GENERAL INSTALLATION INSTRUCTIONS
⚠ Installation must be carried out by qualified and experienced personnel in compliance with applicable regulations.
Preliminary checks
⚠ Before starting installation:
• Provide a suitable single-pole disconnection device, with a maximum of 3 mm between the contacts, to disconnect the power supply ;
• Prepare suitable piping and ducts for routing the electrical cables, ensuring protection against mechanical damage ;
•
Make sure that any connections within the container (made to ensure the continuity of the protection circuit) are fitted with additional insulation
compared to the other internal conductor parts;
•
Make sure the gate structure is sturdy enough, that the hinges are in proper working order and that there is no friction between the moving and fixed
parts;
•
Make sure there are opening and closing mechanical stops.
Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with current standards and
regulations. The figure shows some examples of installer's tools.
Types of cables and minimum thicknesses
Connection
230 VAC board power supply
24 VDC motor power supply
Flashing light
Photocell transmitters
Photocell receivers
Control and safety devices
Antenna
Encoder
N.B.: If the cables differ in length compared to what is shown in the table, the cable cross-section is determined according to the actual current draw of the
devices connected and according to the provisions of the IEC EN 60204-1 standard.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and distances. When
connecting products that are not specified in this manual, please refer to the documentation provided with said products.
Cable length
Cable type
1 < 10 m
2
3G x 1.5 mm
2
2G x 1.5 mm
FROR CEI
2
2 x 1.5 mm
20-22
2
IEC EN
2 x 0.5 mm
50267-2-1
2
4 x 0.5 mm
2
2 x 0.5 mm
RG58
TWISTED
Cable length
10 < 20 m
2
3G x 1.5 mm
3G x 2.5 mm
2
2G x 1.5 mm
2G x 2.5 mm
2
2 x 1.5 mm
2 x 1.5 mm
2
2 x 0.5 mm
2 x 0.5 mm
2
4 x 0.5 mm
4 x 0.5 mm
2
2 x 0.5 mm
2 x 0.5 mm
max. 10 m
max. 30 m
Cable length
20 < 30 m
2
2
2
2
2
2