could cause a steam explosion and can
scald anyone near. If you find the pump
running hot, turn it off and let it cool.
Never allow the pump to cavitate, as this
can cause internal damage to the pump.
Explosion hazard.
Pressure on the discharge side of the
pump must never exceed the maximum
operating pressure as shown on the
pump. See "Application Limits", Table 1.
The discharge pressure of the pump
equals the pressure produced by the
pump plus the pressure on the suction
side of the pump.
Make sure that the suction and
discharge shutoff valves are both open.
When the Intelliboost is connected to
the power supply it initializes. The green
LED will be ON and the Pentair logo
shows up on the display (Figure 3a). As
this initialization ends, the pump stops
and the display shows STOP (Figure 3b).
LINE
RUN
FAULT
MODE
A.
LINE
STOP
STOP
RUN
FAULT
MODE
B.
Figure 3
SET
ESC
SET
ESC
If you need to change the set-point, wait
for the initialization to complete and
then push the up
button (See Figure 7 and 8]. Hold down
the button until the desired set-point is
displayed.
Start the pump by pressing the ON/OFF
button (Figure 4).
LINE
RUN
FAULT
MODE
Figure 4
The pump starts and reaches the
pressure level set at the factory (default
is 60PSI). The RUN/FAULT LED will be
ON and showing green. If the system
pressure is equal to or higher than the
factory pressure setting, the pump will
be in stand-by mode (green LED ON),
ready to start if the pressure decreases.
The pump should start immediately
when the pressure drops below the
set-point and pressure should return
to the set-point and stay there. Do not
run the pump with the discharge shut-
off valve closed! If the system goes to
PROTECTION mode, refer to the "Quick
Troubleshooting Guide".
MAINTENANCE
Hazardous voltage.
Can shock, burn, or kill. Before doing
any work on the pump or the VFD,
disconnect all power from the VFD and
wait 5 minutes for the VFD capacitors to
7
or down
SET
ESC