Télécharger Imprimer la page

Dimplex XLF60 Manuel De L'utilisateur page 13

Publicité

Les langues disponibles

Les langues disponibles

Fireplace Installation (continued)
240V Installation
CAUTION: Use the appropriate
wire to meet local and national
electrical codes for rated power
consumption.
To 240V direct wire:
1. Connect the L1 wire from the
unit to the L1 wire from the
power supply with a wire nut.
2. Connect the L2 wire from the
unit to the L2 wire from the
power supply with a wire nut.
3. Connect the N wire from the
unit to the neutral wire from the
power supply.
4. Connect the G wire from the
unit to the ground wire from the
power supply with a wire nut
or attach the grounding wire
to the cover with the provided
grounding screw, by placing the
wire in-between screw and lock
washer and tighten (Figure 3).
5. Ensure that all wires are secure
and do not protrude past the
flame panel, so as not to be
visible after final assembly.
6. Continue to the final assembly
instructions.
Bathroom Use
If this unit is installed in a bathroom
it must be protected by a GFI
receptacle or circuit. If receptacle is
used it must be readily accessible.
To prevent electrical shock this
unit is an electrical appliance
that is NOT watertight and must
be installed as to prevent water
from entering unit. This must be
installed away from showers, tubs,
etc. Never locate fireplace where
it may fall into a bathtub or other
water container.
Final Assembly
1. Locate and remove the screws
securing the partially reflective
glass bracket to the unit
(Figure 7), along the top of the
opening, and set bracket and
screws aside.
2. Remove the provided suction
cup from the inside cavity of the
unit.
3. Before installation ensure that
the front glass and the partially
reflective glass are clean.
Particles can be removed by
dusting lightly with a clean dry
cloth. To remove fingerprints
13

Publicité

loading