For continuous drip irrigation:
If the low quantity programme is to be used for more than 60 minutes,
the irrigation must be disrupted for at least 5 minutes before the end of
the 60 minute period. The low quantity programme can then be used
for a further 60 minutes.
4. MAINTENANCE
DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you maintain
the product.
To clean the filter [ Fig. M1 / M2 ]:
1. If applicable, close all the shutoff devices on the intake side.
(9)
2. Loosen the lid
of the filter chamber with the spanner
3. Remove the filter unit
(12)
/
(13)
(12)
4. Hold the cup
firmly, turn the filter
remove the filter 2 (bayonet fitting).
5. Clean the cup
(12)
under running water and clean the filter
e. g. with a soft brush.
6. Assemble the filter again in reverse order.
7. Start the pump (see 3. OPERATION).
To clean the check valve [ Fig. M3 / M4 ]:
CAUTION!
The pump must not be operated without the check valve.
1. If applicable, close all the shut-off devices on the intake side.
2. Open all tapping points so that the pressure escapes on the pressure
side. Now close the tapping points again so that the connected pipes
do not drain via the pump.
(14)
3. Loosen the cover
of the check valve with a suitable tool.
4. Remove the check valve
(15)
5. Assemble the check valve
6. Start the pump (see 3. OPERATION).
5. STORAGE
To put into storage [ Fig. S1 ]:
The product must be stored away from children.
1. Push the on / off switch
(11)
2. Disconnect the pump from the mains.
3. Open the consumer on the pressure side.
4. Remove the connected hoses on the pressure and suction side.
5. Unscrew drain bolt
(1)
.
6. Tilt the pump to the suction and pressure side until water is no longer
discharged from either side.
7. Store the pump in a dry, enclosed and frost-free place.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household
waste. It must be disposed of in line with local environmental
regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling collection
centre.
6. TROUBLESHOOTING
DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you
troubleshoot the product.
GAR_01757-20.960.11_2024-06-26.indd 11
GAR_01757-20.960.11_2024-06-26.indd 11
(A)
provided.
vertically upwards.
(13)
counterclockwise 1 and
(13)
and clean it under running water.
(15)
again in reverse order.
to position 0.
To troubleshoot with the error diagnosis system [ Fig. T1 ]:
The pump is equipped with an error diagnosis system which indicates
various error states via the error LED
1. Disconnect the pump from the mains.
2. Make the respective remedies from the table below.
3. Start the pump again.
The error display has been cleared and the pump is ready for operation
again.
Problem
Possible Cause
Error-LED flashes 1 time
The pump does not pump water for 30 seconds during the
initial operation.
(with a 2 second break)
Pump does not suck water
Pump was not sufficiently
filled with liquid to be pumped.
Air cannot escape on the pres­
sure side, because the pressure
side outlets are closed.
Pump does not start
The pump housing has heated
up and the thermal circuit brea­
ker has been activated.
The impeller is blocked.
Only for Art. 1758:
The flow sensor is dirty.
Flow sensor signal is faulty
Error-LED flashes
The pump does not pump water for 6 minutes during the
2 times (with a 2 second
initial operation.
break)
Pump does not suck water
Problem on the suction side.
Suction hose deformed
or bent.
Pump does not start
The thermal circuit breaker
has been activated
(motor overheated).
Error-LED flashes
The pump does not pump water for 30 seconds during the
3 times (with a 2 second
current operation.
break)
Water supply disrupted
Problem on the suction side.
on the suction side
Suction hose deformed or bent. v Use a new suction hose.
Pump does not start
The thermal circuit breaker
has been activated
(motor overheated).
Only for Art. 1758:
The flow sensor is dirty.
Flow sensor signal is
faulty
(e)
.
Remedy
v Fill the pump and make sure
that water does not drain out
on the pressure side during
the suctioning process
(see 3. OPERATION).
v Open the pressure side
outlets (see 3. OPERATION).
1. Open possible shut­off device
in the pressure line (release
pressure).
2. Ensure sufficient ventilation
and let the pump cool down
for 20 min.
1. Loosen the impeller (see
"To loosen the impeller").
2. Let the pump cool down for
20 min.
v Clean the flow sensor (see
"To clean the flow sensor").
v Immerse the suction hose
end under water.
v Eliminate any leak on the
suction side.
v Clean the check valve on
the suction line and check
the installation direction.
v Clean the suction filter on the
suction hose end.
v Clean the filter lid seal and
turn the lid until the stopper
(see 4. MAINTENANCE),
v Clean the filter in the pump.
v Use a new suction hose.
v Let the pump cool down
for 20 min.
v Immerse the suction hose
end under water.
v Eliminate any leak on the
suction side.
v Clean the check valve on
the suction line and check
the installation direction.
v Clean the suction filter on the
suction hose end.
v Clean the filter lid seal and
turn the lid until the stopper
(see 4. MAINTENANCE),
v Clean the filter in the pump.
v Let the pump cool down for
20 min.
v Clean the flow sensor (see
"To clean the flow sensor").