C) COIL MODULE ERRORS / EXAMPLE E4
1 STEADY RED LIGHT AND
1 LONG GREEN FLASH
→ → ERROR
If the red light comes on when the appliance is switched on, try to solve it with
the help of this table.
FAULT
- Self diagnosis error / Initia-
lization error
- Empty pan
RED LIGHT
- Dirty air filter
Whenever the appliance does not work properly, try to solve the less serious
problems using this table.
ERROR CODES OF THE MOD1 GENERATOR (E1)
ERROR
E1 → 01
Initialization error
Overtemperature in in-
E1 → 02
ternal heatsink
Overtemperature inside
E1→ 03
generator
E1 → 04
Allocation error
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
+
4 MEDIUM GREEN
→ → ERROR E4
POSSIBILE CAUSE
FAULT
LIN or CAN bus cables
damaged
LIN Knob damaged
Coil Module damaged
Air duct or fat filter
blocked
Fan damaged
Internal error
Ambient temperature too
high
Fan damaged
Internal error
DIP switches for address
settings wrong configu-
red
- 18 -
MAINTENANCE
01
+
FLASHES
INTERVENTION
- Machine reset / Turn knob to "zero"
(switch off), wait 5 minutes and switch
on again
- Remove the pan and switch off the
hob
- Clean air filter (see chapter Mainte-
nance / Air filter Cleaning
CAUSE
1 SHORT GREEN FLASH
→ → FAULT 1
INTERVENTION
Check cabling
Replace LIN Knob
Replace Coil Module
Contact customer support
Clean filter/air duct
Replace fan
Contact customer support
Reduce ambient tempe-
rature
Replace fan
Contact customer support
Check and correct confi-
guration