Preparing the Installation Site
Survey the installation site. Take into account the need for
louvered or grill-style openings in the cabinetry to provide proper
ventilation for the unit as well as access to the control panel. One
of these ventilation openings must be in front of the condensing
coils with the other on the opposite side of the condensing coils.
If multiple refrigerated wells are installed in the same counter,
each unit must intake cool air and expel hot air.
NOTE: The condensing unit cannot be moved or rotated under
the well. Damage to the refrigerant tubing will occur.
The cabinet must be enclosed on all four sides. The condensing
unit must be isolated from other electronic devices using fully
sealed partitions. The cabinet must allow access for ventillation,
control access, and maintenance/cleaning access.
1. Cut the appropriate opening in the countertop for the unit
being installed. Refer to "Countertop Cutout Dimensions"
in this section.
2. If installing the control panel remotely, cut and drill the
appropriate holes in the vertical surface where the control
panel will be installed. Refer to the "Installing the Remote
Control Panel" procedure for cutout dimensions.
3. Cut opening in the cabinet for intake vent.
• The cutout must be 12" x 12" (31 x 31 cm).
• The opening for the intake must be no further than 5'
(1524 mm) from the condenser coils.
4. Cut opening in the cabinet for exhaust vent.
• The opening for the exhaust must be cut no more than
1" (25 mm) from cabinet floor.
• The opening should be a minimum of 12" x 12"
(31 x 31 cm) or 144 square inches (961 square cm).
• The opening for the exhaust must be located on the
opposite side of the condensing unit.
Cut out exhaust opening in
one of the white highlighted
areas when installing well
and condensing unit in this
orientation.
Countertop removed for clarity.
CWBPM-0524
5. Cut opening in the cabinet for access to the control panel,
if necessary. Refer to the "Installing the Control Panel
Remotely" procedure for the cutout dimensions.
6. Cut opening in the cabinet for access to the condensing
unit coils for cleaning. Louvered or grill-style panels should
be installed in the openings to protect the condensing unit.
7. Make structural modifications or add bracing underneath
the countertop to ensure the countertop will support the
weight of the unit and its contents. Make sure a minimum
7" (178 mm) clearance will be available between the
condensing unit and any interior surface.
NOTE: The countertop must be level to ensure proper draining
of the refrigerated well.
8. Make sure a grounded electrical receptacle of the correct
voltage, size, and plug configuration is within 6' (1829 mm)
of the mounting location for the control panel. See the
SPECIFICATIONS section for details.
FIRE HAZARD: All electrical receptacles must be at least
12" (305 mm) above the cabinet floor.
Installing the Unit
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
1. Lift the unit out of the shipping frame and carefully lower it
into the countertop cutout.This step requires two or more
people, depending on the unit.
2. Apply NSF-approved silicone sealant around the edge of
the unit to seal it to the countertop.
Condenser Coils
(inside duct collar)
Countertop Cutout
9
INSTALLATION
WARNING
NOTICE
Cut out the intake opening in one
of the gray highlighted areas when
installing well and condensing unit
in this orientation.
12" x 12"
cutout for
intake air.
...continued