Gas Conversions; Lp Gas Conversion - Whirlpool W10403810B Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
14

GAS CONVERSIONS

A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn the manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator (Natural Gas to
LP Gas)
1. Remove storage drawer or warming drawer. See the "Storage
2. Locate gas pressure regulator at rear of storage or warming

LP Gas Conversion

WARNING
Tip Over Hazard
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
Drawer" or "Warming Drawer or Premium Storage Drawer"
section.
drawer compartment.
NOTE: On models with a warming drawer, an access cover
must be removed to access the gas pressure regulator.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
B
C

Publicité

Table des Matières
loading

Table des Matières