Operating Instructions SATAjet 3000 K spray mix
Note:
- Micrometer in vertical position (position III - parallel to the gun body) =
maximum atomization and maximum internal spray gun pressure (identical
with spray gun inlet pressure)
- Position I or II (across gun body) = minimum atomization, minimum internal
spray gun pressure (for spot repair, speckling etc.)
Attention: While the spray gun is connected to the air supply, the air micro-
meter fixing screw, pos. 11, must not be removed. When the fixing screw is
removed, the spray gun must not be put into operation.
4.4 Correct adjustment of the dynamic inlet pressure
a) Spray gun with micrometer / gauge
Ensure sufficient pressure by means of the pressure regulator. Adjust the
recommended inlet pressure of 1,5 - 2,0 bar/22 - 29 psi at the micrometer.
Art. No. 27771
b) Spray gun equipped with compressed air control gauge
Adjust the pressure at the pressure regulator in a way that the spray gun
inlet pressure required for the respective gun model is obtained.
Art. No. 4002
c) Spray gun without gauge
In order to make a correct adjustment of the spray gun inlet pressure, as
otherwise measureable in a) to b), without a gauge, adjust a pressure of
about 9 psi higher per 10 m to inlet pressure to compensate the pressure
drop in the hose.