Télécharger Imprimer la page

AUTOFRY MTI-5 Mode D'emploi page 25

Publicité

Les langues disponibles

Les langues disponibles

AutoFry
MTI-5 Operator's Manual
IMPORTANT
Charcoal Filter
In order for the AutoFry to continue to perform as a ventless cooking appliance the activated charcoal
filter MUST be changed at least every three months. This maintenance is required by your equipment
warranty and requirements for ventless re-circulating cooking appliances.
While replacing the activated charcoal filter is easy, there will be some charcoal dust present. Replacing
the charcoal filter should be performed away from your food preparation areas.
Remove the used activated charcoal filter and replace with a new one.
Use replacement charcoal filters supplied by AutoFry. Filters can be ordered by calling 1-800-348-2976
x.1154 or at
www.AutoFryWebStore.com.
Second Filter
The second filter MUST be changed at least every six months. Heavy usage may require that the second
filter be changed more frequently. If it appears the second filter can no longer be cleaned effectively then
it should be replaced. Second filters can be ordered by calling 1-800-348-2976 x.1154 or at
www.AutoFryWebStore.com.
Semi-Annual Cleaning and Maintenance
Fire Suppression System
IMPORTANT
An Inspection of the fire suppression system must be performed every six months in order to comply with
NFPA 96, NFPA 17A and UL 710B. A certified fire equipment maintenance company must perform this
inspection.
Consult your fire suppression manual that has been supplied with the AutoFry for details on the inspection
and re-charge instructions.
The fusible links and s-hooks located in the cook chamber and exhaust stack must be replaced semi-
annually.
WHEN REPLACING FUSIBLE LINKS, YOU MUST USE
THE SAME RATED LINKS OR THE FIRE SUPPRESSION
SYSTEM MAY NOT WORK AS DESIGNED!
COOKING CHAMBER: 280°K Fusible Link
FIRE DAMPER: 212°J Fusible Link