1.2 WARRANTY
The manufacturer disclaims the warranty and CRISTEC waives any liability whatsoever if the installation rules and
instructions for use are not observed.
The warranty is valid for 36 months. It covers parts and labour for equipment returned to the Quimper plant. Only original
parts recognized as being defective will be replaced under the warranty.
Our warranty does not cover:
1 – Failure to abide by this manual
2 – Any mechanical, electrical or electronic alterations to the appliance
3 – Improper use
4 – Presence of moisture
5 – Failure to comply with power supply tolerances
6 – Incorrect connections
7 – Falls or impacts during transportation, installation or use
8 – Repairs carried out by anyone unauthorized by CRISTEC
9 – Connection of any interfaces not supplied by CRISTEC
10 – The cost of packaging ands carriage
11 – Apparent or latent damage sustained during shipment and/or handling (any such claims should be sent to the haulier)
Our warranty on no account provides for any form of compensation. CRISTEC shall not be held liable for damage
incurred as a result of using the battery charger.
2 TECHNICAL SPECIFICATIONS
Input
Voltage
Frequency
Current intensity 230/115VAC
Power factor
Efficiency
Input fuses F1/F2
Output
Number of outputs
Overall
rated
current
7%)/Rated power
Load curve
Type of batteries
Regulated and filtered output
voltage
Regulation tolerance before
distributor and fuses
Peak-to-peak ripple and noise
Automotive output fuses mounted
in parallel in the BAT pole -
Environment
Operating temperature
Cooling
Relative humidity
Case
Material
Paintwork
Dimensions excluding cable gland
(length, height, depth)/Weight
Fixing centre distances
Wall screw
CPS2OEM24V-40ADEB.DOC
From 85 to 265VAC, single-phase
De 47 to 63Hz
6A/12.6A
0.9 in rated conditions
> 80% in rated conditions
2 x 25A/250V – 6.3x 32
3 separate outputs BAT D, BAT 1 and BAT 2 (integrated distributor). Each output can be used
on its won and supply the entire current.
(+/-
40A/1140W
Type of charge selected using internal switch IU or IUoU (Boost, Absorption, Floating – factory
setting).
See switch settings table
See switch settings table. Chargers can operate on DC supply.
< 2%
< 500mV
2 x 20A/32V (F3/F4)
-10°C to +64°C ; +64°C to +70°C with 6% de-rating of rated Power/°C
Draft fan
Up to 70% (95% with no condensation)
Case comprises 3 parts: aluminium frame and steel flap and hood
Mat black, yellow, and grey epoxy coating
350 x 260 x 135mm / 7,5Kg
328,5 x 154mm
4 M5 round screws
15