Automatic closing after partial stop
By default, the feature is enabled.
To disable it:
select the DIP switches as shown and press the P1 key on the card. The LED blinks and the buzzer
sounds off twice.
To return to the default setting, press P1 again. The LED stays on and the buzzer sounds off for 1 s.
⚠ When the feature is disabled, after an opening command, the gate automatically closes until the
previously set partial opening point.
To completely close the gate send a 2-7 command from a button or transmitter.
Services test
By default, the feature is disabled.
To enable it:
select the DIPs as shown and press the P1 key on the control board. The LED stays on and the buzzer
sounds off for one second.
To return to the default setting, press P1 again. The LED blinks and the buzzer sounds off twice.
Obstruction detection with motor stopped
By default, the feature is disabled.
To enable it:
Select the DIP switches as shown and press the P1 key on the control board. The LED stays on and the
buzzer sounds off for one second.
To return to the default setting, press P1 again. The LED blinks and the buzzer sounds off twice.
Encoder
By default, this function is enabled.
To disableit:
select the DIP switches as shown and press the P1 key on the control board. The LED blinks and the
buzzer sounds off twice.
To return to the default setting, press P1 again. The LED stays on and the buzzer sounds off for 1 s.
Button-activated maintained action
By default, the feature is disabled.
To enable it:
select the DIPs as shown and press the P1 key on the control board. The LED stays on and the buzzer
sounds off for one second.
To return to the default setting, press P1 again. The LED blinks and the buzzer sounds off twice.
⚠ The gate opens and closes when the button is kept pressed.
Opening button connected on 2-3P (NO contact) and closing button connected on 2-7 (NO contact)
All other control devices, even radio-based ones, are excluded.
Pre-flashing (pre-flashing duration: 5 s)
By default, the feature is disabled.
To enable it:
select the DIPs as shown and press the P1 key on the control board. The LED stays on and the buzzer
sounds off for one second.
To return to the default setting, press P1 again. The LED blinks and the buzzer sounds off twice.
Adjusting the maneuver speed
The defaultmaneuver speed is set to 100%.
To diminish the maneuver speed by 40%:
select the DIP switches as shown and press P1 on the control board. The red LED stays lit and buzzer
sounds off for one second.
To return to the default setting, press P1 again. The LED blinks and the buzzer sounds off twice.