NOTES:
When operating the air conditioner in low outside temperature,
be sure to follow the instruction described below:
•
Never install the outdoor unit in a place where its air inlet/outlet side may be exposed directly to
wind.
•
To prevent exposure to wind, install the outdoor unit with its air inlet side facing the wall.
•
To prevent exposure to wind, it is recommended to install a baffle board on the air outlet side of the
outdoor unit.
4.3 Drain Connection and Condensate Hose Installation
Install Drain Connection and Condensate Hose
•
The condensate water may drain from the outdoor unit when the unit operates in heating mode. In
order to avoid disturbing neighbors and protect the environment, it is necessary to install a drain
connection and a condensate hose to drain out the condensate water. (30~48K: Plugs and drain
connection are optional parts.)
•
Please do the drainage work before the indoor unit and outdoor unit are connected. Otherwise, it will
be difficult to install drain connection after the machine becomes immovable.
•
Connect the condensate hose (field-supplied) as shown in the figure for drainage.
NOTE:
•
Do not use the drain connection in a cold region. Drain may freeze to stop the fan runs.
4. Installation Instructions
-13-