Installation Instructions
Installation Check List
Is the Ice Machine level?
Has all of the internal packing been
removed?
Have all of the electrical and water
connections been made?
Has the supply voltage been tested and
checked against the rating on the nameplate?
Is there proper clearance around the ice
machine for air circulation?
Is the ice machine grounded and polarity
correct?
Has the ice machine been installed where
ambient temperatures will remain in the
range of 50° - 110°F (10° - 43°C)?
Has the ice machine been installed where the
incoming water temperature will remain in the
range of 35° - 90°F (2° - 32°C)?
Is the ice machine drain line routed to an
open site drain?
Are all electrical leads free from contact with
refrigeration lines and moving equipment?
Has the owner/operator been instructed
regarding maintenance and the use of
Manitowoc Cleaner and Sanitizer?
Has the OWNER WARRANTY
REGISTRATION CARD been completed?
Has the ice machine and bin been sanitized?
10
When installed is the drain pump functioning
correctly energizes, de-energizes and safety
switch stops the ice machine?
GFCI Required - Is it a breaker type and not a
receptacle type?
Is the ice machine plugged into a properly
grounded, polarized receptacle?
Have the water and drain connections been
examined for leaks?
NOTE: If air temperature is less than 60°F (15.5°C), water
temperature must be equal to or greater than 50°F (10°C).
Before Starting the Ice Machine
Sanitize the ice machine.
All Manitowoc ice machines are factory-operated and
adjusted before shipment. Normally, new installations do
not require any adjustment.
To ensure proper operation, follow the Operational
Checks in Section 3 of this manual. Starting the ice
machine and completing the Operational Checks are the
responsibilities of the owner/operator.
Adjustments and maintenance procedures outlined in
this manual are not covered by the warranty.
!
Potential Personal Injury Situation
Do not operate equipment that has been misused.
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications.
Section 2
Warning
Part Number 040001361 05/10