Time
Ramp time
before the
Error
before
error
code
signalling of
is taken into
error
account after
signalling
E11
~5s
300s
E12
0s
0s
E19
0s
0s
E---
0s
0s
Example of
error page
Installation and operating instructions –
Waiting time
Max.
before
error in
automatic
24 h
reactivation
0 s if error deleted
6
Un
0 s if error deleted
limited
Un
0 s if error deleted
limited
Unlimited
1
Helix EXCEL 2461016
Faults
Possible causes
The motor intensity is higher
than the maximum intensity
allowed by the drive
Motor speed too high, almost
120% of the speed max.
The pump tries to start unsuc-
cessfully while switching
direction
Internal defect of the converter Call the after-sales technician.
10.2 Errors acknowledgement
CAUTION! Risk of property damage!
Only acknowledge errors after they have been
resolved.
• Errors may be resolved by qualified
technicians only.
• When in doubt, contact the manufacturer.
• In case of a error, the malfunction page is dis-
played instead of the status
• To acknowledge a error, proceed as
follows.
• Press the rotary knob.
• The following information appears in the display:
• Menu number <6.0.0.0>.
• Malfunction number and maximum number
during the 24 hours of the error occurrence (e.g.
1/6).
• The time remaining until the error is reset auto-
matically in seconds.
• Wait for the auto reset time to elapse.
A timer runs inside the system. The remaining
time (in seconds)
until the error is automatically
acknowledged is displayed.
• When the maximum number of error is reached
and the last follow-up time has elapsed, press
the rotary knob to acknowledge.
The system returns to the status page.
NOTICE: If time for the resolution of the mal-
function remains after the error signal
(e.g.: 300 s), then the error must always be
acknowledged manually.
The auto reset timer is inactive and " "
is
displayed.
Remedies
Density and/or viscosity of the
pumped fluid too high. Check if the
pump is not obstructed by foreign
bodies.
The pump takes back its normal
speed.
Check the impermeability of the
valve.
page.
:
Example of
status page
English
Waiting
time
before
reset
0s
0s
60s
60s
67