Télécharger Imprimer la page

Interpump Group KTR Serie Manuel D'utilisation Et D'entretien page 42

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 46
18
SPECIAL VERSIONS
The KT pump is also available in the special version:
KTR
The following information is helpful in deciding how to
choose and use this version.
Unless specified otherwise, observe the above instructions for
the standard KT pump.
18.1
KTR Pump
18.1.1
Operating instructions
The KTR series pump has been designed to operate
in environments with atmospheres that are not
potentially explosive and for using water rich in
particulate, therefore it is considered ideal for
systems with fluid recirculation.
The durability of the piston seals is directly in
relation to the percentage of the presence of solids
in the fluid as regards both their size and their
density.
For a long seal life we recommend a particulate
grain size of no more than 200 micron and 20% max.
in volume.
For more information and a general system layout,
see par. 9.7.
18.1.5
Technical characteristics
Model
Rpm
1450
KTR 28
1750
KTR 32
1450
KTR 40
1450
18.1.6
Dimensions and weight
For KTR version pump dimensions and weight, refer to Fig. 16.
Dry weight: 37.5 Kg (KT36-KT40)
42 Kg (KT36B-KT40B-W120120-W100140)
18.1.2
18.1.3
The rated specifications stated in our catalog are the
maximum that can be obtained by the pump. Independently
of the power used, the maximum pressure and rpm indicated
on the specification label can never be exceeded unless
prior formal authorization is given by our Technical Office or
Customer Service Department.
18.1.4
The minimum permissible speed of the crankshaft for these
types of pumps is 100 rpm; any rpm other than as shown in
the performance table (see par. 18.1.5) must be expressly and
formally authorized by the Technical or Customer Service
Department.
Flow rate
l/min
Gpm
69.6
18.40
84.0
22.20
91.0
24.0
142.0
37.50
42
Water temperature
The maximum permissible water temperature is
40°C. However, the pump can be used with water up
to a temperature of 60°C, but only for short periods.
In this case, it is best to consult the Technical Office
or Customer Service Department.
Maximum pressure and flow rate
Minimum operating speed
Pressure
bar
psi
200
2900
26.6
175
2538
28.0
150
2175
26.0
100
1450
27.0
Power
kW
HP
36.2
38.2
35.4
36.9
Fig. 16

Publicité