For best operation, adjust the set-point
and the tank pressure to the specific
needs of your installation (See Table 2).
NOTE: The pump is designed for use
with clean water.

Application Limits

Temperature of pumped liquid: from
+41°F To +122°F (+5°C to +50°C) in
compatibility with the pump materials.
Maximum ambient temperature: +104°F
(+40°C).
Max. operating pressure: 116 PSI.
Use of this pump in situations requiring
very low boost may result in cycling
of the pump or fluctuations in water
pressure.
Table 1.
Pos.
Description
1
Type of Pump
2
For Installation
3
Power Supply
4
Circuit Breaker
5
Rated Current
6
Maximum
Liquid
Temperature
7
Maximum Head 116 PSI

Transport and storage

On delivery, check that the pump has
not been damaged during transport; in
case of damage, notify the distributor
immediately.
Store the pump in a clean, dry area
protected from external contaminants
and mechanical damage.
Specification
Variable Speed
Booster
Indoors Only
230V/50-
60Hz/1Ph
15 Amp
5A
122°F (50°C)
Installation
This water pressure booster pump is
a system including pump, expansion
tank, and variable speed drive (VFD) that
boosts water pressure in a home water
system, maintaining a constant pre-set
pressure. The system will pump water at
a maximum water temperature of 122°F
(50°C) at up to 21 gallons per minute.
NOTICE: This pump is not to be used to
draw water from a cistern or other static
water source.
The motor varies in speed to maintain
constant pressure, boosting water
pressure to the pressure you program
using four stainless steel impellers. The
VFD with integrated electronic speed
control indicates pump status and
controls the motor for soft starts and
soft stops to minimize water hammer.
The VFD has integral dry run protection.
Engineered composite plastic and
stainless steel is used throughout for a
durable and corrosion-free pump. The
integral expansion tank allows booster
use without an external pressure tank.
UNPACKING AND
INSPECTION
NOTICE: Handle with care. Check items
received against packing list to be sure
that all equipment has been received.
Inspect for shipping damage. If found,
file claim with carrier immediately.
Follow local and/or national plumbing,
building and electrical codes when
installing the pump. Use rigid pipe when
installing this pump.
INSTALLATION
Install the pump in a well-ventilated
area. Relative humidity in the
environment must not exceed 50% at
4