5
TECHNICAL SPECIFICATIONS
Part Number
Model
recommended battery bank (Pb)
Input
Voltage
Maximum current
Nominal Power
Efficiency
Input fuses
Output
Number of battery banks
Rated current
Charging curve
Battery type
Boost voltage (default)
Floating voltage (default)
Regulation tolerance
Peak to peak ripple and noise
Automotive fuse
Environment
Cooling
Operating temperature
Storage temperature
Relative humidity
Casing
length, height, depth / Weight
Fixing center distance
Fixing screws (wall)
Protection factor
PCB protection
Standards
CE declaration of conformity
CE / EMC
CE / Security - Others
Protections
YPO12-60/MPPT
12V/60A
500-700Ah
10 -45V (until 72 cells )
65A
800W
3 * 25A /32V
60A
IU or IUoU through internal push-button or CAN-BUS (Boost,
Absorption, Floating and Refresh – factory setting)
Lead sealed as factory setting - Other choices through internal setting :
gel, AGM, Calcium Lead, Lithium, Stabilized power supply, etc.
14,4VDC
13,8VDC
3 x 25A/32V
From -20°C to +60°C, derating from 60°C. Above 65°Cswitch off
up to 70% (95% without condensation)
Water-repellent varnish (marine environment)
EN60335-2-29. Pending E-marking.
Polarity reversal, short-circuit ,abnormal overheating
96% typical
1
< 2% (at rated conditions)
< 2% (at rated conditions)
Natural (fanless)
From -40°C to +70°C
236 x 180 x 96 mm / 2,2kg
219 x 155 mm
4 off M5 round head screws
IP22
Available on request
EN61204-3
YPO24-30/MPPT
24V/30A
200-400Ah
10 -45V (until 72 cells)
65A
800W
3 * 25A /32V
30A
28,8VDC
27,6VDC
2 x 25A/32V
40