TECHNICAL DATA
MODEL
TYP
OUTPUT
(1)
FUEL
- net calorific value
- absolute density
- max. delivery
- pressure at max. delivery
(2)
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR IE3
Running current
Start-up current
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH DIRECTIVES
NOISE LEVELS
(3)
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m s.l.m.
(2) Pressure at test point 17)(A)p.8, with zero pressure in the combustion chambre and at maximum burner output.
(3) Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
COUNTRY
SE - FI - AT - GR - DK - ES - GB - IT - IE - PT - IS - CH - NO
VARIANTS
Burner
code
20006048
20006069
2nd stage
Mcal/h
(MIN.-MAX.)
1st stage
Mcal/h
(MIN.)
kWh/Nm
Mcal/Nm
kg/Nm
°C max
V1 - V2
W max
DE
NL
FR
BE
LU
Blast tube lenght
mm
373
503
kW
kW
NATURAL GAS: G20 - G21 - G22 - G23 - G25
3
3
3
3
Nm
/h
mbar
• On-Off (1 stop min each 24 hours).
• Progressive two-stage or modulating by kit (see ACCESSOIRES).
Boilers: water, steam, diathermic oil
°C
V
3 ~ 380/220 V - 1 ~ 220 V +/-10%
Hz
rpm
W
V
A
A
A
I1 - I2
2016/426 - 2006/42 - 2014/35 - 2014/30
dBA
CATEGORY
I
2H
I
2ELL
I
2L
I
2Er
I
2E(R)B
I
2E
6
RS 160/M BLU
843 T80
930 - 1860
800 - 1600
300
258
G20
G25
10
8.6
8.6
7.4
0.71
0.78
186
216
18
24
0 - 40
60
60 Hz
3500
4000
220 / 380
13.5 - 7.8
15.8 - 9.1
126 - 72.8
230 V - 1 x 8 kV
1 A - 20 mA
4300
IP 44
80.5