Installation instructions, for professionals only
Set foil operating mode with temperature control
(only Pro D2i/Pro D3i)
Here you can specify that if the temperature control is set (see "Set operating
mode of auxiliary output-lr"on page 43 ), the auxiliary output remains in
temperature control mode even when the sauna heater is switched on.
1. Open the technician menu (see page 38).
2. Select "bIr" by pressing the mode button D.
3. Press the On/Off button A.
4. Select the desired value with the plus button B and the minus button C:
● "oFF": The additional output changes to intensity mode when the sauna
heater is switched on (standard; dimmable/switchable, see page 41)
● "on": The additional output always remains in temperature control
5. Confirm the selection by pressing the On/Off button A.
6. Make other settings or leave the technician menu by pressing the On/Off
button A for about 3 seconds.
7. Then switch the power unit off for about 10 seconds.
Querying the software version
To query the software version of your sauna control unit, carry out the follow-
ing steps:
1. Open the technician menu (see page 38).
2. Select "SOC" or "SOP" by pressing the mode button D.
● "SOC" displays the control panel software version (e.g. 132)
● "SOP" displays the power unit software version (e.g. 214)
3. Make other settings or leave the technician menu by pressing the On/Off
button A for about 3 seconds.
Exiting the technician menu
1. The technician menu is closed by pressing the On/Off button for about
3 seconds.
2. Then switch the power unit off for about 10 seconds. (see "Switching off
the power supply unit" on page 60).
p. 44/70