2.3 CONTROL FUNCTIONS
AC Circuit Breaker
While the generator is running, the breaker should be put in the ON
position.
If the current has exceeded its limits it will automatically pop out to the
OFF position. Reduce the electrical load on the generator and push the
button back to the ON position..
AC Parallel Port (If Equipped)
This socket allows two compatible Energizer i-series inverter generators
to be connected for additional power. The parallel kit is an optional
accessory, please visit us online to purchase.
EcoMode (Economy Control Switch)
Turn EcoMode ON to minimize fuel consumption. In this mode the
engine will dynamically meet the demand of the electrical load and will
automatically go into an idle state if all loads are disconnected.
Before connecting or removing a high load device to the generator, turn
EcoMode OFF until that device has reached running power.
When EcoMode is OFF, the engine runs at full speed.
Output and Overload Indicator
In normal operation, the green output indicator light (READY TO USE)
will remain on.
If the generator is overloaded (producing more than 1800W) or a
connected appliance has short-circuited, the output indicator light will
turn off and the overload indicator light will turn on.
Low Oil Indicator Light
The oil alert system is designed to prevent engine damage caused by
an insufficient amount of oil in the crankcase. Before the oil level in the
crankcase reaches an unsafe limit, the oil alert system will automatically
shut down the engine (the power switch remains in the ON position).
If the oil alert system shuts down the engine, the low oil indicator light
(red) will turn on. Check the engine oil level.
DC Circuit Breakers
The DC circuit breaker automatically shuts off when the charging circuit
is overloaded.