Modbus RS485.
•
Large LAN and WAN-based computer systems often require
that communication with any element that is integrated into
the computer network be carried out via a standard industry
protocol.
One of the most widely used standard industry protocols on
the market is the MODBUS protocol.
Relay interface.
•
The UPS has, as an option, a relay interface card that
provides digital signals in the form of potential-free
contacts, with a maximum applicable voltage and current
of 240 V AC or 30 V DC and 1 A.
This communication port allows dialogue between the
device and other machines or devices through the relays
supplied in the terminal block arranged on the same card,
with a single common terminal for all of them.
From the factory, all contacts are normally open and can
be changed one by one, as indicated in the information
supplied with the optional extra.
The most common use of these types of ports is to provide
necessary information to file closing software.
For more information, please contact our technical service
T.S.S.
or our nearest distributor.
Installation.
Remove the protective cover from the unit's
•
Take the corresponding U.E. and insert it into the reserved slot.
•
Make sure that it is properly connected. To do so, you must
overcome the opposing resistance in the connector located in
the slot.
Make the necessary connections on the strip or connectors
•
available as applicable.
Place the new protective cover supplied with the interface to
•
relays card and fix it using the same screws that previously
fixed the original cover.
5.3.6.7. IoT.
See the NIMBUS Cloud (EL284*50) manual.
See the NIMBUS card manual (EL139*01).
5.3.6.8. WiFi connection (optional).
The WLAN Dongle module (Fig. 12) (wireless) is optional, please
contact the distributor for more details.
74
5.4. SOFTWARE.
Download of free WinPower software.
WinPower is a UPS monitoring software which provides a user-
friendly interface for monitoring and control. It features an auto
shutdown function for systems consisting of several PCs in
case of power failure. The software enables users to monitor
and control any UPS in the same LAN through an RS232 or USB
communications port, regardless of how far away they are from
each other.
Fig. 55. View of WinPower's main screen.
Installation procedure:
intelligent
slot.
Go to the web page:
•
http://support.salicru.com
•
Select the required operating system and follow the instructions
•
described on the web page to download the software.
When the download is complete, enter the activation number
•
511C1-01220-0100-478DF2A
Once the installation is complete, restart the PC. The
•
WinPower software will appear as a green plug located on the
desktop near the clock.
to install the software.
SALICRU