ERROR
E1 → 05
Overcurrent in Coil
Overvoltage in DC coil
06
E1 →
circuit
0
Undervoltage
E1 →
7
0
No coil current detected
E1 →
8
09
E1 →
Overcurrent in coil
10
Internal error
E1 →
E1 →
LIN bus communication
11/12
error
13
Error in Coil Module
E1 →
No communication with
14
E1 →
Coil Module
No communication with
15
E1 →
cooking zone
16
CAN bus error
E1 →
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
FAULT
Coil damaged
Generator damaged
Mains voltage too high
Coupling between 2 coils
due to unsuitable co-
okware
Line fuse blown / missing
phase
Mains voltage too low
Coil damaged or not con-
nected properly
Generator damaged
Unsuitable cookware
Wrong or defective coil
Internal
MOD1 Generator
LIN bus wiring damaged
LIN subscriber (e. g. LIN
Knob) damaged
Coil ID damaged / not
plugged properly
Coil Module damaged
CAN bus cabling dama-
ged
Coil Module damaged
DIP switches for address
settings wrong configured
CAN bus cabling dama-
ged
CAN bus not terminated
properly
Interferences in CAN
bus due to bad ground
connection
- 19 -
MAINTENANCE
CAUSE
Check resistance of coil;
replace if necessary
Contact customer support
Check mains voltage
Use recommended co-
okware
Check presence of all 3
phases
Check grid
Verify coil connection and
check resistance of the
coil
Use recommended co-
okware
Check coil, replace if ne-
cessary
error
inside
Contact customer
port
Replace damaged cabling
Replace damaged LIN
subscriber
Check/replace Coil ID
Replace Coil Module
Check
cabling
Replace Coil Module
Check and correct confi-
guration
Replace damaged cabling
Check termination at bus
end
Verify proper ground con-
nections
INTERVENTION
sup-
and
replace