FAULT MESSAGES FROM THE DIGITAL CONTROLS (E2)
ERROR
14
Supply voltage
E2 →
LIN version compatibi-
20
E2 →
lity
E2 →
XX
Unknown error
For the all other issues please contact authorized costumer service.
ERROR CODES OF THE COIL MODULE (E4)
ERROR
FAULT
Initialization error
E4 → 01
Overtemperature
E4 → 02
in coil
E4→ 03
Allocation error
E4 → 04
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
FAULT
Problem with the keybo-
ard supply voltage
Incompatible LIN ver-
sion
Unknown cause for the
error
CAUSE
System setup not OK
LIN/CAN bus wiring
damaged
LIN Knob damaged
Coil temperature too
high
Coil temperature sen-
sor damaged
DIP switches for ad-
dress settings wrong
configured
- 21 -
MAINTENANCE
CAUSE
Call technical authorized
service
INTERVENTION
Check system setup according
to the installation instructions
Check cabling
Check and replace LIN Knob
Switch off cooking zone, remo-
ve cookware and wait for cool-
down of the cooking zone
Replace coil temperature
sensor
Check and correct configu-
ration
INTERVENTION