COMMAND AND CONTROL DEVICES
⚠ WARNING! For the system to work properly, before fitting any plug-in card, such as the AF or R800 one, you
MUST CUT OFF THE MAINS POWER SUPPLY and, if present, disconnect any batteries.
Connector for the R800 card (the
R800 card is for using the keypad
selector)
To be able to snap in the cards into the dedicated connectors, raise the card cover.
Blue
White
Antenna RG58 cable for remote control
Connector for AF card (AF868 or AF43S) for remote control
R800
OPEN-CLOSE-INVERT function (step-step) from
control device (NO contact). Alternatively, from
functions programming you can activate the
OPEN-STOP-CLOSE-STOP command.
PARTIAL OPENING feature from command device
(NO contact).
STOP STOP(N.C. contact). For stopping the gate
while excluding automatic closing. To resume mo-
vement press the control button or use another
control device.
If unused, it should be deactivated during pro-
gramming.