7.
Install the Charcoal Filter.
Remove the filter cover plate from the back interior wall of the cooking chamber by
removing the two black plastic knobs securing the cover plate. Figure 4.
Remove the charcoal filter from the plastic bag. Insert it into the tracks above the second
filter. Figure 5.
Reinstall the filter cover plate and turn the
filter cover knobs clockwise until hand tight.
Verify the word TOP on the filter cover plate is
in the upper left hand corner. Figure 4.
Charcoal Filter
Second Filter
Drain Holes
Grease Baffle
Figure 5
8.
Sanitize the interior.
All interior surfaces must be sanitized.
9.
Install the Oil Pot.
Place the oil pot in the cooking chamber with the drain valve facing the front of the AutoFry.
The square legs of the oil pot will sit against the back wall. Ensure that the drain valve is in
the closed position.
63-0132 MTI-5 TS OM 01/24
AutoFry
MTI-5 Operator's Manual
Both the grease baffle and second filter have small
holes along one side of the frame.
These drain holes must be facing down for the
filters to efficiently drain and clean the air. Figure 5.
Closed
8
"TOP"
Filter Cover Knobs
Figure 4
Drain Valve