2.1.9.
MODEL SUIZA
STAINLESS KIT PLACEMENT (OPTIONAL)
In the case of optionally purchasing a STAINLESS KIT for Suiza model, you must follow the following steps to place the kit parts:
-
First, you must extract the oven tray, remove all refractory bricks as well as the existing metallic tube at the base of the oven.
-
Subsequently, you must extract the metal guides from the sides (see drawing D2.44).
-
For the placement of the new Kit, you must respect the following order: First place the guide on the left, then the rear performing the
connection of both pieces according to the detail image (see drawing D2.45):
-
Subsequently, the stainless ceiling must be placed, as shown in the image and anchor it to the left lateral guide in the existing
positioners (see drawing D2.46):
-
Finally, introduce the right lateral guide as indicated, so that ceiling is fitted on the two positioners of the guide (see drawing D2.47):
2.1.10.
BOMBAY SERIES
EXTERNAL AIR INTAKE
•
The models of the Bombay series have the possibility to choose that the primary air inlet comes from an adjacent environment or even from
the outside of the house.
In the case of providing air from outside or from an adjacent environment, you must purchase the optional kit (KIT-AIR4) of external air intake
(hermetic), it is enough to connect this KIT with a conduction of 120mm of diameter with the chosen place. Keep in mind that too long or
too many deviations (elbows), is far from benefiting the air intake, it causes a large loss of air feeding and therefore can cause combustion
problems.
The procedure for fitting the optional external air intake kit is as follows:
-
Remove the lower rear plate from the stove (see drawing D2.48).
-
Place the kit under the fire plane. You must center the kit and position it centered to the drawer as shown in the image.
-
Suspend the kit on the four
screws on the sides of the stove
drawer, so that the kit is fixed to
the stove (see drawing D2.49).
-
Connect the air intake to the
chosen exterior or environment
by using a 120 mm diameter
pipe.
-
Replace the rear plate of the
stove (see drawing D2.50).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
D2.44
D2.46
D2.48
27
D2.43
D2.47
D2.49
D2.45
D2.50
STOVES