Test Record
Test Description
Voltage Programming & Readback
    Minimum voltage (Vout):
    Voltage measured over interface:
    High voltage (Vout):
    Voltage measured over interface:
CV Load Effect:
CV Ripple and Noise
    peak-to-peak:
    rms:
Transient response @ 300 µs:
Current Programming & Readback
    Minimum current (Iout):
    Current measured over interface:
    High current (Iout):
    Current measured over interface:
CC Load Effect:
Current Sink Tests
      10% of current rating:
Voltage Programming & Readback Min:
Voltage Programming & Readback High:
CV Load Effect:
CV Ripple and Noise*:
Transient Response:
Current Programming & Readback Min:
Current Programming & Readback High:
CC Load Effect:
10% of Current Rating (Isink):
*
Equipment damage. The LeCroy DXC100A probe is limited to 500 V. Only connect for CV Ripple and Noise test.
** Current comp 3 generates a 40 μs risetime step in the load list, which is required for the transient response test.
Keysight PV8900 Series Operating and Service Guide
Report Number ______
Min. Specs
1.8492
Vout - 0.1508
1999.05
Vout - 0.95
- 0.1
N/A
N/A
- 20
- 0.003
Iout - 0.003
29.988
Iout - 0.012
- 0.004
-3.06392
PV8922A UUT Settings
Voltage priority: 2 V, 5 A
Voltage priority: 2000 V, 5 A
Voltage priority: 666 V, 30.5 A
Voltage priority: 500 V, 30.5 A
Voltage priority: 666V, 30.5A, Comp 0
Current priority: 670 V, 0 A
Current priority: 670 V, 30 A
Current priority: 2040 V, 10 A
Voltage priority: 0 V, 0 A
6 Verification and Calibration
Date__________
Results
_______
_______
Vout + 0.1508
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
RP7973A or RP7983A Load Settings
not used
not used
Current priority: 670 V, -30 A
Current priority: 520 V, -30 A
Current priority: 1100 V, -12 A to -27 A, slew=max, Comp 3**
Voltage priority: 666 V, 0 A
Voltage priority: 666 V, -30.6 A
Voltage priority: 2000 V, -10.2 A
Voltage priority: 666 V, 30 A
Max. Specs
2.1508
2000.95
Vout + 0.95
+ 0.1
3
0.4
+ 20
0.003
Iout + 0.003
30.012
Iout + 0.012
+ 0.004
-3.05608
271