EN 61000-6-3
Electromagnetic compatibility (EMC) – Part 6-3:
Generic standards – Emission standards for
residential, commercial and light-industrial
environments.
EN ISO 5801
Fans – Performance testing using standardized
airways.
EN 13142
Ventilation for builings – Components/Products
for residential ventilation – required and
optional performance characterisics.
EN 14121
Aluminium and aluminium alloys – Sheet, strip
and plate for electrotechnical applications.
Skinnskattberg 2019-12-13
Sofia Rask
Managing Director
202341 | A021
Safety Information
This machinery must not be put into operation
prior to reading mounting instructions and
safety information.
All fans are intended for transportation of air in
air handling systems. If installed in non-heated
rooms, the fan casing has to be insulated in
order to avoid condensation. They are meant
for use once built into machinery or ducted
systems and after a protection grid has been
installed. (EN ISO 13857). Fans with duct
connections must be connected to ducts on
both sides (inlet/outlet). No moving parts shall
be accessible after installation. The fans are not
to be used in hazardous environments or
connected to flue ducts. The fans must not be
installed outdoors, (with exception of roof fans
and fans with, for this purpose, with
corresponding IP class). Fans installed without
insulation in non-heated areas bear a risk a risk
of condensation. Safety accessories (i.e. motor
protection, safety grille) may not be removed,
short-circuited or disconnected. Roof fans are
exclusively intended for extract air applications.
This appliance can be used by children aged
from 8 years and above and persons with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they
have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved. Children
shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
Precautions must be taken to prevent the
backflow of exhaust gases from flues from other
appliances installed in the same room, which
are fired by gas or other fuels.
The appliance must be connected to a mains
circuit breaker in the fixed installation.
Install a circuit breaker in the permanent
electrical installation, with a contact opening of
at least 3 mm at each pole.
CAUTION!
- Before servicing or maintenance, switch off
power, (all-pole circuit breaker), and make
sure the impeller has come to standstill.
EN