Télécharger Imprimer la page

Franke FHM 301 1TC Conseils D'utilisation Et D'installation page 19

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Technical data
Appliance cat. II 2H3+
Type of gas
Burner
Natural gas
auxiliary
(methane)
G20
triple crown
20 mbar
Liquified
auxiliary
petroleum gas
(LPG)
triple crown
G30-G31
30/37 mbar
Burner
Auxiliary
Rapid
Triple crown
The use of larger pots than those specified can cause excessive overheating of the knobs and top.
Franke declines any liability for damage due to such incorrect use.
Total heat capacity: see dataplate on the bottom of the hob.
Air necessary for combustion: 2 m
Power supply voltage 220/240 V 50-60 Hz.
The appliance complies with the following EEC Directives:
– 90/396/EEC (Gas):
– 73/23/EEC dated 19/02/73 (Low Voltage);
– 89/336/EEC dated 03/05/89 (Electromagnetic Compatibility);
– 93/68/EEC dated 22/07/93 as amended.
18
All manuals and user guides at all-guides.com
Injector
marking
72
rapid
115
140
50
rapid
85
91
Table of recommended pots
3
/h per kW of installed power - see dataplate.
Heat
Rated heat
capacity
capacity
reduced
in kW
in kW
1.000
0.380
3.000
0.800
3.300
1.600
1.000
0.380
3.000
0.800
1.600
3.300
Ø Pots in cm
from Ø 8 to Ø 14
from Ø 22 to Ø 24
from Ø 24 to Ø 28
Rated
consumption
3
0.095 m
/h
3
0.286 m
/h
3
0.314 m
/h
73 g/h
218 g/h
240 g/h

Publicité

loading

Ce manuel est également adapté pour:

Fhm 302 2g