odpowiednie i dostępne w naszej sieci Autoryzowanych Serwisów Technicznych...
  • Page 440 FORCE W System zabezpieczający przed zamarzaniem, płyny przeciwzamarzaniowe, dodatki i inhibitory Kocioł jest wyposażony w system zabezpieczenia przez zamarzaniem, który włącza kocioł w trybie centralnego ogr- zewania, gdy temperatura wody na zasilaniu instalacji spada poniżej 5°C. Urządzenie nie jest aktywne, jeśli odłączone jest zasilanie elektryczne oraz/lub gazowe.
  • Page 441 FORCE W Przykłady obwodów hydraulicznych W przykładach opisanych poniżej konieczne może MENU być sprawdzenie/modyfikacja niektórych parametrów. W tym celu należy wejść do menu serwisanta. USER Na ekranie głównym (Home) nacisnąć przycisk Menu główne (poz. 12 - wygląd 1). TECHNICIAN Wejść do menu „Serwisant”. W tym celu nacisnąć pr- zycisk kontekstowy 2 (poz.
  • Page 442 FORCE W Dwa bezpośrednie obwody ogrzewania - Schemat główny wygląd 39 - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale. Legenda (wygląd 39 i wygląd 40) 9 10 11 12 13 14 15 16 17 18 Termostat pokojowy strefy 1 (bezpośrednia)
  • Page 443 FORCE W - Parametry Każda instalacja wymaga innego ustawienia parametrów. Przeprowadzić poniższą procedurę. Menu „Rodzaj instalacji” Zmienić parametr P.01 w menu „Rodzaj instalacji” na 4. - Funkcjonalności opcjonalne Oprócz podłączeń elektrycznych przedstawionych na poprzednim rysunku (koniecznych przy tej konfiguracji instalacji) istnieją...
  • Page 444 FORCE W Obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z pompą obiegową - Schemat główny wygląd 42 - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale.
  • Page 445 FORCE W - Parametry Każda instalacja wymaga innego ustawienia parametrów. Przeprowadzić poniższą procedurę. Menu „Parametry - Konfiguracja” Sprawdzić/Zmienić parametr b02 w menu „Parametry transparentne” na 8. Sprawdzić/Zmienić parametr b08 w menu „Parametry transparentne” na 1. Sprawdzić/Zmienić parametr b04, b05 i b06 w menu „Parametry transparentne” odpowiednio do wartości podanych w tabeli *** 'Menu Parametry - Konfiguracja' on page 466 ***.
  • Page 446 FORCE W Obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z zaworem rozdzielczym (3- żyłowy) - Schemat główny Użyć zaworu rozdzielczego 3-żyłowego: - FAZA OTWARCIA 230V - FAZA ZAMKNIĘCIA 230V - NEUTRALNY o czasach przełączania (od całkowitego zamknięcia do całkowitego otwarcia) nie dłuższych niż 90 sekund.
  • Page 447 FORCE W Aby zarządzać płynna temperaturą, konieczne jest nabycie sondy zewnętrznej o numerze kat. 013018X0 W razie korzystania z sondy zasobnika (nie wchodzi w zakres dostawy) konieczne jest nabycie sondy NTC o numerze kat. 1KWMA11W (2 m) lub o numerze kat. 043005X0 (5 m) W razie korzystania z termostatu zasobnika (nie wchodzi w zakres dostawy) konieczne jest nabycie zestawu akcesoriów o numerze kat.
  • Page 448 FORCE W Dwa obwody ogrzewania mieszane, obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z pompą obiegową - Schemat główny Karta sterowania strefą FZ4B może zarządzać różnymi typologami instalacji. Poniżej przedstawiono jeden przykład. Użyć zaworu rozdzielczego 3-żyłowego: - FAZA OTWARCIA 230V - FAZA ZAMKNIĘCIA 230V...
  • Page 449 FORCE W - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...
  • Page 450 FORCE W Legenda (wygląd 48 i wygląd 49) 72a Termostat pokojowy strefy 1 (mieszana) B = NEUTRALNY 72b Termostat pokojowy strefy 2 (mieszana) C = FAZA ZAMKNIĘCIA 72c Termostat pokojowy strefy 3 (bezpośrednia) 317a Termostat bezpieczeństwa strefy 1 (mieszana) 130 Pompa obiegowa zasobnika 317b Termostat bezpieczeństwa strefy 2 (mieszana)
  • Page 451: Podłączenie Gazu

    FORCE W 2.4 Podłączenie gazu Przed podłączeniem gazu sprawdzić, czy urządzenie jest przystosowane do działania z dostępnym typem paliwa i dokładnie przeczyścić wszystkie rury ga- zowe instalacji, aby usunąć ewentualne pozostałości mogące negatywnie wpłynąć na pracę kotła. Gaz należy podłączyć do właściwego przyłącza (patrz wygląd 79) zgodnie z obowiązującymi przepisami, za pomocą...
  • Page 452 FORCE W Podłączając zdalne sterowanie czasowe lub wyłącznik czasowy (timer) należy unikać podłączania zasilania tych urządzeń do ich styków przerywających. Ich za- silanie należy wykonać poprzez bezpośrednie podłączenie do sieci lub do baterii, zależnie od typu urządzenia. Sonda zewnętrzna (opcja) Podłączyć...
  • Page 453 FORCE W W przypadku podłączenia kaskadowego UWAGA: Elektronika kotła może obsługiwać maksymalnie 6 modułów. 1. Podłączyć moduły w taki sposób, jak to pokazano na wygląd 53 (przykład z 3 modułami) wygląd 53- Podłączenie kaskadowe A Moduł 1 C Moduł 3 B Moduł...
  • Page 454 FORCE W Generatory ułożone kaskadowo: obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z pompą obiegową Schemat główny Elektronika kotła może obsługiwać maksymalnie 6 modułów. W przykładzie jest 3. wygląd 54 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 455 FORCE W Połączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale. 300M 300S 9 10 11 12 13 14 15 16 17 18 9 10 11 12 13 14 15 16 17 18...
  • Page 456 „Więcej schematów podłączenia kaskadowego, hydraulicznego i elektrycznego, można znaleźć na stronie www.ferro- li.com z zakładce poświęconej produktom dla mieszkań, kotłom, FORCE W, a także można pobrać z zakładki IN- STRUKCJE dokumenty techniczne, w których znajdują się wszystkie specyfikacje dotyczące instalacji i konfiguracji: PODRĘCZNIK PROJEKTANTA PROFESJONALNYCH INSTALACJI GRZEWCZYCH (KATALOG PROFE-...
  • Page 457: Przewód Spalin

    FORCE W 2.6 Przewód spalin KOCIOŁ MUSI BYĆ ZAINSTALOWANY W MIEJSCACH, KTÓRE SPEŁNIAJĄ PODSTAWOWE WYMAGANIA WENTYLACJI. W INNYM PRZYPADKU ISTNIEJE NIEBEZPIECZEŃSTWO UDUSZENIA LUB ZATRUCIA. PRZED INSTALACJĄ URZĄDZENIA NALEŻY PRZECZYTAĆ INSTRUKCJĘ IN- STALACJI I KONSERWACJI. NALEŻY RÓWNIEŻ PRZESTRZEGAĆ INSTRUKCJI KONSTRUKCYJNYCH. W PRZYPADKU CIŚNIENIA WEWNĄTRZ RUR SPALINOWYCH POWYŻEJ 200 Pa NALEŻY OBOWIĄZKOWO STOSOWAĆ...
  • Page 458 KOŃCÓWKA Przykłady obliczania FORCE W 60; dostępna wysokość ciśnienia 77 Pa 5 metrów RURY Ø80 + 3 KOLANKA Ø80 = (5 x 4,8) + (3 x 10)= 55<77 = OK 8 metrów RURY Ø80 + 6 KOLANEK Ø80 = (8 x 4,8) + (6 x 10)= 100<77 = OK Przewód spalin...
  • Page 459: Podłączenie Spustu Kondensatu

    FORCE W Wszelkie poziome odcinki odprowadzające spaliny muszą być lekko pochylone w kierunku kotła, aby zapobiec ewen- tualnemu wypływowi skroplin na zewnątrz, co będzie powodem skapywania kondensatu. Przed przystąpieniem do instalacji sprawdzić w tabela 5, czy nie jest przekroczona maksymalna dopuszczalna długość, pamiętając, że każde kolanko współosiowe powoduje redukcję...
  • Page 460: Serwis I Konserwacja

    (posiadający przewid- ziane przez obowiązującą normę zawodowe kompetencje techniczne) jak np. personel lokalnego serwisu technicznego. FERROLI nie ponosi żadnej odpowiedzialności za szkody majątkowe i/lub uszkodzenia cielesne powstałe na skutek inte- rwencji przy urządzeniu przez osoby bez kwalifikacji i upoważnienia.
  • Page 461 FORCE W • W przypadku modeli W 60 i W 80 Odkręcić śruby „B” i wyjąć podzespół „ Zwężka Venturiego/zawór gazu” (wygląd 63). Odkręcić śruby „E:, a następnie wymienić dyszę gazu „F: na dyszę dołączoną w zestawie przezbrojeniowym. Umieścić dyszę w uszczelce „G”. Zamontować z powrotem komponenty i sprawdzić szczelność (wygląd 64).
  • Page 462 FORCE W • W przypadku modeli W 99, W 120 i W 150 Wyjąć centralkę zaworu gazowego (wygląd 65). Odkręcić śruby „C” (wygląd 66), które mocują wentylator, i wyjąć zespół (wygląd 67). wygląd 65 wygląd 66 Odkręcić śruby „E:, a następnie wymienić dyszę gazu „F: na dyszę dołączoną w zestawie przezbrojeniowym.
  • Page 463 FORCE W • We wszystkich modelach Zmienić parametr rodzaju gazu zgodnie z opisem poniżej. Przejść na stronę przedstawioną na wygląd 69 poruszając się w menu ścieżką „MENU UŻYTKOWNIKA Kon- serwacja Tryb testowy Wybór rodzaju gazu”. Nacisnąć przyciski kontekstowe 1 i 2, aby wybrać rodzaj gazu.
  • Page 464 FORCE W wygląd 70- Regulacja maksymalna modeli W 60 i W 80 wygląd 71- Regulacja minimalna modeli W 60 i W 80 wygląd 72- Regulacja maksymalna i minimalna modeli W 99, W 120 i W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 465 FORCE W Uruchomienie trybu TEST Wejść na ekran przedstawiony na wygląd 73, W tym celu przejść w menu ścieżkę „MENU UŻYTKOWNIKA Konse- rwacja Tryb TEST Tryb test”. Kocioł włącza się po osiągnięciu maksymalnej mocy ogrzewania (Range Rated) ustawionej zgodnie z opisem w następ- nym rozdziale w sposób stopniowy.
  • Page 466 FORCE W Wykres regulacji obciążenia cieplnego A = kW - B = Parametr karty elektronicznej wygląd 74 MENU SERWISANTA JEDYNIE WYKWALIFIKOWANY PERSONEL MOŻE UZYSKAĆ DOSTĘP DO MENU SERWISOWEGO ORAZ ZMIE- NIAĆ PARAMETRY. Dostęp do Menu Serwisanta jest możliwe dopiero po wpisaniu kodu 4 1 8. Jest ważne przez 15 minut.
  • Page 467 FORCE W Parametr Opis Zakres W 60 W 80 W 99 W 120 W 150 OFF=Wyłączony Czujnik spalin ON (Wł.) ON (Wł.) ON (Wł.) ON (Wł.) ON (Wł.) ON=Włączony Nie wprowadzono Maksymalna temperatury 0-125 °C spalin Wybór typu wentylatora Czas działania zabezpiecze-...
  • Page 468 FORCE W Parametr Opis Zakres W 60 W 80 W 99 W 120 W 150 Przy B02 = 7 - Niewykorzystane Przy B02 = 8 - Zabezpieczenie przed bakteriami legionelli WŁ. - WYŁ. WYŁ. WYŁ. WYŁ. WYŁ. WYŁ. Przy B02 = 9 - Zabezpieczenie przed bakteriami legionelli WŁ.
  • Page 469: Uruchamianie

    FORCE W Parametr Opis Zakres W 60 W 80 W 99 W 120 W 150 0-10Vdc Temperatura maksymalna (Sterowanie P.16 0 ÷ 100°C wg temperatury)** 0-10Vdc Napięcie ogrzewania WYŁ. (Sterowanie P.17 0,1-10 Vdc wg mocy)** 0-10Vdc Napięcie ogrzewania WŁ. (Sterowanie P.18...
  • Page 470: Konserwacja

    FORCE W • Przy pomocy analizatora spalania podłączonego do wyjścia spalin z kotła sprawdzić, czy zawartość procentowa w spalinach, przy kotle pracującym z maksymalną i minimalną mocą, odpowiada danym podanym w tabeli danych technicznych dla danego rodzaju gazu. • Upewnić się, że zużycie paliwa wskazywane przez licznik odpowiada podanemu w tabeli danych technicznych w sez.
  • Page 471 FORCE W Otwarcie panelu przedniego Niektóre komponenty wewnętrzne kotła mogą osiągać wysokie temperatury, które grożą poważnymi oparzeniami. Przed wykonaniem jakiejkolwiek czyn- ności należy odczekać, aż komponenty te ostygną lub ewentualnie założyć odpowiednie rękawice. Aby otworzyć obudowę kotła: 1. Odkręcić śruby A (patrz wygląd 75).
  • Page 472 FORCE W Konserwacja nadzwyczajna oraz wymiana komponentów Wymiana elektrody Czyszczenie wymiennika cod. 3541V233 - Rev 00 - 06/2022...
  • Page 473: Rozwiązywanie Problemów

    FORCE W 3.4 Rozwiązywanie problemów Diagnostyka Kocioł jest wyposażony w zaawansowany system autodiagnostyczny. W razie nieprawidłowości w działaniu kotła na wyświetlaczu pojawi się kod usterki oraz - w przypadku połączenia kaskadowego - numer modułu. • Istnieją usterki, które powodują stałą blokadę. W celu przywrócenia pracy należy nacisnąć przycisk OK i przytrzy- mać...
  • Page 474 FORCE W Usterka Możliwa przyczyna Środki zaradcze usterki Uszkodzony czujnik Awaria czujnika powrotu Zwarcie oprzewodowania Sprawdzić oprzewodowanie lub wymienić czujnik Instalacja elektryczna odłączona Uszkodzony czujnik Awaria czujnika c.w.u. Zwarcie oprzewodowania Sprawdzić oprzewodowanie lub wymienić czujnik Instalacja elektryczna odłączona Uszkodzony czujnik...
  • Page 475: Parametry I Dane Techniczne

    FORCE W 4. Parametry i dane techniczne Legenda do rysunku cap. 4 "Parametry i dane techniczne" Wlot gazu - Ø 3/4” Czujnik bezpieczeństwa Zasilanie instalacji - Ø 1” 1/2 Złącze spustowe kondensatu Powrót z instalacji - Ø 1” 1/2 Zawór bezpieczeństwa...
  • Page 476: Wymiany I Złącza

    FORCE W 4.1 Wymiany i złącza wygląd 76- Widok z przodu wygląd 77- Widok z boku wygląd 78- Widok z góry wygląd 79- Widok od dołu cod. 3541V233 - Rev 00 - 06/2022...
  • Page 477: Widok Ogólny

    FORCE W 4.2 Widok ogólny wygląd 81- Widok ogólny mod. FORCE W 99 i FORCE W 120 wygląd 80- Widok ogólny mod. FORCE W 60 i FORCE W 80 wygląd 82- Widok ogólny mod. FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 478: Obwód Hydrauliczny

    FORCE W 4.3 Obwód hydrauliczny wygląd 83- Obwód hydrauliczny cod. 3541V233 - Rev 00 - 06/2022...
  • Page 479: Tabela Danych Technicznych

    FORCE W 4.4 Tabela danych technicznych W kolumnie prawej podane są skróty stosowane na tabliczce znamionowej. cod. 3541V233 - Rev 00 - 06/2022...
  • Page 480 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 481: Tabele Erp

    FORCE W 4.5 Tabele ErP cod. 3541V233 - Rev 00 - 06/2022...
  • Page 482 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 483 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 484 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 485 FORCE W cod. 3541V233 - Rev 00 - 06/2022...
  • Page 486: Wykresy

    4.6 Wykresy Straty ciśnienia wygląd 84- Wykres strat ciśnienia w modelach FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 wygląd 85- Wykres strat ciśnienia w modelach FORCE W 150 Natężenie przepływu - m...
  • Page 487: Schematy Elektryczne

    FORCE W 4.7 Schematy elektryczne Legenda do rysunków znajduje się na page 475. WAŻNE: Przed podłączeniem termostatu pokojowego lub zdalnego panelu pokojowego zdjąć mostek w skrzyn- ce zaciskowej. UWAGA: W przypadku podłączania zaworu 3-drożnego (zaciski 13 - 14 - 15) postępować zgodnie z zaleceniami podanymi na schematach wygląd 86 i wygląd 87.
  • Page 488 FORCE W wygląd 89- Schemat elektryczny modeli FORCE W 60 oraz FORCE W 80 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 489 FORCE W wygląd 90- Schemat elektryczny modeli FORCE W 99, FORCE W 120 oraz FORCE W 150 cod. 3541V233 - Rev 00 - 06/2022...
  • Page 492 Fabbricato in Italia - Fabricado en Italia - Организация, уполномоченная производителем на принятие претензий от потребителя: ИЗАО "ФерролиБел". УНП 690655161. Адрес: улица Заводская, дом 45, город Фаниполь, Дзержинский район, Минская область, Республика Беларусь, 222750. Телефон: +375 (17) 169-79-49, адрес электронной почты: ferroli@ferroli.by.

Table des Matières