Activated Pump
MOP wash
Micro fibre wash
Micro fibre wash
Desinfection
Desinfection
Desinfection
Description of the inlet valves:
P1: Is activated during pre-wash, the first four seconds of the
main wash, the cool down sequences (at selected temp over
60°C) and during the rinses.
P2: If hot water is connected, this valve will also be activated
when the inlet water is warmer than the selected temperature (or
selected temperatures below 40°C).
P3: Hot water valve is activated during the main wash if hot wa-
ter is selected, and the selected temperature is over 30°C.
Clean cycle:
Every 10th program a clean cycle is activated during the main
wash. Inlet Valve 1 is activated for 8 seconds and Inlet Valve 2
for 8 seconds.
Procedure:
1. Push out or drill the appropriate amount of knock-out holes in
the rear panel. Hole size should be Ø 21mm.
2. Mount the grommet nuts in the holes.
3. Separate the cables coming from the control unit at the inlet
valves.
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Main wash
Pre-
Warm water
wash
connected
P1
P2
1
3 or 3+2
3 or 3+2
3 or 3+2
1
3 or 3+2
1
3 or 3+2
1
3 or 3+2
Cold water
connected
Rinse
P2
P1
2
1
2
1
2
1
2
1
2
1
2
1
4. Mount the cables for the inlet valves in the relay board. Do
this according to color-coding on the connectors.
5. Place the card on the left side of the back panel.
4
Rinse
Rinse
Rinse
P1
P1
P1
1
1
1
1
1
Figure 8
Figure 9
Form No. 6-15-274ENR1
Last
Rinse
P3
1+2
1+2
1+2
1+2
1+2
1+2