Télécharger Imprimer la page

Ingeteam SMART DLM Manuel D'installation Et Configuration page 21

Publicité

Les langues disponibles

Les langues disponibles

SMART DLM
6. Use the joystick to scroll to the SYS system
selection screen. Press the joystick once
(PRG will appear at the bottom of the
display). Move the joystick in any of the 4
directions until you come to 1P (for single
phase installations) or 3P.N (for three-
phase installations). Press the joystick
once to accept
7. For the A65+ wattmeter, scroll to the CT
RATIO transformer ratio selection screen.
For example, if the transformer primary
current is 3000 A and the secondary
current is 5 A, then the transformer ratio is
600
8. Use the joystick to scroll to the ADDRESS
node number screen. Press the joystick
once (PRG will appear at the bottom of the
display). Move the joystick in any of the 4
directions to indicate the wattmeter node
number. This number must be the same as
the one indicated on the charging point that
will be communicating with the wattmeter.
(This number can be changed through the
webmanager.
Further
available
in
configuration manual). By default select
node number 1. Press the joystick once to
accept
9. This gives you access to the BAUD RATE
configuration screen. Press the joystick
once (PRG will appear at the bottom of the
display). Move the joystick in any of the 4
directions to select9600 bps. Press the
joystick once to accept