WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
LP Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Ensure that the manual shutoff valve is in the closed position
and the power supply cord is unplugged.
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
12
GAS CONVERSIONS
2. Remove storage drawer or warming drawer. Locate gas
pressure regulator at rear of storage or warming drawer
compartment.
NOTE: On models with a warming drawer, an access cover
must be removed from the gas pressure regulator.
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure regulator
3. Remove plastic cover from gas pressure regulator cap.
4. Turn gas pressure regulator cap counterclockwise with a
⁵⁄₈" combination wrench to remove.
NOTE: Do not remove the spring beneath the cap.
A
5. Turn over the gas pressure regulator cap and reinstall on
regulator so that the hollow end faces out and the marking
"<- LP" is facing the direction shown in the above drawing.
6. Replace plastic cover over gas pressure regulator cap.
B
C
A
A. Gas pressure regulator
Side view before
B
D
Side view after
C
A. Plastic cover
B. Gas pressure regulator cap with solid end facing out
C. Gas pressure regulator cap with hollow end facing out
D. Washer
E. Gas pressure regulator cap
E