English
Input/output connections
Remote control: Position [C1]
• Converter delivered with a jumper.
• Use of the remote control is optional
External signal IN2: Position [C2]
• 2 wires ([20 mA/10 V] / 0 V )
IN1 sensor: Position [C3]
• 2 wires ([20 mA/10 V] / +24 V )
• 3 wires ([20 mA/10 V] / 0 V / +24 V)
IN1 and IN2 sensors: Position [C4]
• 2 wires ([20 mA/10 V] / +24 V)
• 3 wires ([20 mA/10 V] / 0 V / +24 V)
50
Aux
Ext. Off
MP
20 mA/10
IN2
Remote
control
Aux
Ext. Off
MP
20 mA/10
IN2
External
signal
Aux
Ext. Off
MP
20 mA/10
IN2
Ext. Off
Aux
MP
20 mA/10
IN2
IN2 sensor
DDG
GND
IN1
GND
+24 V
DDG
GND
IN1
GND
+24 V
DDG
IN1
GND
GND
+24 V
Sensor
DDG
GND
IN1
GND
+24 V
IN1 sensor