5
TECHNICAL SPECIFICATIONS
Part Number
Model
Input
Voltage
Maximal input current consumption
Efficiency
Automotive input fuse
Output
Number of battery bank
Input / output isolation
Total rated current (+/-7%)
Charging curve
Battery type
Boost voltage
Floating voltage
Regulation tolerance before output
diodes and fuse
Peak to peak ripple
Automotive output fuse
Environment
Cooling
Sound level
Operating temperature
Storage temperature
Relative humidity
Casing
Material
Dimensions (length, height, depth) /
Weight
Fixing center distance
Fixing screw (wall)
Protection factor
PCB protection
Standards
CE declaration of conformity
CE / EMC
CE / Security - Others
Protections
Options
Temperature probe
Communication
YPO12-24V/30A
12-24V/30A
from 10VDC to 16DC
70A
90% typical
4 x 30A/32V (F5 to F8) Ref. 297030
1
no, 0V common
30A
IU or IUoU through internal dip switches (Boost,
Absorption, Floating and Refresh – factory setting)
Lead sealed as factory setting - Other choices
through internal setting :
28,8VDC for Lead sealed battery (factory setting)
27,6VDC for Lead sealed battery (factory setting)
< 2% (at rated conditions)
< 2% (at rated conditions)
2 x 30A/32V (F1 and F2) Ref. 297030
Electric fan controlled in temperature and current
< 50dBa at 1m
From -10°C to +65°C, derating from 50°C. Above
65°C, automatic charger switch off, automatic restart
when temperature decreases
From -20°C to +70°C
up to 70% (95% without condensation)
Casing comprises 3 parts :
· Aluminium sink frame
· Thermoplastic body
· Aluminium clasp
236 x 198 x 96 mm / 2.2kg
219 x 155 mm
4 off M5 round head screws
IP22
Water-repellent varnish (marine environment)
Available on request
EN61204-3
EN60335-2-29.
- Against output polarity reversal by fuse rupture
(removable automotive type)
- Against short-cuircuit and surge
- Against abnormal overheating by cutting off the
charger (internal temperature probe - automatic
restart)
Output voltage compensation : -36mV/°C
CAN BUS interface
31