Close the leaf fully and turn the other cam anti-clockwise until the closing microswitch is activated. Secure the cam with the screws.
Closing microswitch
Electrical connections
For electrical connection operations, use the chamber and the junction boxes.
For further information regarding functions and adjustment, refer to the technical documentation for the control panel.
M1 N1 E1 + E - M2 N2 E2 + E -
M
N
+
E
-
002ZLJ14 control panel terminal block
M N E + E -
002ZLJ24 control panel terminal block
24 V DC gearmotor with
delaying opening action
24 V DC gearmotor with
delaying closing action
-
E
+
N
M