4. Putting into Operation
Before putting into operation, and especially after each cleaning and any repair work, check to see
that all screws and nuts are tight. This especially applies to the closing screw, the round/flat spray
control (pos. 5) and for the locking screw (pos. 11) of the air micrometer. The paint spray gun has
been treated with an anticorrosive agent before leaving the factory and must therefore be flushed
out thoroughly with thinner before use. For servicing/repair work of any kind, the system must be
devoid of pressure, i.e. disconnected from the air supply. Failure to respect this safety warning
may result in damage and injuries, even death at worst. SATA does not take any responsibility for
possible results of such failure.
Material connection:
a) Connect material hose of pressure pot, respectively pump to the spray gun.
b) Adjust requested atomisation pressure with pulled trigger. Then adjust material feed pressure
with pulled trigger. Please check spray pattern on paper or other suitable substrate and adjust
pressure accordingly, if necessary.
4.1 Clean Spray air
...best obtained by using a combi fine filter unit with integrated pressure
regulator, for rough spray pressure adjustment. Due to high pressure drop in
the air hose/coupling, the actual dynamic air pressure should be checked and
fine-adjusted at the spray gun air inlet.
Art. No. 92296
4.2 Suffi cient air volume
...obtained by an appropriate compressor, large air line diameters and, to
avoid too much pressure drop, an air hose with minimum 9 mm inner diameter
in antistatic and pressure-resistant version and free from substances affecting
the painting result. Blow out the air hose before attaching it to the air connec-
tion (G 1/4 ext.). The air hose must be pressure-resistant for min. 145 psi and
solvent-resistant. Total electric resistance: < 100 million Ohm.
Art. No. 53090 (Length 10m) - (non-resistant against petrol and oil)
4.3 Air micrometer
For maximum air flow, fully open integrated Micrometer, i.e. put into vertical
position III. By means of the variable adjustable air micrometer the internal
spray gun presure can be set directly at the gun. Connect the spray gun to
the air supply, pull the trigger and adjust the requested spray gun internal
pressure.