Télécharger Imprimer la page

AUTOFRY MTI-5 Mode D'emploi page 26

Publicité

Les langues disponibles

Les langues disponibles

Safety System Test
The safety system must be tested at least every six months. A qualified equipment repair technician
following these instructions should perform this inspection.
These tests must be started with a full oil pot of clean, cool oil.
1.
Open the main door of the AutoFry and press POWER.
The keypad will display SAFETY SWITCH FRONT DOOR and the AutoFry will
continuously beep.
Remove each of the following components one at a time.
2.
Close the main door and press POWER.
The keypad will display SAFETY SWITCH and the
individual switch that is open.
3.
After verifying a switch go to the next one until you have verified
that all safety switches are working properly.
The AutoFry is equipped with an airflow switch which must be tested for
proper function.
1.
With the filters installed and the main door closed, press POWER on the keypad.
2.
Using a flat piece of cardboard or 1/4" plywood, completely block the exhaust flow at the fire
damper / stack cover.
The exhaust fan will operate for a short period. The switch will open due to the lack of
airflow and the keypad will display SAFETY SWITCH AIRFLOW.
If the oil is above 192°F the fan will continue to operate until the oil cools.
Cooking Oil Disposal
Cooking oil must be disposed of in accordance with national, state, and local regulations.
Included with this manual is a maintenance log to be signed and dated after the completion of daily,
weekly and quarterly maintenance and testing. Your local or state health and safety inspectors may
require this log to be posted in a noticeable location.
63-0132 MTI-5 TS OM 01/24
MTI-5 Operator's Manual
1. Filter Cover Plate
2. Grease Baffle
3. Second Filter
4. Charcoal Filter
5. Removable Fire Damper
AutoFry
24

Publicité

loading