5.
TECHNICAL SPECIFICATIONS
Model
Input
Voltage
Frequency
Current intensity 230/115VAC
Power factor
Efficiency
Input fuses
Output
Number of outputs
Total rated current (+/-7%) /
Rated power
Load curve
Type of batteries
Regulated and filtered output
voltage
Regulation tolerance before
distributors and fuses
Peak-to-peak ripple and noise
Automotive output fuses
mounted in parallel in the BAT
pole -
Environment
Operating temperature
Cooling
Relative humidity
Storage temperature
Casing
Material
Paintwork
Dimensions excluding cable
gland (length, height, depth) /
Weight
Fixing centre distances
Fixing screw (wall)
Protection factor
Board protection
Standards
CE/EMC marking
CE/safety marking
Electrical protections
CPS3OEM/12-25
1,8A/3,7A
2 x 6,3A/250V (F1/F2)
Réf, DEL MICRO FUSE
00346623MST
3 separated outputs BAT D, BAT 1 and BAT 2 (integrated distributor)
Each output can be used on its own and supply the entire current.
25A/356W
Type of charge selected using internal switch IU or IUoU (Boost, Absorption, Floating – factory setting).
See selection wheel setting table. The chargers can operate on DC supply.
1 x 30A/32V (F3)
Rated conditions : from - 10°C to + 55 °C; over, de-rating : reduction of the output power < than 2,5 %/°C
up to 65°C
Natural cooling
Casing comprises :
Casing comprises :
•
aluminium sink frame
•
•
steel front cover and
•
steel
cable
glands
mounting plate
polycarbonate clasp
•
and top
258,5 x 179 x 106mm /
2,5Kg
240 x 110 mm
IP23
Protected with water-repellent varnish (marine environment)
NF EN61000-6-1, NF EN61000-6-2, NF EN61000-6-3, NF 61000-6-4
-
Against leaking input surges by rupture of VDR (voltage-dependent resistor) (not covered by warranty)
-
Against output polarity reversals by rupture of fuses
-
Against output short-circuits and surges
-
Against abnormal overheating by cutting off the charger (internal temperature probe 90°C) – Automatic
re-start
Against output surges (17V ±5% in12V) (34V ±5% in 24V)
-
CPS3OEM-1M-2M-DEC
CPS3OEM/12-40
From 85 to 265VCA single-phase
From 47 to 65Hz
2,9A/5,9A
0,9 in rated conditions
> 80% in rated conditions
2 x T15A/250V – 6,3x 32 (F1/F2)
40A/570W
See selection wheel setting table
< 2% (in rated conditions)
< 2% (in rated conditions )
2 x 25A/32V (F3/F4)
Controlled draft fan at 20% of the rated current of the charger
Up to 70% (95% with no condensation)
-20°C to +70°C
steel frame and steel front cover
polycarbonate clasp
Grey, black matt epoxy coating
280 x 212 x 112mm / 4,6Kg
4 M5 round screws
NF EN60950, NF EN60335-2-29
CPS3OEM/24-20
CPS3OEM/12-60
2,8A/5,7A
20A/570W
1 x 25A/32V (F3)
3 x 25A/32V (F3/F4/F5)
266x 110mm
IP22
4,5A/9,1A
60A/855W
27