5.

TECHNICAL SPECIFICATIONS

Model
Input
Voltage
*Output power from 85 to 170Vac
Frequency
Current intensity 230/115VAC
Power factor
Efficiency
Input fuses
Output
Number of outputs
Total rated current (+/-7%) / Rated
power
Load curve
Type of batteries
Regulated and filtered output voltage
Regulation tolerance before
distributors and fuses
Peak-to-peak ripple and noise
Automotive output fuses mounted in
parallel in the BAT pole -
Environment
Operating temperature
Cooling
Relative humidity
Storage temperature
Casing
Material
Paintwork
Dimensions excluding cable gland
(length, height, depth) / Weight
Fixing centre distances
Fixing screw (wall)
Protection factor
Board protection
Standards
CE/EMC marking
CE/safety marking
Electrical protections
CPS3OEM/24-40
90%
5,7A/11,5A
2 x T15A/250V – 6,3x 32 (F1/F2)
3 separated outputs BAT D, BAT 1 and BAT 2 (integrated distributor)
Each output can be used on its own and supply the entire current.
40A/1140W
Type of charge selected using internal switch IU or IUoU
(Boost, Absorption, Floating – factory setting).
See selection wheel setting table. The chargers can operate on DC supply.
2 x 25A/32V (F3, F4)
Rated conditions : from - 10°C to + 65 °C
Controlled draft fan at 20% of the rated current of the charger
Up to 70% (95% with no condensation)
Protected with water-repellent varnish (marine environment)
NF EN61000-6-1, NF EN61000-6-2, NF EN61000-6-3, NF 61000-6-4
- Against leaking input surges by rupture of VDR (voltage-dependent resistor) (not
covered by warranty)
- Against output polarity reversals by rupture of fuses
- Against output short-circuits and surges
- Against abnormal overheating by cutting off the charger (internal temperature probe
90°C) – Automatic re-start
Against output surges (34V ±5% in 24V)
-
CPS3OEM-3M-DEB
From 85 to 265VCA single-phase*
From 47 to 65Hz
0,9 in rated conditions
> 80% in rated conditions
2 x 25A RIT/250V – 6,3x 32 (F1/F2)
See selection wheel setting table
< 2% (in rated conditions)
< 2% (in rated conditions )
-20°C to +70°C
Casing comprises :
steel frame and steel front cover
polycarbonate clasp
Grey, black matt epoxy coating
350 x 270,8 x 123mm / 7,8Kg
329 x 154mm
4 M5 round screws
IP22
NF EN60950, NF EN60335-2-29
CPS3OEM/24-60
75%
9A/14,5A
60A/1710W
3 x 25A/32V (F3, F4, F5)
27