EN – Installation instructions
The radiator may only be installed by a speci-
alized tradesman.
The electric set may only be connected by an
electrical specialist (in Germany according to
BGV A3).
Safety instructions
Read these instructions for installation and use
W
thoroughly prior to installation/commissioning.
After installation pass the instructions on to
W
the end used.
Observe the safety directions in the separate
W
electric set instructions.
Danger
Life-threatening situation!
Check the condition of the supply lines (elec-
W
tricity, gas, water).
Do not drill into any lines.
W
Install and connect the device only in the de-
W
energized state.
Warning
Risk of injury!
Note the radiator's weight (see page 8).
W
At 25 kg and above, work with lifting equip-
W
ment or several persons.
Warning
Personal injury and material damage!
Check load-bearing capacity of installation
W
site. Take the radiator's filled weight (see
page 8) and possible additional loads into
consideration.
Check fasteners for applicability and tailor
W
them to the structural situation.
Special requirements, e.g. for public buil-
W
dings (schools or the like), must be taken
into account.
Operating conditions
Do not connect the radiator to the heating
W
system.
When installing in rooms with bath or shower
W
facilities: take into account protective areas
according to national installation standards
(in Germany DIN VDE 0100-701). Also follow
all local regulations.
Electrical equipment is permitted in the rooms
W
referred to above if it is protected by a residual
current protective device (RCD) (in Germany
according to DIN EN 61008-1 (VDE 0664-10)).
Sockets may only be installed outside safety
W
areas.
Note: the manufacturer does not approve the
W
installation of products in protective area 1.
Recommendation according to IEC stan-
W
dard 60335-2-43: To prevent any risk to
small children, install the radiator so that the
bottommost cross tubes are situated at least
600 mm above the floor.
When installing , provide an on-site residu-
W
al-current-operated protective device (with
trigger limit less than or equal to 30 mA).
4
If a device without a connector is directly con-
W
nected to the fixed electrical installations, in-
stall an isolator in accordance with the local
provisions for mains disconnection.
Operate the radiator only with the approved
W
voltage (see typeplate).
Store and transport radiator only in the pro-
W
tective foil.
Complaint
Contact the manufacturer.
W
Disposal
Packaging should be recycled or disposed of
W
properly. Observe local regulations.
Technical features
Electrical connection:
W
– Heating element pre-installed at bottom
right or left in the collector
– Connection via electric set
Test pressure: 8 bar
W
Fill: non-combustible, non-toxic heat transfer
W
liquid
Duty type: electrical operation, irrespective of
W
the heating system, with adjustment via elec-
tric set
Directions for installation
Number of attachment points
The number of attachments points was deter-
mined and checked on vertically cored light-
weight brick T14.
Set down radiators with a heating element in-
W
stalled in such a way that the element is not
damaged.
Do not fasten any cables to the radiator, do
W
not roll cables.
Ensure that a correctly installed mounting box
W
or wall socket (230 V, 16 A fuse) is available
within the reach of the cable.
The electrical connection at the wall must be
freely accessible and must not project out to the
surface of the radiator or the control unit.
The radiator must not be attached directly be-
neath a wall socket.
FR – Instructions d'utilisation
Utilisation conforme
Le radiateur doit être utilisé exclusivement pour
le chauffage d'espaces intérieurs et le séchage de
textiles ayant été lavés à l'eau.
Toute autre utilisation n'est pas conforme à
l'usage prévu et est donc interdite.
Utilisation non conforme
Le radiateur ne doit pas être utilisé en tant que
siège, échelle ou escabeau.
Consignes de sécurité
Advertissement
Danger de mort par électrocution !
Ne pas utiliser l'appareil si le câble de raccor-
W
dement est endommagé.
Si le câble de raccordement est endommagé,
W
il doit être remplacé par le fabricant, son ser-
vice après-vente ou une personne disposant
d'une qualification similaire.
Danger
Danger de mort !
En cas d'incendie, ne jamais éteindre avec
W
de l'eau.
Utiliser des extincteurs au gaz carbonique, à
W
mousse, à poudre ou du sable.
Advertissement
Risque de brûlure!
La surface du radiateur peut atteindre une tem-
pérature de 90 °C (194 °F).
Soyez prudent au toucher du radiateur.
W
L'appareil peut être utilisé par des per-
sonnes présentant un handicap phy-
sique, sensoriel et mental ou manquant
de connaissances et d'expérience ainsi
que par des enfants à partir de 8 ans
s'ils sont sous surveillance ou ont été
instruits sur une utilisation sécurisée de
l'appareil et s'ils comprennent les dan-
gers encourus.
Les enfants de moins de 3 ans doivent
être tenus à l'écart de l'appareil, à
moins de les surveiller en permanence.
Les enfants de plus de 3 ans et de
moins de 8 ans ne peuvent allumer et
éteindre l'appareil que si les conditions
antérieures sont respectées et dans la
mesure où l'appareil est installé ou situé
dans sa position habituelle de fonction-
nement.
Les enfants de plus de 3 ans et de
moins de 8 ans ne peuvent ni intro-
duire la fiche dans la prise, ni nettoyer
l'appareil, ni effectuer la maintenance
relevant de l'utilisateur.