8. TRANSPORTATION & STORAGE
Draining the Fuel Tank
< < 31> >
1.
Turn OFF the engine. Remove the fuel cap and the debris screen
underneath the fuel cap.
2.
Empty the fuel tank using a siphon and an approved gasoline container.
3.
Start the generator and let it run until it stops and all remaining fuel is
consumed. Do not plug in any appliances during this process.
4.
Rotate the fuel cap vent to ON, turn the power knob to OFF, and loosen the
carburetor drain bolt to discharge all gasoline from inside of the carburetor.
5.
Once all the fuel has drained tighten the carburetor screw and after the
engine has completely cooled turn the fuel cap vent to OFF.
Transporting the Generator
1.
Do not overfill the fuel tank (No residual fuel on the neck of tank).
2.
Do not use the generator in the vehicle. The generator should ONLY be
used while in a well ventilated area.
3.
Avoid exposing the generator to prolonged direct sunlight while in an
enclosed vehicle. The high temperature inside the vehicle could cause fuel
to vaporize resulting in a possible explosion.
4.
Drain the generator of fuel and oil before being transported on rough roads.