⚠ Caution: if there are no end stops, end runs must be fitted.
Securing the end runs and determining the end run points
For left-hand gearmotor.
Secure the end run to the gearmotor and insert the cams on the guide.
UNI6957 Ø2.9X19 screw
Cams
End run
Cam guide
Close the leaf fully and turn the cam anti-clockwise until the closing microswitch is activated. Secure the cam with the screws.
Closing microswitch
Fully open the leaf and turn the other cam clockwise until the opening microswitch is activated. Secure the cam with the screws.
Opening mi-
croswitch