4.7 Remote control
The remote control works with the settings made in the control panel and allows stove lighting-shutdown, and
adjustment of the required output and temperature.
Since this device transmits through an infrared diode, it must be pointed at the receiver unit in the control panel.
The remote control allows the following operations:
P5 - COMFORT function: pressing this button forces power and ventilation onto P1. Deactivating this function will
take the power and ventilation to the value prior to activation.
This function observes and performs STANDBY.
P6 - QUICK function: pressing this button forces the machine power onto P5, saving the previous set power.
Ventilation, too, if present, is forced onto AUTOMATIC (so maximum ventilation); saving the previous ventilation
value. When pressed with the comfort function activated, it restores power and ventilation to the previous saved
value. With set ambient or set water satisfied the heater modulates P1 power together with ventilation.
P7 - MAGIC CLEANING function: pressing this button while the machine is working will force BRAZIER CLEANING.
When OFF, activating this function will put the machine into FINAL CLEANING. From the state of FINAL CLEANING,
if this button is pressed again it will discharge the FINAL CLEANING timer thus leaving intact the safety checks on the
flue gas temperature.
P8 - TURBO function: like the QUICK function with the difference that the heater does not modulate P1 power with
set ambient or set water satisfied but modulates only in the flue gas safety condition.
4.7.1 Replacing the battery
The remote control is powered by a 3-volt CR2025 type battery located in the bottom of the device. For its insertion
and possible replacement, proceed as follows:
- operate the lever indicated;
- pull out the battery tray completely and replace the battery (3-volt CR2025 model)
respecting the polarity;
- insert the tray;
- check proper operation with the unit running.
- Keep the remote control away from direct heat sources and water.
- The batteries of the remote control must be replaced and disposed of separately
in special containers in a safe way in accordance with local environmental regulations.
4.8 Thermostat - external chronothermostat
The standard unit controls the room temperature by means of a digital probe that adjusts the power according to the
set temperature.To use an additional thermostat, contact an authorised technician and proceed as follows:
turn off the power at the main switch (if available) and disconnect the power cable;
remove the panels to gain access to the main board;
referring to the wiring diagram, connect the two thermostat wires to the respective terminals TERM on the
board (use a 'normally open' type thermostat);
refit everything and check proper functioning
Then set as follows:
external thermostat: set a temperature of 7°C;
external chronothermostat: set a temperature of 7°C, disable the chrono functionality in the menu 03 and
set the STANDBY function to ON. When the set temperature is reached, the stove will shut down and not
go to modulation.
In this case, however, it is advisable to use the stove time programming function and only the external
chronothermostat set temperature function.In fact, only with this joint setting is it possible to set STANDBY
to ON or OFF, obtaining respectively modulation or shutdown when the SET temperature is reached and
likewise obtaining shutdown and lighting according to the set time programming.
When the external thermostat requests stove operation, the corresponding symbol will light up on the display.
battery tray
lever
41