OPERATION
FIG. 18
A
G
I
A - 120 Volt AC 20 A receptacles
B - 120/240 Volt AC 30 A receptacle
C - 120/240 Volt AC 50 A receptacle
D - Parallel operation outlets
E - ECO mode switch
F - Reset button
G - 20 A circuit breaker
STARTING THE ENGINE: PROPANE
DANGER
ways turn the propane tank valve to the fully closed
position if not running the generator on propane.
l Make sure the LPG/propane hose is correctly connected
to the generator and propane tank.
l Turn the fuel selector switch to propane operation. (See
Figure 16.)
l Fully open the valve on the propane tank.
l Be sure the ECO mode switch is in the OFF position.
l Place the battery switch in the ON position.
l Choose the starting method:
 •  R emoteStart: Push and hold the START button on the
remote start key fob for one second.
 •  P ush-ButtonStart:Push and hold the engine START/
STOP button for two seconds.
 •  R ecoil Start: Firmly grasp and pull the recoil handle
slowly until you feel increased resistance, then pull
rapidly.
NOTE: In extreme cold, manually close the choke by
moving it right toward the front handle of the generator.
B
C
U
H - Smart switch connector (not included)
I - 30 A circuit breaker
J - Ground terminal
K - Low oil LED
L - Overload LED
M - Output ready LED
N - Digital display
Fire and explosion hazard. Al-
D
O
P
N
K
L
M
H
E F
J
O - Service generator LED
P - Automatic shutoff LED
Q - Propane hose connection
R - Battery switch
S - Fuel selector switch
T - START/STOP button
U - 50 amp circuit breaker
NOTE: During Push-Button or Remote Start the engine will
automatically set the choke and begin the start sequence.
If the engine fails to start, the generator will attempt to start
the engine two more times.
STOPPING THE GENERATOR
See Figure 18.
l Remove any connected loads from the control panel
receptacles.
l Allow the generator to run at "no load" to reduce and
stabilize engine and alternator temperatures.
l Put the battery switch in the OFF (O) position to stop the
generator.
l Stop the flow of fuel.
•  For gasoline, close the fuel valve.
•  For propane, close the cylinder valve on the LP gas
cylinder.
l Disconnect the propane hose from the LP gas cylinder
and the generator.
To stop the unit quickly in an emergency:
l Put the battery switch in the OFF (O) position.
T
Q
S
English | 21