Power supply
230 V AC, 50/60 Hz
Eyelet terminal with
screw and washer
for grounding
connection.
230V AC motor
Signaling devices
230 V AC output for flashing light:
- It flashes when the boom is raising or lowering.
Barrier raised alert light (contact rated for 24V - 3W max.)
- It alerts when the barrier is raised, and turns off when the boom is lowered.
Barrier closed alert light (contact rated for 24V - 3W max.)
- It alerts when the barrier is lowered, and turns off when the barrier is raised.
Brown
Black
Blue
Terminals for powering up accessories:
- a 24 V AC normally;
Overall allowed power: 40 W
Orange
COM
NC
Orange
COM
NC
Opening micro-
switch (F-FA)
Closing micro-switch
(F-FC)