Télécharger Imprimer la page

CAME OPS Serie Manuel D'installation, D'utilisation Et D'entretien page 45

Publicité

Les langues disponibles

Les langues disponibles

ADJUSTING THE TRIMMERS
A.C.T.
SP. SLOW
_
+
+
Trimmer
Description of functions
Automatic Closing Time
A.C.T.
It sets the open gate's waiting time. Once this time elapses, the shutter automatically closes.
The waiting time can be adjusted to between 1 and 120 s.
Slow-down speed
SP. SLOW
It adjusts the gearmotors' speed when slowing down.
The speed can be adjusted from 30% (-) to 60% (+) of maximum speed.
Sensibility
SENS.
It adjusts the obstruction detection sensitivity during gate movement.
Minimum sensitivity (-) or maximum sensitivity (+).
ALERT LED
LEDs
Description
CX (Yellow)
It warns that contact 2-CX (NC) is open (photocells)
1 (Yellow)
It warns that contact 1-2 (NC) is open (STOP button)
3P (Yellow)
It warns that contact 2-3P (NO) is closed (partial opening button)
7 (Yellow)
It warns that contact 2-7 (NO) is closed (command button)
It warns about the features' programming phases, the automatic closing waiting time and of any errors/
PROG (Red)
malfunctions
PWR (Green)
It warns about the voltage present in the control board
SENS.
_
_
+
A.C.T.
SP.SLOW
CX
SENS.
1
3P
7
PRG
PWR